Improved Mass Spectrometry Assay For Plasma Hepcidin: Detection and Characterization of a Novel Hepcidin Isoform
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Mass spectrometry (MS)-based assays for the quantification of the iron regulatory hormone hepcidin are pivotal to discriminate between the bioactive 25-amino acid form that can effectively block the sole iron transporter ferroportin and other naturally occurring smaller isoforms without a known role in iron metabolism. Here we describe the design, validation and use of a novel stable hepcidin-25(+40) isotope as internal standard for quantification. Importantly, the relative large mass shift of 40 Da makes this isotope also suitable for easy-to-use medium resolution linear time-of-flight (TOF) platforms. As expected, implementation of hepcidin-25(+40) as internal standard in our weak cation exchange (WCX) TOF MS method yielded very low inter/intra run coefficients of variation. Surprisingly, however, in samples from kidney disease patients, we detected a novel peak (m/z 2673.9) with low intensity that could be identified as hepcidin-24 and had previously remained unnoticed due to peak interference with the formerly used internal standard. Using a cell-based bioassay it was shown that synthetic hepcidin-24 was, like the -22 and -20 isoforms, a significantly less potent inducer of ferroportin degradation than hepcidin-25. During prolonged storage of plasma at room temperature, we observed that a decrease in plasma hepcidin-25 was paralleled by an increase in the levels of the hepcidin-24, -22 and -20 isoforms. This provides first evidence that all determinants for the conversion of hepcidin-25 to smaller inactive isoforms are present in the circulation, which may contribute to the functional suppression of hepcidin-25, that is significantly elevated in patients with renal impairment. The present update of our hepcidin TOF MS assay together with improved insights in the source and preparation of the internal standard, and sample stability will further improve our understanding of circulating hepcidin and pave the way towards further optimization and standardization of plasma hepcidin assays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hepcidin Regulates Cellular Iron Efflux by Binding to Ferroportin and Inducing Its Internalization
Nemeth, E., Tuttle, M. S., Powelson, J., Vaughn, M. B., Donovan, A., Ward, D. M., Ganz, T., & Kaplan, J. (2004) · Science · doi:10.1126/science.1104742 · Cited by 4,803 · cited 2×
“[32,33] except that fluorescence was quantified in triplicate wells on a microplate reader.”
Hepcidin, a urinary antimicrobial peptide synthesized in the liver
Park, C. H., Valore, E. V., Waring, A. J., & Ganz, T. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.m008922200 · Cited by 2,168 · cited 1×
“Under physiological conditions N2terminal truncated hepcidin220 and 222 peptides have been observed in the urine, but not or at low concentrations, in plasma [2–7].”
Hunter, H. N., Fulton, D. B., Ganz, T., & Vogel, H. J. (2002) · Journal of Biological Chemistry · doi:10.1074/jbc.m205305200 · Cited by 400
Rivera, S., Nemeth, E., Gabayan, V., Lopez, M. A., Farshidi, D., & Ganz, T. (2005) · Blood · doi:10.1182/blood-2005-04-1766 · Cited by 308 · cited 1×
“Notably, the activities of the shorter hepcidin-22 and -20 isoforms were at least 10-fold lower than that of hepcidin224, which is in-line with the previously reported effects of truncation at the amino-terminus [33,34].”
Nemeth, E., Preza, G. C., Jung, C.-L., Kaplan, J., Waring, A. J., & Ganz, T. (2006) · Blood · doi:10.1182/blood-2005-05-2049 · Cited by 273
Hepcidin in Human Iron Disorders: Diagnostic Implications
Kroot, J. J., Tjalsma, H., Fleming, R. E., & Swinkels, D. W. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2009.140053 · Cited by 246 · cited 1×
“The measurement of hepcidin in biological fluids is therefore a promising tool in the diagnosis and management of medical conditions in which iron metabolism is affected [1].”
Self-citationValore, E. V., & Ganz, T. (2008) · Blood Cells Molecules and Diseases · doi:10.1016/j.bcmd.2007.07.009 · Cited by 234 · cited 1×
“and that dipeptidylpeptidase 4 is involved in the processing of hepcidin-22 into hepcidin-20 [11,12].”
Hohlbaum, A. M., Trentman, S., Gille, H., Allersdorfer, A., Belaiba, R. S., Huelsmeyer, M., Christian, J., Sandal, T., Matschiner, G., Jensen, K., et al. (2011) · Blood · doi:10.1182/blood.v118.21.687.687 · Cited by 16
Self-citation
Cited by
Hepcidin in the diagnosis of iron disorders
Girelli, D., Nemeth, E., & Swinkels, D. W. (2016) · Blood · doi:10.1182/blood-2015-12-639112 · Cited by 417
Self-citationNeubert, H., Shuford, C. M., Olah, T. V., Garofolo, F., Schultz, G. A., Jones, B. R., Amaravadi, L., Laterza, O. F., Xu, K., & Ackermann, B. L. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvz022 · Cited by 109
Hepcidin and iron disorders: new biology and clinical approaches
Arezes, J., & Nemeth, E. (2015) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12358 · Cited by 88
“titate total hepcidin, without distinguishing the fulllength hepcidin (hepcidin-25) from smaller isoforms (hepcidin-20, -22, and -24) [24].”
BackgroundBadenhorst, C. E., Dawson, B., Cox, G. R., Laarakkers, C. M., Swinkels, D. W., & Peeling, P. (2015) · European Journal of Applied Physiology · doi:10.1007/s00421-015-3252-3 · Cited by 57
Self-citationUnraveling Hepcidin Plasma Protein Binding: Evidence from Peritoneal Equilibration Testing
Diepeveen, L. E., Laarakkers, C. M., Peters, H. P. E., van Herwaarden, A. E., Groenewoud, H., IntHout, J., Wetzels, J. F., van Swelm, R. P. L., & Swinkels, D. W. (2019) · Pharmaceuticals · doi:10.3390/ph12030123 · Cited by 11
“Measurements of hepcidin were performed by a combination of weak cation exchange chromatography and time-of-flight mass spectrometry (WCX-TOF MS) using a stable hepcidin-25+40 isotope as internal standard for quantification [55].”
MethodSelf-citation
Metadata
- Authors
- Laarakkers, C. M. M., Wiegerinck, E. T., Klaver, S., Kolodziejczyk, M., Gille, H., Hohlbaum, A. M., Tjalsma, H., & Swinkels, D. W.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2013-10-04
- Volume
- 8
- Issue
- 10
- Pages
- e75518
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W1993415721
- Cited by
- 84
- References
- 8
- FWCI
- 6.61
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.