Implementation of Microfluidic Sandwich ELISA for Superior Detection of Plant Pathogens
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Rapid and economical screening of plant pathogens is a high-priority need in the seed industry. Crop quality control and disease surveillance demand early and accurate detection in addition to robustness, scalability, and cost efficiency typically required for selective breeding and certification programs. Compared to conventional bench-top detection techniques routinely employed, a microfluidic-based approach offers unique benefits to address these needs simultaneously. To our knowledge, this work reports the first attempt to perform microfluidic sandwich ELISA for Acidovorax citrulli (Ac), watermelon silver mottle virus (WSMoV), and melon yellow spot virus (MYSV) screening. The immunoassay occurs on the surface of a reaction chamber represented by a microfluidic channel. The capillary force within the microchannel draws a reagent into the reaction chamber as well as facilitates assay incubation. Because the underlying pad automatically absorbs excess fluid, the only operation required is sequential loading of buffers/reagents. Buffer selection, antibody concentrations, and sample loading scheme were optimized for each pathogen. Assay optimization reveals that the 20-folds lower sample volume demanded by the microchannel structure outweighs the 2- to 4-folds higher antibody concentrations required, resulting in overall 5-10 folds of reagent savings. In addition to cutting the assay time by more than 50%, the new platform offers 65% cost savings from less reagent consumption and labor cost. Our study also shows 12.5-, 2-, and 4-fold improvement in assay sensitivity for Ac, WSMoV, and MYSV, respectively. Practical feasibility is demonstrated using 19 real plant samples. Given a standard 96-well plate format, the developed assay is compatible with commercial fluorescent plate readers and readily amendable to robotic liquid handling systems for completely hand-free assay automation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“While intravital imaging has proven extremely useful in the study of metastasis[6–7], it requires specialized expertise and equipment, and high image resolution is harder to attain in some visceral organs due to the depth of their location.”
From Microfluidics: A New Tool for Modeling Cancer–Immune Interactions (2016) · cites this paper as [7]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379 · cited 1×
“Microfluidic systems or micro total analysis systems (mTAS) offer several desirable advantages such as greater sensitivity, faster turnaround time, and lower sample consumption, owing to unique properties of miniaturization such as small volume, large surfaceto-volume ratio, short diffusion distance, laminar flow, and…”
BackgroundPlant Disease: A Threat to Global Food Security
Strange, R. N., & Scott, P. R. (2005) · Annual Review of Phytopathology · doi:10.1146/annurev.phyto.43.113004.133839 · Cited by 1,802 · cited 1×
“Faced with increasing demand, the industry is in need of rapid and reliable methods to screen seedborne pathogens that, if present, can pose serious threats to not only the business worldwide but also the global food supply [3].”
BackgroundPhysics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800 · cited 1×
“Microfluidic systems or micro total analysis systems (mTAS) offer several desirable advantages such as greater sensitivity, faster turnaround time, and lower sample consumption, owing to unique properties of miniaturization such as small volume, large surfaceto-volume ratio, short diffusion distance, laminar flow, and…”
BackgroundAlternaria spp.: from general saprophyte to specific parasite
Thomma, B. P. H. J. (2003) · Molecular Plant Pathology · doi:10.1046/j.1364-3703.2003.00173.x · Cited by 807 · cited 1×
“These pathogens ranging from bacteria [5], viruses [6,7], fungi [8], and parasites [9] reduce both quality and quantity of agricultural products as well as result in trade bans on exporters.”
BackgroundMolecular biology of the Bunyaviridae
Elliott, R. M. (1990) · Journal of General Virology · doi:10.1099/0022-1317-71-3-501 · Cited by 444 · cited 1×
“Given that WSMoV and MYSV are members of the Bunyaviridae family, which generally has 2,100 copies of NP per viral particle [36] with each NP weighing ,31 kDa [37], assay sensitivity can also be calculated in terms of viral particle copy numbers.”
BackgroundMicrofluidics: Applications for analytical purposes in chemistry and biochemistry
Ohno, K., Tachikawa, K., & Manz, A. (2008) · ELECTROPHORESIS · doi:10.1002/elps.200800121 · Cited by 398 · cited 1×
“Though staggering progress in miniaturization technology has been made in the field of biotechnology during the past decades [20,21], applications of microfluidic systems in agricultural applications are still very limited.”
BackgroundInnovative tools for detection of plant pathogenic viruses and bacteria
López, M. M., Bertolini, E., Olmos, A., Caruso, P., Gorris, M. T., Llop, P., Penyalver, R., & Cambra, M. (2003) · International Microbiology · doi:10.1007/s10123-003-0143-y · Cited by 315 · cited 2×
“Newer technique such as loop-mediated isothermal amplification [12,13] though can suffer from similar drawbacks, has started to gain interest due to its frequently improved assay performance and simpler instrumentation over traditional PCR.”
MethodMass transport and surface reactions in microfluidic systems
Gervais, T., & Jensen, K. F. (2006) · Chemical Engineering Science · doi:10.1016/j.ces.2005.06.024 · Cited by 301 · cited 1×
“Due to the ‘‘fully developed region’’ operation regime of pressure-driven flow that is a unique characteristic of a microchannel structure [35], higher portion of bound molecules can be achieved in this format than those in its traditional 96-well counterpart.”
BackgroundThe Epidemiology and Management of Seedborne Bacterial Diseases
Gitaitis, R., & Walcott, R. (2007) · Annual Review of Phytopathology · doi:10.1146/annurev.phyto.45.062806.094321 · Cited by 178 · cited 1×
“These pathogens ranging from bacteria [5], viruses [6,7], fungi [8], and parasites [9] reduce both quality and quantity of agricultural products as well as result in trade bans on exporters.”
BackgroundIsothermal DNA Amplification in Bioanalysis: Strategies and Applications
Kim, J., & Easley, C. J. (2011) · Bioanalysis · doi:10.4155/bio.10.172 · Cited by 168 · cited 1×
“Newer technique such as loop-mediated isothermal amplification [12,13] though can suffer from similar drawbacks, has started to gain interest due to its frequently improved assay performance and simpler instrumentation over traditional PCR.”
Method
Cited by
Microfluidics: A New Tool for Modeling Cancer–Immune Interactions
Boussommier-Calleja, A., Li, R., Chen, M. B., Wong, S. C., & Kamm, R. D. (2016) · Trends in Cancer · doi:10.1016/j.trecan.2015.12.003 · Cited by 224
“Of note, microfluidic platforms that include such miniaturized assays on-chip are currently being developed[7, 8].”
BackgroundRecent progress of microfluidic reactors for biomedical applications
Shi, H., Nie, K., Dong, B., Long, M., Xu, H., & Liu, Z. (2019) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.12.104 · Cited by 204
Zhong, M., Yang, L., Yang, H., Cheng, C., Deng, W., Tan, Y., Xie, Q., & Yao, S. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.11.001 · Cited by 189
Internet of Things‐Enabled Food and Plant Sensors to Empower Sustainability
Kachouei, M. A., Kaushik, A. K., & Ali, M. A. (2023) · Advanced Intelligent Systems · doi:10.1002/aisy.202300321 · Cited by 149
Rapid Detection of Food Allergens by Microfluidics ELISA-Based Optical Sensor
Weng, X., Gaur, G., & Neethirajan, S. R. (2016) · Biosensors · doi:10.3390/bios6020024 · Cited by 117
“Microfluidics has become an increasingly popular and powerful tool in biochemistry applications [18] and presents distinctive advantages, such as faster reaction times, lower sample consumption, greater sensitivity, small dimensions, short diffusion distance, and high surface tension [19,20].”
Background
Metadata
- Authors
- Thaitrong, N., Charlermroj, R., Himananto, O., Seepiban, C., & Karoonuthaisiri, N.
- Affiliations
- National Science and Technology Development Agency (TH)
- Corresponding author
- Thaitrong, Numrin
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2013-12-23
- Volume
- 8
- Issue
- 12
- Pages
- e83231
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC3871650
- OpenAlex
- W2015115692
- Cited by
- 34
- References
- 35
- Citations by year
- 2026: 1 · 2025: 5 · 2024: 2 · 2023: 4 · 2022: 1 · 2020: 1 · 2019: 3 · 2018: 4 · 2017: 3 · 2016: 4 · 2015: 2 · 2014: 3
- FWCI
- 1.66
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Greater South Information System
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Life Sciences › Agricultural and Biological Sciences › Plant Science › Plant Virus Research Studies
- Keywords
- plant pathogen detection, Acidovorax citrulli, Watermelon silver mottle virus, seed certification, reagent cost reduction, assay sensitivity, robotic liquid handling
- MeSH terms
- Animals, Antibodies, Bacterial, Antibodies, Viral, Enzyme-Linked Immunosorbent Assay, Plant Diseases, Plants, Rabbits, Robotics, Sensitivity and Specificity, Time Factors, Tospovirus, Comamonadaceae, Microfluidic Analytical Techniques, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implementation of Microfluidic Sandwich ELISA for Superior Detection of Plant Pathogens. https://app.cochat.ai/papers/10.1371/journal.pone.0083231
- The paper
- Thaitrong, N., Charlermroj, R., Himananto, O., Seepiban, C., & Karoonuthaisiri, N. (2013). Implementation of Microfluidic Sandwich ELISA for Superior Detection of Plant Pathogens. PLoS ONE. https://doi.org/10.1371/journal.pone.0083231
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.