Rapid Global Fitting of Large Fluorescence Lifetime Imaging Microscopy Datasets
Open accessThe DOI matches its Crossref record; 68 of the 68 references it cites were found in a registry or an index.
Abstract
Fluorescence lifetime imaging (FLIM) is widely applied to obtain quantitative information from fluorescence signals, particularly using Förster Resonant Energy Transfer (FRET) measurements to map, for example, protein-protein interactions. Extracting FRET efficiencies or population fractions typically entails fitting data to complex fluorescence decay models but such experiments are frequently photon constrained, particularly for live cell or in vivo imaging, and this leads to unacceptable errors when analysing data on a pixel-wise basis. Lifetimes and population fractions may, however, be more robustly extracted using global analysis to simultaneously fit the fluorescence decay data of all pixels in an image or dataset to a multi-exponential model under the assumption that the lifetime components are invariant across the image (dataset). This approach is often considered to be prohibitively slow and/or computationally expensive but we present here a computationally efficient global analysis algorithm for the analysis of time-correlated single photon counting (TCSPC) or time-gated FLIM data based on variable projection. It makes efficient use of both computer processor and memory resources, requiring less than a minute to analyse time series and multiwell plate datasets with hundreds of FLIM images on standard personal computers. This lifetime analysis takes account of repetitive excitation, including fluorescence photons excited by earlier pulses contributing to the fit, and is able to accommodate time-varying backgrounds and instrument response functions. We demonstrate that this global approach allows us to readily fit time-resolved fluorescence data to complex models including a four-exponential model of a FRET system, for which the FRET efficiencies of the two species of a bi-exponential donor are linked, and polarisation-resolved lifetime data, where a fluorescence intensity and bi-exponential anisotropy decay model is applied to the analysis of live cell homo-FRET data. A software package implementing this algorithm, FLIMfit, is available under an open source licence through the Open Microscopy Environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947 · cited 7×
“Considering a population of identical, randomly oriented fluorophore it may be shown [4] that the fluorescence intensity I polarised at an angle y to the excitation is given by”
BackgroundMethodInfluentialHorn, R. A., & Johnson, C. R. (1985) · Cited by 22,203
(2021) · A First Course in Statistical Programming with R · doi:10.1017/9781108993456.011 · Cited by 13,724
(2006) · Springer Series in Operations Research and Financial Engineering · doi:10.1007/978-0-387-40065-5 · Cited by 9,008
Motulsky, H. J., & Christopoulos, A. (2004) · Cited by 1,972
Topics in Fluorescence Spectroscopy
(2003) · Topics in Fluorescence Spectroscopy · doi:10.1007/0-306-47947-8 · Cited by 1,578
The Phasor Approach to Fluorescence Lifetime Imaging Analysis
Digman, M. A., Caiolfa, V. R., Zamai, M., & Gratton, E. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.120154 · Cited by 1,145
Biology of the p21-Activated Kinases
Bokoch, G. M. (2003) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.72.121801.161742 · Cited by 1,089 · cited 1×
“Rac1 [67] is a small GTPase involved in cell growth and motility, among other processes, that is known to bind Pak1 in its active form [68,69].”
BackgroundAn improved cyan fluorescent protein variant useful for FRET
Rizzo, M. A., Springer, G. H., Granada, B., & Piston, D. W. (2004) · Nature Biotechnology · doi:10.1038/nbt945 · Cited by 1,077 · cited 1×
“ECFP [11].”
Fluorescence resonance energy transfer
Clegg, R. M. (1995) · Current Opinion in Biotechnology · doi:10.1016/0958-1669(95)80016-6 · Cited by 929
Cited by
Datta, R., Heaster, T. M., Sharick, J. T., Gillette, A. A., & Skala, M. C. (2020) · Journal of Biomedical Optics · doi:10.1117/1.jbo.25.7.071203 · Cited by 880
Luminescent sensing and imaging of oxygen: Fierce competition to the Clark electrode
Wolfbeis, O. S. (2015) · BioEssays · doi:10.1002/bies.201500002 · Cited by 252
Visualising G-quadruplex DNA dynamics in live cells by fluorescence lifetime imaging microscopy
Summers, P. A., Lewis, B. W., Gonzalez-Garcia, J., Porreca, R. M., Lim, A. H. M., Cadinu, P., Martin-Pintado, N., Mann, D. J., Edel, J. B., Vannier, J. B., et al. (2021) · Nature Communications · doi:10.1038/s41467-020-20414-7 · Cited by 183
Kondo, H., Ratcliffe, C. D. H., Hooper, S., Ellis, J., MacRae, J. I., Hennequart, M., Dunsby, C. W., Anderson, K. I., & Sahai, E. (2021) · Cell Reports · doi:10.1016/j.celrep.2021.108750 · Cited by 109
“The fluorescence lifetime images of the glucose FRET biosensor were calculated using the FLIMfit software (Warren et al., 2013).”
MethodSelf-citationBazioti, V., La Rose, A. M., Maassen, S., Bianchi, F., de Boer, R., Halmos, B., Dabral, D., Guilbaud, E., Flohr-Svendsen, A., Groenen, A. G., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-31135-4 · Cited by 65
Publishing and sharing multi-dimensional image data with OMERO
Burel, J.-M., Besson, S., Blackburn, C., Carroll, M., Ferguson, R. K., Flynn, H., Gillen, K., Leigh, R., Li, S., Lindner, D., et al. (2015) · Mammalian Genome · doi:10.1007/s00335-015-9587-6 · Cited by 62
“Several examples of integrating analysis tools into OMERO have been published (Cuccuru et al. 2014; Cho et al. 2012; Devès et al. 2015; Warren et al. 2013; Swedlow et al. 2009; Leo et al. 2014).”
MethodSparks, H., Kondo, H., Hooper, S., Munro, I., Kennedy, G., Dunsby, C., French, P., & Sahai, E. (2018) · Nature Communications · doi:10.1038/s41467-018-04820-6 · Cited by 54
Self-citationAPOE genotype-dependent differences in human astrocytic energy metabolism
Budny, V., Bodenmann, C., Zürcher, K. J., Krüger, M., de Leeuw, S. M., Weber, R. Z., Rust, R., Ravotto, L., Ruminot, I., Barros, L. F., et al. (2025) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2025.1603657 · Cited by 6
“FLIM data analysis was conducted using FLIManalysis, 1 a Matlab-based wrapper of the FLIMfit library (Warren et al., 2013) designed to facilitate batch processing.”
Metadata
- Authors
- Warren, S. C., Margineanu, A., Alibhai, D., Kelly, D. J., Talbot, C., Alexandrov, Y., Munro, I., Katan, M., Dunsby, C., & French, P. M. W.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2013-08-05
- Volume
- 8
- Issue
- 8
- Pages
- e70687
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W1982478101
- Cited by
- 234
- References
- 68
- FWCI
- 7.78
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.