The DOI matches its Crossref record.
If You Don’t Find It Often, You Often Don’t Find It: Why Some Cancers Are Missed in Breast Cancer Screening
Open accessAbstract
Mammography is an important tool in the early detection of breast cancer. However, the perceptual task is difficult and a significant proportion of cancers are missed. Visual search experiments show that miss (false negative) errors are elevated when targets are rare (low prevalence) but it is unknown if low prevalence is a significant factor under real world, clinical conditions. Here we show that expert mammographers in a real, low-prevalence, clinical setting, miss a much higher percentage of cancers than are missed when the mammographers search for the same cancers under high prevalence conditions. We inserted 50 positive and 50 negative cases into the normal workflow of the breast cancer screening service of an urban hospital over the course of nine months. This rate was slow enough not to markedly raise disease prevalence in the radiologists' daily practice. Six radiologists subsequently reviewed all 100 cases in a session where the prevalence of disease was 50%. In the clinical setting, participants missed 30% of the cancers. In the high prevalence setting, participants missed just 12% of the same cancers. Under most circumstances, this low prevalence effect is probably adaptive. It is usually wise to be conservative about reporting events with very low base rates (Was that a flying saucer? Probably not.). However, while this response to low prevalence appears to be strongly engrained in human visual search mechanisms, it may not be as adaptive in socially important, low prevalence tasks like medical screening. While the results of any one study must be interpreted cautiously, these data are consistent with the conclusion that this behavioral response to low prevalence could be a substantial contributor to miss errors in breast cancer screening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rodriguez-Ruiz, A., Lång, K., Gubern-Merida, A., Broeders, M., Gennaro, G., Clauser, P., Helbich, T. H., Chevalier, M., Tan, T., Mertelmeier, T., et al. (2019) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djy222 · Cited by 692
Detection of Breast Cancer with Mammography: Effect of an Artificial Intelligence Support System
Rodríguez-Ruiz, A., Krupinski, E., Mordang, J.-J., Schilling, K., Heywang-Köbrunner, S. H., Sechopoulos, I., & Mann, R. M. (2019) · Radiology · doi:10.1148/radiol.2018181371 · Cited by 602
Lång, K., Josefsson, V., Larsson, A.-M., Larsson, S., Högberg, C., Sartor, H., Hofvind, S., Andersson, I., & Rosso, A. (2023) · The Lancet Oncology · doi:10.1016/s1470-2045(23)00298-x · Cited by 598
Lotter, W., Diab, A. R., Haslam, B., Kim, J. G., Grisot, G., Wu, E., Wu, K., Onieva, J. O., Boyer, Y., Boxerman, J. L., et al. (2021) · Nature Medicine · doi:10.1038/s41591-020-01174-9 · Cited by 423
Suboptimality in perceptual decision making
Rahnev, D., & Denison, R. N. (2018) · Behavioral and Brain Sciences · doi:10.1017/s0140525x18000936 · Cited by 342
Metadata
- Authors
- Evans, K. K., Birdwell, R. L., & Wolfe, J. M.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2013-05-30
- Volume
- 8
- Issue
- 5
- Pages
- e64366
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2106028737
- Cited by
- 236
- References
- 0
- FWCI
- 8.32
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: If You Don’t Find It Often, You Often Don’t Find It: Why Some Cancers Are Missed in Breast Cancer Screening. https://app.cochat.ai/papers/10.1371/journal.pone.0064366
- The paper
- Evans, K. K., Birdwell, R. L., & Wolfe, J. M. (2013). If You Don’t Find It Often, You Often Don’t Find It: Why Some Cancers Are Missed in Breast Cancer Screening. PLoS ONE. https://doi.org/10.1371/journal.pone.0064366
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.