Type of Mask May Impact on Continuous Positive Airway Pressure Adherence in Apneic Patients
Open accessThe DOI matches its Crossref record; 45 of the 47 references it cites were found in a registry or an index.
Abstract
RATIONALE: In obstructive sleep apnea patients (OSA), continuous positive airway pressure (CPAP) adherence is crucial to improve symptoms and cardiometabolic outcomes. The choice of mask may influence CPAP adherence but this issue has never been addressed properly. OBJECTIVE: To evaluate the impact of nasal pillows, nasal and oronasal masks on CPAP adherence in a cohort of OSA. METHODS: Newly CPAP treated OSA participating in "Observatoire Sommeil de la Fédération de Pneumologie", a French national prospective cohort, were included between March 2009 and December 2011. Anthropometric data, medical history, OSA severity, sleepiness, depressive status, treatment modalities (auto-CPAP versus fixed pressure, pressure level, interface type, use of humidifiers) and CPAP-related side effects were included in multivariate analysis to determine independent variables associated with CPAP adherence. RESULTS: 2311 OSA (age = 57(12) years, apnea+hypopnea index = 41(21)/h, 29% female) were included. Nasal masks, oronasal masks and nasal pillows were used by 62.4, 26.2 and 11.4% of the patients, respectively. In univariate analysis, oronasal masks and nasal pillows were associated with higher risk of CPAP non-adherence. CPAP non-adherence was also associated with younger age, female gender, mild OSA, gastroesophageal reflux, depression status, low effective pressure and CPAP-related side effects. In multivariate analysis, CPAP non-adherence was associated with the use of oronasal masks (OR = 2.0; 95%CI = 1.6; 2.5), depression, low effective pressure, and side effects. CONCLUSION: As oronasal masks negatively impact on CPAP adherence, a nasal mask should be preferred as the first option. Patients on oronasal masks should be carefully followed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“While data from a total of 4563 individuals with OSA was included, the majority of the data came from a single study.1061”
From International Consensus Statement on Obstructive Sleep Apnea (2023) · cites this paper as [1061]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe cited source doesn’t support the claim as written.
In the citing paper
“In these non-RCT cohorts, oronasal interfaces were least often chosen by participants for long-term treatment compared with nasal and intra-nasal interfaces.249,250”
From Treatment of Adult Obstructive Sleep Apnea With Positive Airway Pressure: An American Academy of Sleep Medicine Systematic Review, Meta-Analysis, and GRADE Assessment (2019) · cites this paper as [249]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Oronasal mask users were more likely than the other groups to report side effects and to find CPAP inconvenient.”
From International Consensus Statement on Obstructive Sleep Apnea (2023) · cites this paper as [1061]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This also demonstrated a clinically significant difference in adherence of 0.7 h/night (95% CI: 0.2 to 1.2 h/night) in favor of nasal interfaces (see supplemental material, Figure S97).”
From Treatment of Adult Obstructive Sleep Apnea With Positive Airway Pressure: An American Academy of Sleep Medicine Systematic Review, Meta-Analysis, and GRADE Assessment (2019) · cites this paper as [249]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In the non-RCTs, oral interfaces were associated with significantly more upper airway dryness and”
From Treatment of Adult Obstructive Sleep Apnea With Positive Airway Pressure: An American Academy of Sleep Medicine Systematic Review, Meta-Analysis, and GRADE Assessment (2019) · cites this paper as [249]
Experimental — accuracy not yet measured
3 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
CPAP for the Metabolic Syndrome in Patients with Obstructive Sleep Apnea
Sharma, S. K., Agrawal, S., Damodaran, D., Sreenivas, V., Kadhiravan, T., Lakshmy, R., Jagia, P., & Kumar, A. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103944 · Cited by 369 · cited 1×
“Both randomized controlled studies and observational cohort studies have demonstrated beneficial effects in terms of cardiovascular [2,3,4,5], metabolic [6], daytime vigilance and quality of life [7] outcomes.”
BackgroundRetractedA New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness Scale
Johns, M. W. (1991) · Sleep · doi:10.1093/sleep/14.6.540 · Cited by 17,364
Marin, J. M., Carrizo, S. J., Vicente, E., & Agusti, A. G. (2005) · The Lancet · doi:10.1016/s0140-6736(05)71141-7 · Cited by 4,678 · cited 2×
“This is a common concern for many prospective observational cohorts [2,3].”
BackgroundSullivan, C., Berthon-Jones, M., Issa, F., & Eves, L. (1981) · The Lancet · doi:10.1016/s0140-6736(81)92140-1 · Cited by 2,731 · cited 5×
“Continuouspositiveairwaypressure (CPAP) is the first line therapy for moderate to severe obstructive sleep apnea syndrome (OSAS) [1].”
BackgroundInfluentialWeaver, T. E., Maislin, G., Dinges, D. F., Bloxham, T., George, C. F. P., Greenberg, H., Kader, G., Mahowald, M., Younger, J., & Pack, A. I. (2007) · Sleep · doi:10.1093/sleep/30.6.711 · Cited by 1,058 · cited 2×
“A threshold of four hours of CPAP usage per night was used to separate adherent and non-adherent patients [2,4,10,11,32].”
BackgroundMethodPepperell, J. C., Ramdassingh-Dow, S., Crosthwaite, N., Mullins, R., Jenkinson, C., Stradling, J. R., & Davies, R. J. (2002) · The Lancet · doi:10.1016/s0140-6736(02)07445-7 · Cited by 1,052 · cited 1×
“Both randomized controlled studies and observational cohort studies have demonstrated beneficial effects in terms of cardiovascular [2,3,4,5], metabolic [6], daytime vigilance and quality of life [7] outcomes.”
BackgroundContinuous positive airways pressure for obstructive sleep apnoea in adults
Giles, T., Lasserson, T., Smith, B., White, J., Wright, J., & Cates, C. (2006) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001106.pub2 · Cited by 1,001 · cited 1×
“Both randomized controlled studies and observational cohort studies have demonstrated beneficial effects in terms of cardiovascular [2,3,4,5], metabolic [6], daytime vigilance and quality of life [7] outcomes.”
BackgroundKatan, M., & Van De Bovenkamp, P. (1987) · The Lancet · doi:10.1016/s0140-6736(87)91641-2 · Cited by 964
Barbé, F., Durán-Cantolla, J., Sánchez-de-la-Torre, M., Martínez-Alonso, M., Carmona, C., Barceló, A., Chiner, E., Masa, J. F., Gonzalez, M., Marín, J. M., et al. (2012) · JAMA · doi:10.1001/jama.2012.4366 · Cited by 792 · cited 1×
“A threshold of four hours of CPAP usage per night was used to separate adherent and non-adherent patients [2,4,10,11,32].”
MethodAssociation Between Treated and Untreated Obstructive Sleep Apnea and Risk of Hypertension
Marin, J. M., Agusti, A., Villar, I., Forner, M., Nieto, D., Carrizo, S. J., Barbé, F., Vicente, E., Wei, Y., Nieto, F. J., et al. (2012) · JAMA · doi:10.1001/jama.2012.3418 · Cited by 781 · cited 4×
“A threshold of four hours of CPAP usage per night was used to separate adherent and non-adherent patients [2,4,10,11,32].”
BackgroundMethodInfluential
Cited by
Patil, S. P., Ayappa, I. A., Caples, S. M., Kimoff, R. J., Patel, S. R., & Harrod, C. G. (2019) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7638 · Cited by 721
“249 In these non-RCT cohorts, oronasal interfaces were least often chosen by participants for long-term treatment compared with nasal and intra-nasal interfaces.”
InfluentialDefinition, discrimination, diagnosis and treatment of central breathing disturbances during sleep
Randerath, W., Verbraecken, J., Andreas, S., Arzt, M., Bloch, K. E., Brack, T., Buyse, B., De Backer, W., Eckert, D. J., Grote, L., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.00959-2016 · Cited by 354
Self-citationInternational Consensus Statement on Obstructive Sleep Apnea
Chang, J. L., Goldberg, A. N., Alt, J. A., Mohammed, A., Ashbrook, L., Auckley, D., Ayappa, I., Bakhtiar, H., Barrera, J. E., Bartley, B. L., et al. (2023) · International Forum of Allergy & Rhinology · doi:10.1002/alr.23079 · Cited by 350
Personalized Management Approach for OSA
Carberry, J. C., Amatoury, J., & Eckert, D. J. (2018) · Chest · doi:10.1016/j.chest.2017.06.011 · Cited by 250
Predictors of Continuous Positive Airway Pressure Adherence in Patients with Obstructive Sleep Apnea
Mehrtash, M., Bakker, J. P., & Ayas, N. (2019) · Lung · doi:10.1007/s00408-018-00193-1 · Cited by 231
Metadata
- Authors
- Borel, J. C., Tamisier, R., Dias-Domingos, S., Sapene, M., Martin, F., Stach, B., Grillet, Y., Muir, J. F., Levy, P., Series, F., Pepin, J.-L., & on behalf of the Scientific Council of The Sleep Registry of the French Federation of Pneumology (OSFP)
- Affiliations
- AGIR à dom (FR)
- Inserm (FR)
- Centre Hospitalier Compiègne-Noyon (FR)
- Centre Hospitalier de Valence (FR)
- Corresponding author
- Borel, Jean Christian
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2013-05-15
- Volume
- 8
- Issue
- 5
- Pages
- e64382
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC3654912
- OpenAlex
- W1966055642
- Semantic Scholar
- b2fb25b1e8c0d8ae8dc6ab635774963c90cd9f84
- Cited by
- 188
- References
- 47
- Citations by year
- 2026: 4 · 2025: 6 · 2024: 8 · 2023: 11 · 2022: 20 · 2021: 32 · 2020: 16 · 2019: 18 · 2018: 8 · 2017: 20 · 2016: 22 · 2015: 7 · 2014: 12 · 2013: 3
- FWCI
- 10.10
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- ResMed
- Région Normandie
- Topics
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
- Keywords
- obstructive sleep apnea, CPAP adherence, CPAP masks, oronasal mask, nasal mask, CPAP side effects, depression, effective pressure, gastroesophageal reflux, auto-CPAP
- MeSH terms
- Aged, Female, Humans, Male, Masks, Middle Aged, Patient Compliance, Prospective Studies, Sleep Apnea, Obstructive, Continuous Positive Airway Pressure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Type of Mask May Impact on Continuous Positive Airway Pressure Adherence in Apneic Patients. https://app.cochat.ai/papers/10.1371/journal.pone.0064382
- The paper
- Borel, J. C., Tamisier, R., Dias-Domingos, S., Sapene, M., Martin, F., Stach, B., Grillet, Y., Muir, J. F., Levy, P., Series, F., Pepin, J.-L., & on behalf of the Scientific Council of The Sleep Registry of the French Federation of Pneumology (OSFP). (2013). Type of Mask May Impact on Continuous Positive Airway Pressure Adherence in Apneic Patients. PLoS ONE. https://doi.org/10.1371/journal.pone.0064382
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.