SPEAR Trial: Smartphone Pediatric ElectrocARdiogram Trial
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: Smartphone-enabled ECG devices have the potential to improve patient care by enabling remote ECG assessment of patients with potential and diagnosed arrhythmias. This prospective study aimed to assess the usefulness of pediatric ECG tracings generated by the AliveCor device (Oklahoma City, OK) and to assess user satisfaction. STUDY DESIGN: Enrolled pediatric patients with documented paroxysmal arrhythmia used the AliveCor device over a yearlong study period. Pediatric electrophysiologists reviewed all transmitted ECG tracings. Patient completed surveys were analyzed to assess user satisfaction. RESULTS: 35 patients were enrolled with the following diagnoses: supraventricular tachycardia (SVT, 57%), atrial fibrillation (AF, 11%), ectopic atrial tachycardia (EAT, 6%), atrial tachycardia (AT, 3%), and ventricular tachycardia (VT, 23%). A total of 238 tracings were received from 20 patients, 96% of which were of diagnostic quality for sinus rhythm, sinus tachycardia, SVT, and AF. 126 patient satisfaction surveys (64% from parents) were completed. 98% of the survey responses indicated that it was easy to obtain tracings, 93% found it easy to transmit the tracings, 98% showed added comfort in managing arrhythmia by having the device, and 93% showed interest in continued use of the device after the study period ended. CONCLUSIONS: Smartphone-enabled ECG devices can generate tracings of diagnostic quality in children. User satisfaction was extremely positive. Use of the device to manage certain patients with AF and SVT showcases the future role of remote ECGs in the successful outpatient management of arrhythmias in children by potentially reducing Emergency Department visits and healthcare costs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) Trial
Crossley, G. H., Boyle, A., Vitense, H., Chang, Y., & Mead, R. H. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.12.012 · Cited by 526 · cited 1×
“Furthermore there is evidence that cardiac wireless remote monitoring with automatic clinician alerts reduces the time to a clinical decision in response to clinical events [9].”
BackgroundLau, J. K., Lowres, N., Neubeck, L., Brieger, D. B., Sy, R. W., Galloway, C. D., Albert, D. E., & Freedman, S. B. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.01.220 · Cited by 326
(2013) · Cited by 224
Ambulatory Arrhythmia Monitoring: Choosing the Right Device
Zimetbaum, P., & Goldman, A. (2010) · Circulation · doi:10.1161/circulationaha.109.925610 · Cited by 209
Smartphones and Pediatric Apps to Mobilize the Medical Home
Singh, A., Wilkinson, S., & Braganza, S. F. (2014) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2014.05.037 · Cited by 61
Report of the task force on children and youth. American Heart Association.
Moller, J. H., Allen, H. D., Clark, E. B., Dajani, A. S., Golden, A., Hayman, L. L., Lauer, R. M., Marmer, E. L., McAnulty, J. H., & Oparil, S. (1993) · Circulation · doi:10.1161/01.cir.88.5.2479 · Cited by 51
Tachycardia Detection Using Smartphone Applications in Pediatric Patients
Wackel, P. L., Beerman, L. B., West, L. J., & Arora, G. (2014) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2014.01.047 · Cited by 39
Comparison of 2 methods of measuring the QT interval
Rimmer, L. K., & Rimmer, J. (1998) · American Journal of Critical Care · doi:10.4037/ajcc1998.7.5.346 · Cited by 11
Cited by
Two new Later Stone Age sites from the Final Pleistocene in the Falémé Valley, eastern Senegal
Ndiaye, M., Lespez, L., Tribolo, C., Rassé, M., Hadjas, I., Davidoux, S., Huysecom, É., & Douze, K. (2024) · Monash University Research Portal (Monash University) · doi:10.3929/ethz-b-000667478 · Cited by 23,868
Steinberg, J. S., Varma, N., Cygankiewicz, I., Aziz, P., Balsam, P., Baranchuk, A., Cantillon, D. J., Dilaveris, P., Dubner, S. J., El-Sherif, N., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.03.038 · Cited by 303
Li, K. H. C., White, F. A., Tipoe, T., Liu, T., Wong, M. C. S., Jesuthasan, A., Baranchuk, A. M., Tse, G., & Yan, B. P. (2019) · JMIR mhealth and uhealth · doi:10.2196/11606 · Cited by 202
Clinical Validation of 5 Direct-to-Consumer Wearable Smart Devices to Detect Atrial Fibrillation
Mannhart, D., Lischer, M., Knecht, S., du Fay de Lavallaz, J., Strebel, I., Serban, T., Vögeli, D., Schaer, B., Osswald, S., Mueller, C., et al. (2023) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2022.09.011 · Cited by 175
Holter Monitoring and Loop Recorders: From Research to Clinical Practice
Galli, A., Ambrosini, F., & Lombardi, F. (2016) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2016.17.2 · Cited by 142
Metadata
- Authors
- Nguyen, H. H., Van Hare, G. F., Rudokas, M., Bowman, T., & Silva, J. N. A.
- Affiliations
- Washington University in St. Louis (US)
- Corresponding author
- Silva, Jennifer N. A.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2015-08-21
- Volume
- 10
- Issue
- 8
- Pages
- e0136256
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC4546652
- OpenAlex
- W1859007358
- Cited by
- 66
- References
- 8
- Citations by year
- 2026: 6 · 2025: 2 · 2024: 4 · 2023: 5 · 2022: 7 · 2021: 5 · 2020: 8 · 2019: 4 · 2018: 10 · 2017: 8 · 2016: 5 · 2015: 1
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Digital Commons@Becker (Washington University School of Medicine) (submittedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Keywords
- pediatric arrhythmia, paroxysmal arrhythmias, supraventricular tachycardia, atrial fibrillation, ventricular tachycardia, remote ECG monitoring, user satisfaction, ECG quality
- MeSH terms
- Smartphone, Adolescent, Atrial Fibrillation, Child, Child, Preschool, Electrocardiography, Female, Humans, Infant, Infant, Newborn, Male, Prospective Studies, Tachycardia, Ectopic Atrial, Tachycardia, Supraventricular, Patient Satisfaction, Tachycardia, Ventricular, Telemedicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.