Abstract

BACKGROUND: Since a previous meta-analysis reported that ultrasound guidance was associated with a higher first-attempt success rate in catheterization of the radial artery, a number of randomized controlled trials (RCTs) have reported inconsistent results. The aim of the present study is to conduct an updated meta-analysis to clarify the role of ultrasound guidance for radial artery catheterization. METHODS: A systematic literature search of PubMed, Embase, and Cochrane Central Register of Controlled Trials was conducted using specific search terms. Eligible studies were RCTs that compared ultrasound guidance with traditional palpation for radial artery catheterization. The Mantel-Haenszel method using the random effects model was adopted in this meta-analysis. RESULTS: Seven RCTs with 482 patients were included. Compared with traditional palpation, ultrasound guidance significantly increased the first-attempt success rate of radial artery catheterization (RR 1.51, 95% CI 1.07-2.14, P = 0.02). Subgroup analyses suggested that the superiority of ultrasound guidance for radial artery catheterization was significant when the technique was operated by experienced users, performed in small children and infants, and on elective procedures in the operating room. In addition, ultrasound guidance significantly reduced mean-attempts to success (WMD -1.13, 95% CI -1.58 to -0.69, P<0.00001), mean-time to success (WMD -74.77s, 95% CI -137.89s to -11.64s, P = 0.02), and the occurrence of hematoma (RR 0.17, 95% CI 0.07-0.41, P = 0.0001). CONCLUSIONS: The present meta-analysis suggests a clear benefit from ultrasound guidance for radial artery catheterization compared with the traditional palpation. Preliminary training and familiarization with the ultrasound-guided technique is needed before applying it for radial artery catheterization, especially for inexperienced operators.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0111527

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 93

Metadata

Authors
Tang, L., Wang, F., Li, Y., Zhao, L., Xi, H., Guo, Z., Li, X., Gao, C., Wang, J., & Zhou, L.
Venue
PLoS ONE
Published
2014-11-06
Volume
9
Issue
11
Pages
e111527
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2065104258
Cited by
93
References
2
FWCI
1.27
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrasound Guidance for Radial Artery Catheterization: An Updated Meta-Analysis of Randomized Controlled Trials. https://app.cochat.ai/papers/10.1371/journal.pone.0111527
The paper
Tang, L., Wang, F., Li, Y., Zhao, L., Xi, H., Guo, Z., Li, X., Gao, C., Wang, J., & Zhou, L. (2014). Ultrasound Guidance for Radial Artery Catheterization: An Updated Meta-Analysis of Randomized Controlled Trials. PLoS ONE. https://doi.org/10.1371/journal.pone.0111527

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.