Plasma Free Hemoglobin Is an Independent Predictor of Mortality among Patients on Extracorporeal Membrane Oxygenation Support
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Hemolysis is common in all extracorporeal circuits as evident by the elevated plasma free hemoglobin (PFHb) level. We investigated whether increased hemolysis during extracorporeal membrane oxygenation (ECMO) is an independent mortality predictor. METHODS: We performed a retrospective observational study of consecutive subjects who received ECMO at a tertiary care facility from 2007-2013 to investigate independent predictors of in-hospital mortality. We examined variables related to patient demographics, comorbidities, markers of hemolysis, ECMO characteristics, transfusion requirements, and complications. 24-hour PFHb > 50 mg/dL was used as a marker of severe hemolysis. RESULTS: 154 patients received ECMO for cardiac (n = 115) or pulmonary (n = 39) indications. Patients' mean age was 51 years and 75.3% were males. Compared to nonsurvivors, survivors had lower pre-ECMO lactic acid (p = 0.026), lower 24-hour lactic acid (p = 0.023), shorter ECMO duration (P = 0.01), fewer RBC transfusions on ECMO (p = 0.008) and lower level of PFHb 24-hours post ECMO implantation (p = 0.029). 24-hour PFHb > 50 mg/dL occurred in 3.9 % versus 15.5% of survivors and nonsurvivors, respectively, p = 0.002. A Cox proportional hazard analysis identified PFHb > 50 mg/dL 24-hours post ECMO as an independent predictor of mortality (OR= 3.4, 95% confidence interval: 1.3 - 8.8, p = 0.011). CONCLUSION: PFHb > 50 mg/dL checked 24-hour post ECMO implantation is a useful tool to predict mortality. We propose the routine checking of PFHb 24-hours after ECMO initiation for early identification and treatment of the cause of hemolysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peek, G. J., Mugford, M., Tiruvoipati, R., Wilson, A., Allen, E., Thalanany, M. M., Hibbert, C. L., Truesdale, A., Clemens, F., Cooper, N., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)61069-2 · Cited by 3,395 · cited 1×
“Extracorporeal membrane oxygenation (ECMO) has shown promising results for critically ill patients, requiring cardiopulmonary support, who are otherwise expected to die [1,2].”
BackgroundRother, R. P., Bell, L., Hillmen, P., & Gladwin, M. T. (2005) · JAMA · doi:10.1001/jama.293.13.1653 · Cited by 1,557 · cited 2×
“There are also concerns of a possible association between high PFHb level and multiple organ failure [14,15].”
BackgroundRastan, A. J., Dege, A., Mohr, M., Doll, N., Falk, V., Walther, T., & Mohr, F. W. (2010) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2009.10.043 · Cited by 609 · cited 1×
“Patients receiving ECMO support experience an approximate 60–75% in-hospital mortality rate [3–6] due to severity of the underlying pathology and high incidence of multiple organ failure, despite improvement in intensive care management and advances in ECMO hardware technology.”
BackgroundChen, Y.-S., Chao, A., Yu, H.-Y., Ko, W.-J., Wu, I.-H., Chen, R. J.-C., Huang, S.-C., Lin, F.-Y., & Wang, S.-S. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02716-x · Cited by 367 · cited 1×
“Successful weaning from ECMO was defined as survival for> 48 hours after ECMO removal [18].”
MethodAubron, C., Cheng, A. C., Pilcher, D., Leong, T., Magrin, G., Cooper, D. J., Scheinkestel, C., & Pellegrino, V. (2013) · Critical Care · doi:10.1186/cc12681 · Cited by 345 · cited 1×
“g severity of main underlying pathology, number of affected organs), it is also affected by ECMOrelated complications such as hemorrhagic events [7], the need for renal replacement therapy [8] during ECMO support, venoarterial ECMOmode [9] and the amount of blood transfused during ECMO support [9].”
BackgroundExtracorporeal Life Support Registry Report 2004
Conrad, S. A., Rycus, P. T., & Dalton, H. (2005) · ASAIO Journal · doi:10.1097/01.mat.0000151922.67540.e9 · Cited by 316
Vercaemst, L. (2008) · The Journal of ExtraCorporeal Technology · doi:10.1051/ject/200840257 · Cited by 269 · cited 2×
“Sublethal RBC damage leading to decreased deformability and increased aggregability will lead to its removal by the spleen, lower oxygen content and decrease ability to enter small capillaries thereby interfering with tissue oxygenation [25] and leading to end organ dysfunction [20].”
BackgroundRenal function and survival in 200 patients undergoing ECMO therapy
Kielstein, J. T., Heiden, A. M., Beutel, G., Gottlieb, J., Wiesner, O., Hafer, C., Hadem, J., Reising, A., Haverich, A., Kühn, C., et al. (2013) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfs398 · Cited by 175 · cited 1×
“g severity of main underlying pathology, number of affected organs), it is also affected by ECMOrelated complications such as hemorrhagic events [7], the need for renal replacement therapy [8] during ECMO support, venoarterial ECMOmode [9] and the amount of blood transfused during ECMO support [9].”
BackgroundSmith, A. H., Hardison, D. C., Bridges, B. B., & Pietsch, J. B. (2012) · Perfusion · doi:10.1177/0267659112457969 · Cited by 136
Cardiovascular surgery and organ damage: Time to reconsider the role of hemolysis
Windsant, I. C. V., Hanssen, S. J., Buurman, W. A., & Jacobs, M. J. H. M. (2011) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2011.02.012 · Cited by 128 · cited 1×
“There are also concerns of a possible association between high PFHb level and multiple organ failure [14,15].”
BackgroundHemolytic characteristics of three commercially available centrifugal blood pumps
Lawson, D. S., Ing, R. J., Cheifetz, I. M., Walczak, R., Craig, D. M., Schulman, S. R., Kern, F. H., Shearer, I. R., Lodge, A. W., & Jaggers, J. J. (2005) · Pediatric Critical Care Medicine · doi:10.1097/01.pcc.0000163282.63992.13 · Cited by 109 · cited 1×
“Lawson and colleagues compared three CF pumps with a roller pump in the incidence of hemolysis by measuring the PFHb and found that 2 centrifugal pumps (the Cobe Revolution and the Jostra Rotaflow) compared favorably with the Cobe Century roller occlusion blood pump regarding the amount of hemolysis produced [28].”
MethodComputation of plasma hemoglobin nitric oxide scavenging in hemolytic anemias
Jeffers, A. B., Gladwin, M. T., & Kim‐Shapiro, D. B. (2006) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2006.08.017 · Cited by 100
Significance of hemolysis on extracorporeal life support after cardiac surgery in children
Gbadegesin, R., Zhao, S. G., Charpie, J. R., Brophy, P. D., Smoyer, W. E., & Lin, J. (2008) · Pediatric Nephrology · doi:10.1007/s00467-008-1047-z · Cited by 93 · cited 1×
“Adverse outcomes related to high levels of PFHb can be explained by its propensity to cause direct kidney injury because of renal tubular obstruction, the need for more blood transfusion with the risk of transfusion-related complications and even death in children requiring ECMO after cardiac surgery [13].”
BackgroundEvaluation of Outcome Scoring Systems for Patients on Extracorporeal Membrane Oxygenation
Lin, C., Tsai, F., Tian, Y., Jenq, C., Chen, Y., Fang, J., & Yang, C. (2007) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2007.05.045 · Cited by 88 · cited 1×
“Patients receiving ECMO support experience an approximate 60–75% in-hospital mortality rate [3–6] due to severity of the underlying pathology and high incidence of multiple organ failure, despite improvement in intensive care management and advances in ECMO hardware technology.”
BackgroundAcute Renal Failure after Cardiopulmonary Bypass Is Related to Decreased Serum Ferritin Levels
Davis, C. L., Kausz, A. T., Zager, R. A., Kharasch, E. D., & Cochran, R. P. (1999) · Journal of the American Society of Nephrology · doi:10.1681/asn.v10112396 · Cited by 64
Meyer, A. D. J., Wiles, A. A., Rivera, O., Wong, E. C. C., Freishtat, R. J., Rais-Bahrami, K., & Dalton, H. J. (2012) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0b013e31823c98ef · Cited by 57
Wu, M., Lin, P.-J., Tsai, F.-C., Haung, Y.-K., Liu, K., & Tsai, F. (2008) · Resuscitation · doi:10.1016/j.resuscitation.2008.05.002 · Cited by 54
A comparison study of haemolysis production in three contemporary centrifugal pumps
Bottrell, S., Bennett, M., Augustin, S., Thuys, C. A., Schultz, B., Horton, A. M., & Horton, S. (2014) · Perfusion · doi:10.1177/0267659113509000 · Cited by 39
Mumby, S. E., Koh, T. W., Pepper, J., & Gutteridge, J. M. C. (2001) · Biochimica et Biophysica Acta (BBA) - Molecular Basis of Disease · doi:10.1016/s0925-4439(01)00070-9 · Cited by 11 · cited 1×
“Moreover, the released iron (Fe) from hemolysis can result in Fe overload in 20% of the cases [22] which can lead to renal failure and increased lung permeability [23].”
Background
Cited by
2021 ELSO Adult and Pediatric Anticoagulation Guidelines
McMichael, A. B. V., Ryerson, L. M., Ratano, D., Fan, E., Faraoni, D., & Annich, G. M. (2022) · ASAIO Journal · doi:10.1097/mat.0000000000001652 · Cited by 437
Iron in the Tumor Microenvironment-Connecting the Dots
Pfeifhofer-Obermair, C., Tymoszuk, P., Petzer, V., Weiss, G., & Nairz, M. (2018) · Frontiers in Oncology · doi:10.3389/fonc.2018.00549 · Cited by 151
Metadata
- Authors
- Omar, H. R., Mirsaeidi, M., Socias, S., Sprenker, C., Caldeira, C., Camporesi, E. M., & Mangar, D.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2015-04-22
- Volume
- 10
- Issue
- 4
- Pages
- e0124034
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2055105222
- Cited by
- 170
- References
- 19
- FWCI
- 5.50
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.