Wearable Sensor Use for Assessing Standing Balance and Walking Stability in People with Parkinson’s Disease: A Systematic Review
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Postural instability and gait disability threaten the independence and well-being of people with Parkinson's disease and increase the risk of falls and fall-related injuries. Prospective research has shown that commonly-used clinical assessments of balance and walking lack the sensitivity to accurately and consistently identify those people with Parkinson's disease who are at a higher risk of falling. Wearable sensors provide a portable and affordable alternative for researchers and clinicians who are seeking to objectively assess movements and falls risk in the clinical setting. However, no consensus currently exists on the optimal placements for sensors and the best outcome measures to use for assessing standing balance and walking stability in Parkinson's disease patients. Hence, this systematic review aimed to examine the available literature to establish the best sensor types, locations and outcomes to assess standing balance and walking stability in this population. METHODS: Papers listed in three electronic databases were searched by title and abstract to identify articles measuring standing balance or walking stability with any kind of wearable sensor among adults diagnosed with PD. To be eligible for inclusion, papers were required to be full-text articles published in English between January 1994 and December 2014 that assessed measures of standing balance or walking stability with wearable sensors in people with PD. Articles were excluded if they; i) did not use any form of wearable sensor to measure variables associated with standing balance or walking stability; ii) did not include a control group or control condition; iii) were an abstract and/or included in the proceedings of a conference; or iv) were a review article or case study. The targeted search of the three electronic databases identified 340 articles that were potentially eligible for inclusion, but following title, abstract and full-text review only 26 articles were deemed to meet the inclusion criteria. Included articles were assessed for methodological quality and relevant data from the papers were extracted and synthesized. RESULTS: Quality assessment of these included articles indicated that 31% were of low methodological quality, while 58% were of moderate methodological quality and 11% were of high methodological quality. All studies adopted a cross-sectional design and used a variety of sensor types and outcome measures to assess standing balance or walking stability in people with Parkinson's disease. Despite the typically low to moderate methodological quality, 81% of the studies reported differences in sensor-based measures of standing balance or walking stability between different groups of Parkinson's disease patients and/or healthy controls. CONCLUSION: These data support the use of wearable sensors for detecting differences in standing balance and walking stability between people with PD and controls. Further high-quality research is needed to better understand the utility of wearable sensors for the early identification of Parkinson's disease symptoms and for assessing falls risk in this population. PROSPERO REGISTRATION: CRD42014010838.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Downs, S. H., & Black, N. (1998) · Journal of Epidemiology and Community Health · doi:10.1136/jech.52.6.377 · Cited by 8,252
Steffen, T. M., Hacker, T. A., & Mollinger, L. (2002) · Physical Therapy · doi:10.1093/ptj/82.2.128 · Cited by 2,070
ISway: a sensitive, valid and reliable measure of postural control
Mancini, M., Salarian, A., Carlson-Kuhta, P., Zampieri, C., King, L., Chiari, L., & Horak, F. B. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-59 · Cited by 499 · cited 9×
“the Romberg test, tandem stance, semi-tandem stance, standing with eyes open and eyes closed) [13, 25, 26, 32, 33, 38, 40].”
BackgroundMethodInfluentialiTUG, a Sensitive and Reliable Measure of Mobility
Salarian, A., Horak, F. B., Zampieri, C., Carlson-Kuhta, P., Nutt, J. G., & Aminian, K. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047606 · Cited by 489
Postural sway as a marker of progression in Parkinson's disease: A pilot longitudinal study
Mancini, M., Carlson-Kuhta, P., Zampieri, C., Nutt, J. G., Chiari, L., & Horak, F. B. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.04.010 · Cited by 221 · cited 9×
“Sway velocity was another common measure used to evaluate standing balance, but similarly only three studies [25, 26, 33] reported differences between people with PD and controls, while the remaining three did not [13, 32, 38].”
BackgroundMethodResultInfluentialWeiss, A., Herman, T., Plotnik, M., Brozgol, M., Maidan, I., Giladi, N., Gurevich, T., & Hausdorff, J. M. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.10.015 · Cited by 207
Cited by
Technology in Parkinson’s disease: challenges and opportunities
Espay, A. J., Bonato, P., Nahab, F. B., Maetzler, W., Dean, J. M., Klucken, J., Eskofier, B. M., Merola, A., Horak, F., Lang, A. E., et al. (2016) · Movement Disorders · doi:10.1002/mds.26642 · Cited by 654
Del Din, S., Godfrey, A., Galna, B., Lord, S., & Rochester, L. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0154-5 · Cited by 349
New methods for the assessment of Parkinson's disease (2005 to 2015): A systematic review
Sánchez‐Ferro, Á., Elshehabi, M., Godinho, C., Salkovic, D., Hobert, M. A., Domingos, J., van Uem, J. M., Ferreira, J. J., & Maetzler, W. (2016) · Movement Disorders · doi:10.1002/mds.26723 · Cited by 145
“In addition to a narrative(2) and a systematic review(9) by some of the authors listed here, a systematic review on wearable technology for the assessment of gait and balance has recently been published.(7) None of these reviews provide an exhaustive and comprehensive overview of the current state of the NAM-PD field…”
BackgroundRabelo, A. G., Neves, L. P., Paixão, A. P. S., Oliveira, F. H. M., de Souza, L. A. P. S., Vieira, M. F., Pereira, A. A., & Andrade, A. O. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-017-1908-3 · Cited by 46
Comparing laboratory and in-the-wild data for continuous Parkinson’s Disease tremor detection
Zhang, A., De la Torre, F., & Hodgins, J. (2020) · 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176255 · Cited by 12
Metadata
- Authors
- Hubble, R. P., Naughton, G. A., Silburn, P. A., & Cole, M. H.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2015-04-20
- Volume
- 10
- Issue
- 4
- Pages
- e0123705
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2013773236
- Cited by
- 209
- References
- 6
- FWCI
- 5.02
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.