Variability of CSF Alzheimer’s Disease Biomarkers: Implications for Clinical Practice
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Cerebrospinal fluid (CSF) biomarkers are increasingly being used for diagnosis of Alzheimer's disease (AD). OBJECTIVE: We investigated the influence of CSF intralaboratory and interlaboratory variability on diagnostic CSF-based AD classification of subjects and identified causes of this variation. METHODS: We measured CSF amyloid-β (Aβ) 1-42, total tau (t-tau), and phosphorylated tau (p-tau) by INNOTEST enzyme-linked-immunosorbent assays (ELISA) in a memory clinic population (n = 126). Samples were measured twice in a single or two laboratories that served as reference labs for CSF analyses in the Netherlands. Predefined cut-offs were used to classify CSF biomarkers as normal or abnormal/AD pattern. RESULTS: CSF intralaboratory variability was higher for Aβ1-42 than for t-tau and p-tau. Reanalysis led to a change in biomarker classification (normal vs. abnormal) of 26% of the subjects based on Aβ1-42, 10% based on t-tau, and 29% based on p-tau. The changes in absolute biomarker concentrations were paralleled by a similar change in levels of internal control samples between different assay lots. CSF interlaboratory variability was higher for p-tau than for Aβ1-42 and t-tau, and reanalysis led to a change in biomarker classification of 12% of the subjects based on Aβ1-42, 1% based on t-tau, and 22% based on p-tau. CONCLUSIONS: Intralaboratory and interlaboratory CSF variability frequently led to change in diagnostic CSF-based AD classification for Aβ1-42 and p-tau. Lot-to-lot variation was a major cause of intralaboratory variability. This will have implications for the use of these biomarkers in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Jack, C. R., Albert, M. S., Knopman, D. S., McKhann, G. M., Sperling, R. A., Carrillo, M. C., Thies, B., & Phelps, C. H. (2011) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2011.03.004 · Cited by 2,042 · cited 1×
“For the moment this rightly restricts the indication for CSF biomarker testing in diagnostic guidelines as complimentary and non-obligatory [19,20].”
BackgroundCSF markers for incipient Alzheimer's disease
Blennow, K., & Hampel, H. (2003) · The Lancet Neurology · doi:10.1016/s1474-4422(03)00530-1 · Cited by 1,291 · cited 1×
“Amyloid-b (Ab) 1-42, total tau (t-tau), and phosphorylated tau (p-tau) proteins in cerebrospinal fluid (CSF) are well-established biomarkers for Alzheimer’s disease (AD) [1–3], and are increasingly being used for diagnosis in clinical practice.”
BackgroundEFNS guidelines for the diagnosis and management of Alzheimer's disease
Hort, J., O’Brien, J. T., Gainotti, G., Pirttila, T., Popescu, B. O., Rektorova, I., Sorbi, S., Scheltens, P., & Dementia, O. B. O. T. E. S. P. O. (2010) · European Journal of Neurology · doi:10.1111/j.1468-1331.2010.03040.x · Cited by 490
Self-citationVanderstichele, H., Bibl, M., Engelborghs, S., Le Bastard, N., Lewczuk, P., Molinuevo, J. L., Parnetti, L., Perret‐Liaudet, A., Shaw, L. M., Teunissen, C., et al. (2012) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2011.07.004 · Cited by 358 · cited 2×
“The recent consensus on standardization of preanalytical aspects of CSF analyses [15,17], as well as the ongoing worldwide quality control study [6], and standardization projects (www.”
BackgroundSelf-citationdel Campo, M., Mollenhauer, B., Bertolotto, A., Engelborghs, S., Hampel, H., Simonsen, A. H., Kapaki, E., Kruse, N., Le Bastard, N., Lehmann, S., et al. (2012) · Biomarkers in Medicine · doi:10.2217/bmm.12.46 · Cited by 343 · cited 2×
“The recent consensus on standardization of preanalytical aspects of CSF analyses [15,17], as well as the ongoing worldwide quality control study [6], and standardization projects (www.”
BackgroundSelf-citation
Cited by
Hansson, O., Seibyl, J., Stomrud, E., Zetterberg, H., Trojanowski, J. Q., Bittner, T., Lifke, V., Corradini, V., Eichenlaub, U., Batrla, R., et al. (2018) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2018.01.010 · Cited by 808
“Unfortunately, the currently available CSF assays for Ab(1–42), pTau, and tTau are limited by considerable variability between laboratories and assay batches [20,21].”
BackgroundPalmqvist, S., Janelidze, S., Stomrud, E., Zetterberg, H., Karl, J., Zink, K., Bittner, T., Mattsson, N., Eichenlaub, U., Blennow, K., et al. (2019) · JAMA Neurology · doi:10.1001/jamaneurol.2019.1632 · Cited by 435
Bittner, T., Zetterberg, H., Teunissen, C. E., Ostlund, R. E., Militello, M., Andreasson, U., Hubeek, I., Gibson, D., Chu, D. C., Eichenlaub, U., et al. (2016) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2015.09.009 · Cited by 374
“These issues include high lot-to-lot variability for enzyme-linked immunosorbent assays (ELISAs) [12], as well as between-laboratory variability associated with differences in laboratory procedures and analytical techniques, as assays are most often run manually [13].”
Prevalence Estimates of Amyloid Abnormality Across the Alzheimer Disease Clinical Spectrum
Jansen, W. J., Janssen, O., Tijms, B. M., Vos, S. J. B., Ossenkoppele, R., Visser, P. J., Amyloid Biomarker Study Group, Aarsland, D., Alcolea, D., Altomare, D., et al. (2022) · JAMA Neurology · doi:10.1001/jamaneurol.2021.5216 · Cited by 290
Self-citationCerebrospinal fluid biomarkers measured by Elecsys assays compared to amyloid imaging
Schindler, S. E., Gray, J. D., Gordon, B. A., Xiong, C., Batrla‐Utermann, R., Quan, M., Wahl, S., Benzinger, T. L. S., Holtzman, D. M., Morris, J. C., et al. (2018) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2018.01.013 · Cited by 284
Metadata
- Authors
- Vos, S. J. B., Visser, P. J., Verhey, F., Aalten, P., Knol, D., Ramakers, I., Scheltens, P., Rikkert, M. G. M. O., Verbeek, M. M., & Teunissen, C. E.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2014-06-24
- Volume
- 9
- Issue
- 6
- Pages
- e100784
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2075606978
- Cited by
- 93
- References
- 6
- FWCI
- 7.41
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.