CoChat

Competition between Serum IgG, IgM, and IgA Anti-Glycan Antibodies

Open access

The DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.

Abstract

Anti-glycan antibodies are an abundant subpopulation of serum antibodies with critical functions in many immune processes. Changes in the levels of these antibodies can occur with the onset of disease, exposure to pathogens, or vaccination. As a result, there has been significant interest in exploiting anti-glycan antibodies as biomarkers for many diseases. Serum contains a mixture of anti-glycan antibodies that can recognize the same antigen, and competition for binding can potentially influence the detection of antibody subpopulations that are more relevant to disease processes. The most abundant antibody isotypes in serum are IgG, IgM, and IgA, but little is known regarding how these different isotypes compete for the same glycan antigen. In this study, we developed a multiplexed glycan microarray assay and applied it to evaluate how different isotypes of anti-glycan antibodies (IgA, IgG, and IgM) compete for printed glycan antigens. While IgG and IgA antibodies typically outcompete IgM for peptide or protein antigens, we found that IgM outcompete IgG and IgA for many glycan antigens. To illustrate the importance of this effect, we provide evidence that IgM competition can account for the unexpected observation that IgG of certain antigen specificities appear to be preferentially transported from mothers to fetuses. We demonstrate that IgM in maternal sera compete with IgG resulting in lower than expected IgG signals. Since cord blood contains very low levels of IgM, competition only affects maternal IgG signals, making it appear as though certain IgG antibodies are higher in cord blood than matched maternal blood. Taken together, the results highlight the importance of competition for studies involving anti-glycan antibodies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0119298

Cites

81 of 81 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig 1 Competition between serum IgG, IgA, and IgM anti-glycan antibodies. (A) Addition of IgM and IgA to IgG. Polyclonal IgG isolated from serum was first profiled on the array alone. Separately, IgG was premixed with varying amounts of IgM or IgA and then profiled on the array. For each array component, the change in IgG signal in the presence of IgM or IgA was determined. The box plots depict the range of IgG changes (on a log base 2 scale) measured on the array upon addition of 4 serum equivalents of IgM or IgA. The line in the middle of the box is the median, the box spans 1 standard deviation above and below the median, and the whiskers represent 2 standard deviations above or below the median. (B) Addition of IgG and IgA to IgM. An analogous protocol as above was used to evaluate effects of IgG and IgA on IgM signals. (C) Addition of IgM and IgG to IgA. An analogous protocol as above was used to evaluate effects of IgG and IgM on IgA signals. The box plots demonstrate significant decreases in IgG and IgA signals in the presence of IgM for the vast majority of array components.
Fig 1 Competition between serum IgG, IgA, and IgM anti-glycan antibodies. (A) Addition of IgM and IgA to IgG. Polyclonal IgG isolated from serum was first profiled on the array alone. Separately, IgG was premixed with varying amounts of IgM or IgA and then profiled on the array. For each array component, the change in IgG signal in the presence of IgM or IgA was determined. The box plots depict the range of IgG changes (on a log base 2 scale) measured on the array upon addition of 4 serum equivalents of IgM or IgA. The line in the middle of the box is the median, the box spans 1 standard deviation above and below the median, and the whiskers represent 2 standard deviations above or below the median. (B) Addition of IgG and IgA to IgM. An analogous protocol as above was used to evaluate effects of IgG and IgA on IgM signals. (C) Addition of IgM and IgG to IgA. An analogous protocol as above was used to evaluate effects of IgG and IgM on IgA signals. The box plots demonstrate significant decreases in IgG and IgA signals in the presence of IgM for the vast majority of array components.CC0 · PubMed Central
Fig 2 Dose-dependent inhibition of IgG and IgA signals upon addition of IgM. (A) Decrease in IgG signals with increase in IgM concentration. (B) Decrease in IgA signals with increase in IgM concentration. Polyclonal IgG and IgA isolated from serum were first profiled on the array alone. Separately, they were pre-mixed with varying amounts of IgM and then profiled on the array. The box plots depict the range of IgG or IgA signals (on a log base 2 scale) alone or in the presence of varying amounts of IgM (50–400 μg/mL). The line in the middle of the box is the median signal, the box spans 1 standard deviation above and below the median, and the whiskers represent 2 standard deviations above or below the median. The box plots demonstrate decreasing IgG and IgA signals in the presence of increasing amounts of IgM across the entire array.
Fig 2 Dose-dependent inhibition of IgG and IgA signals upon addition of IgM. (A) Decrease in IgG signals with increase in IgM concentration. (B) Decrease in IgA signals with increase in IgM concentration. Polyclonal IgG and IgA isolated from serum were first profiled on the array alone. Separately, they were pre-mixed with varying amounts of IgM and then profiled on the array. The box plots depict the range of IgG or IgA signals (on a log base 2 scale) alone or in the presence of varying amounts of IgM (50–400 μg/mL). The line in the middle of the box is the median signal, the box spans 1 standard deviation above and below the median, and the whiskers represent 2 standard deviations above or below the median. The box plots demonstrate decreasing IgG and IgA signals in the presence of increasing amounts of IgM across the entire array.CC0 · PubMed Central
Fig 3 Dependence of inhibition on carbohydrate antigen structure. Measured IgG signals to Forssman disaccharide and tetrasaccharide (A) and four blood group A antigens (B) in the absence of added IgM (0 μg/mL) or in the presence of varying amounts of IgM (50–400 μg/mL).
Fig 3 Dependence of inhibition on carbohydrate antigen structure. Measured IgG signals to Forssman disaccharide and tetrasaccharide (A) and four blood group A antigens (B) in the absence of added IgM (0 μg/mL) or in the presence of varying amounts of IgM (50–400 μg/mL).CC0 · PubMed Central
Fig 4 Changes in serum IgG and IgM signals in a pooled serum sample in the presence of varying amounts of added IgG, IgA, or IgM. (A) Changes in IgG signals upon addition of IgM. (B) Changes in IgG signals upon addition of IgA. (C) Changes in IgM signals upon addition of IgG. (D) Changes in IgM signals upon addition of IgA. IgG and IgM signals in a pooled serum sample were first profiled on the array alone. Separately, the serum sample was pre-mixed with varying amounts of IgG, IgA, or IgM and then profiled on the array. The box plots depict the range of IgG or IgM signals (on a log base 2 scale) alone or in the presence of varying amounts of IgG, IgA, or IgM. The line in the middle of the box is the median signal, the box spans 1 standard deviation above and below the median, and the whiskers represent 2 standard deviations above or below the median. The only significant decreases observed are for IgG signals upon addition of IgM.
Fig 4 Changes in serum IgG and IgM signals in a pooled serum sample in the presence of varying amounts of added IgG, IgA, or IgM. (A) Changes in IgG signals upon addition of IgM. (B) Changes in IgG signals upon addition of IgA. (C) Changes in IgM signals upon addition of IgG. (D) Changes in IgM signals upon addition of IgA. IgG and IgM signals in a pooled serum sample were first profiled on the array alone. Separately, the serum sample was pre-mixed with varying amounts of IgG, IgA, or IgM and then profiled on the array. The box plots depict the range of IgG or IgM signals (on a log base 2 scale) alone or in the presence of varying amounts of IgG, IgA, or IgM. The line in the middle of the box is the median signal, the box spans 1 standard deviation above and below the median, and the whiskers represent 2 standard deviations above or below the median. The only significant decreases observed are for IgG signals upon addition of IgM.CC0 · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 81 references

Research works printed but not linked: 1

  1. Campbell CT, Zhang Y, Gildersleeve JC (2010) Construction and use of glycan microarrays. Current Protocols in Chemical Biology 2: 37– 53. 10.1002/9780470559277.ch090228 23836542 PMC4533865 · DOI

Cited by

See all 53

Metadata

Authors
Muthana, S. M., Xia, L., Campbell, C. T., Zhang, Y., & Gildersleeve, J. C.
Affiliations
National Institutes of Health (US)
Corresponding author
Gildersleeve, Jeffrey C.
Venue
PLOS ONE
Published
2015-03-25
Volume
10
Issue
3
Pages
e0119298
ISSN
1932-6203 (ISSN-L)
OpenAlex
W1977905136
Cited by
53
References
81
Citations by year
2026: 6 · 2025: 5 · 2024: 7 · 2023: 2 · 2022: 6 · 2021: 6 · 2020: 4 · 2019: 4 · 2018: 1 · 2017: 4 · 2016: 6 · 2015: 2
FWCI
1.88
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, public-domain)
  • PubMed Central (publishedVersion, public-domain)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Figshare (submittedVersion, cc-by)
Funders
  • Michigan State University
  • National Institutes of Health (GM62116)
  • College of Engineering, Michigan State University
  • National Cancer Institute (GM62116)
  • National Institute of General Medical Sciences (GM 62116, U54GM062116)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Glycosylation and Glycoproteins Research
  • Life Sciences › Immunology and Microbiology › Immunology › Monoclonal and Polyclonal Antibodies Research
  • Physical Sciences › Chemistry › Organic Chemistry › Carbohydrate Chemistry and Synthesis
Keywords
anti-glycan antibodies, IgG, IgM, IgA, glycan microarrays, maternal-fetal antibody transfer, umbilical cord blood, biomarkers
MeSH terms
Antibody Affinity, Antigen-Antibody Reactions, Humans, Immunoglobulin A, Immunoglobulin G, Immunoglobulin M, Polysaccharides, Biomarkers, Protein Array Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Competition between Serum IgG, IgM, and IgA Anti-Glycan Antibodies. https://app.cochat.ai/papers/10.1371/journal.pone.0119298
The paper
Muthana, S. M., Xia, L., Campbell, C. T., Zhang, Y., & Gildersleeve, J. C. (2015). Competition between Serum IgG, IgM, and IgA Anti-Glycan Antibodies. PLOS ONE. https://doi.org/10.1371/journal.pone.0119298

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.