Assessment of Lower Limb Muscle Strength and Power Using Hand-Held and Fixed Dynamometry: A Reliability and Validity Study
Open accessAbstract
INTRODUCTION: Hand-held dynamometry (HHD) has never previously been used to examine isometric muscle power. Rate of force development (RFD) is often used for muscle power assessment, however no consensus currently exists on the most appropriate method of calculation. The aim of this study was to examine the reliability of different algorithms for RFD calculation and to examine the intra-rater, inter-rater, and inter-device reliability of HHD as well as the concurrent validity of HHD for the assessment of isometric lower limb muscle strength and power. METHODS: 30 healthy young adults (age: 23±5 yrs, male: 15) were assessed on two sessions. Isometric muscle strength and power were measured using peak force and RFD respectively using two HHDs (Lafayette Model-01165 and Hoggan microFET2) and a criterion-reference KinCom dynamometer. Statistical analysis of reliability and validity comprised intraclass correlation coefficients (ICC), Pearson correlations, concordance correlations, standard error of measurement, and minimal detectable change. RESULTS: Comparison of RFD methods revealed that a peak 200 ms moving window algorithm provided optimal reliability results. Intra-rater, inter-rater, and inter-device reliability analysis of peak force and RFD revealed mostly good to excellent reliability (coefficients ≥ 0.70) for all muscle groups. Concurrent validity analysis showed moderate to excellent relationships between HHD and fixed dynamometry for the hip and knee (ICCs ≥ 0.70) for both peak force and RFD, with mostly poor to good results shown for the ankle muscles (ICCs = 0.31-0.79). CONCLUSIONS: Hand-held dynamometry has good to excellent reliability and validity for most measures of isometric lower limb strength and power in a healthy population, particularly for proximal muscle groups. To aid implementation we have created freely available software to extract these variables from data stored on the Lafayette device. Future research should examine the reliability and validity of these variables in clinical populations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Foundations of Clinical Research: Applications to Practice,
(2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00362-4 · Cited by 9,489
Terwee, C. B., Mokkink, L. B., Knol, D. L., Ostelo, R. W. J. G., Bouter, L. M., & de Vet, H. C. W. (2012) · Quality of Life Research · doi:10.1007/s11136-011-9960-1 · Cited by 1,978
Aagaard, P., Simonsen, E. B., Andersen, J. L., Magnusson, P., & Dyhre-Poulsen, P. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00283.2002 · Cited by 1,844
Invited Review: Aging and sarcopenia
Doherty, T. J. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00347.2003 · Cited by 1,764
Leg extensor power and functional performance in very old men and women.
Bassey, E. J., Fiatarone, M. A., O'neill, E. F., Kelly, M., Evans, W. J., & Lipsitz, L. A. (1992) · Clinical Science · doi:10.1042/cs0820321 · Cited by 943
Hand‐held Dynamometry Correlation With the Gold Standard Isokinetic Dynamometry: A Systematic Review
Stark, T., Walker, B., Phillips, J. K., Fejer, R., & Beck, R. (2011) · PM&R · doi:10.1016/j.pmrj.2010.10.025 · Cited by 816
Aagaard, P., Suetta, C., Caserotti, P., Magnusson, S. P., & Kjær, M. (2010) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2009.01084.x · Cited by 709
Andersen, L. L., & Aagaard, P. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0070-z · Cited by 657 · cited 1×
“Commonly used methods involve calculating the change in force over the change in time with discrete time intervals from the onset of contraction to 30, 50 or 100ms [5, 14, 15].”
MethodAssociation of Muscle Power With Functional Status in Community-Dwelling Elderly Women
Foldvari, M., Clark, M., Laviolette, L. C., Bernstein, M. A., Kaliton, D., Castaneda, C., Pu, C. T., Hausdorff, J. M., Fielding, R. A., & Singh, M. A. F. (2000) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/55.4.m192 · Cited by 653
Test-Retest Reliability of Hand-Held Dynamometry During a Single Session of Strength Assessment
Bohannon, R. W. (1986) · Physical Therapy · doi:10.1093/ptj/66.2.206 · Cited by 607
Energy Generation and Absorption at the Ankle and Knee during Fast, Natural, and Slow Cadences
WINTER, D. A. (1983) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198305000-00021 · Cited by 579
Clinical assessment of hip strength using a hand‐held dynamometer is reliable
Thorborg, K., Petersen, J., Magnusson, S. P., & Hölmich, P. (2010) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2009.00958.x · Cited by 518
Skelton, D. A. (2002) · Age and Ageing · doi:10.1093/ageing/31.2.119 · Cited by 504
Lower‐Extremity strength profiles in spastic cerebral palsy
Wiley, M. E., & Damiano, D. L. (1998) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.1998.tb15369.x · Cited by 491
Identification of elderly fallers by muscle strength measures
Pijnappels, M., van der Burg, (. J. C. E., Reeves, N. D., & van Dieën, J. H. (2008) · European Journal of Applied Physiology · doi:10.1007/s00421-007-0613-6 · Cited by 471
Maximal and explosive force production capacity and balance performance in men of different ages
Izquierdo, M., Aguado, X., Gonzalez, R., L�pez, J. L., & H�kkinen, K. (1999) · European Journal of Applied Physiology · doi:10.1007/s004210050504 · Cited by 373
Confidence in Altman–Bland plots: A critical review of the method of differences
Ludbrook, J. (2010) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.2009.05288.x · Cited by 366
Suetta, C., Aagaard, P., Rosted, A., Jakobsen, A. K., Duus, B., Kjaer, M., & Magnusson, S. P. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01307.2003 · Cited by 326
Hand-held Dynamometer Measurements: Tester Strength Makes a Difference
Wikholm, J. B., & Bohannon, R. W. (1991) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.1991.13.4.191 · Cited by 306
Aging, muscle fiber type, and contractile function in sprint-trained athletes
Korhonen, M. T., Cristea, A., Alén, M., Häkkinen, K., Sipilä, S., Mero, A., Viitasalo, J. T., Larsson, L., & Suominen, H. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00299.2006 · Cited by 302
Early and late rate of force development: differential adaptive responses to resistance training?
Andersen, L. L., Andersen, J. L., Zebis, M. K., & Aagaard, P. (2010) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2009.00933.x · Cited by 282
Kelln, B. M., McKeon, P. O., Gontkof, L. M., & Hertel, J. (2008) · Journal of Sport Rehabilitation · doi:10.1123/jsr.17.2.160 · Cited by 267
A Brief Review of Strength and Ballistic Assessment Methodologies in Sport
McMaster, D. T., Gill, N., Cronin, J., & McGuigan, M. (2014) · Sports Medicine · doi:10.1007/s40279-014-0145-2 · Cited by 264
Caserotti, P., Aagaard, P., Buttrup Larsen, J., & Puggaard, L. (2008) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2007.00732.x · Cited by 254 · cited 1×
“The latter has previously been quantified by calculating the rate of force development (RFD), which is calculated by measuring the change in force over a certain time period (Δforce/Δtime), usually during an isometric contraction [5, 6].”
MethodArnold, C. M., Warkentin, K. D., Chilibeck, P. D., & Magnus, C. R. A. (2010) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3181aa36b8 · Cited by 218
Pua, Y.-H., Wrigley, T. W., Cowan, S. M., & Bennell, K. L. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.10.028 · Cited by 205
Self-citationEffects of power training on muscle structure and neuromuscular performance
Kyröläinen, H., Avela, J., McBride, J. M., Koskinen, S., Andersen, J. L., Sipilä, S., Takala, T. E. S., & Komi, P. V. (2005) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2004.00390.x · Cited by 187
Reliability and validity assessment of a linear position transducer.
Garnacho‐Castaño, M. V., Lopez‐Lastra, S., & Maté‐Muñoz, J. L. (2015) · PubMed · Cited by 161
Isometric muscle force production as a function of age in healthy 20- to 74-yr-old men.
Bemben, M. G., Massey, B. H., Bemben, D. A., Je, M., & Boileau, R. A. (1991) · PubMed · Cited by 159
Sleivert, G. G., & Wenger, H. A. (1994) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/0003-9993(94)90279-8 · Cited by 155
Hip flexibility and strength measures: reliability and association with athletic groin pain
Malliaras, P., Hogan, A., Nawrocki, A., et al. (2009) · British Journal of Sports Medicine · doi:10.1136/bjsm.2008.055749 · Cited by 153
Moreau, N. G., Falvo, M. J., & Damiano, D. L. (2011) · Gait & Posture · doi:10.1016/j.gaitpost.2011.08.027 · Cited by 152
Measuring muscular strength of the lower limbs by hand-held dynamometer: A standard protocol
Bandinelli, S., Benvenuti, E., Lungo, I. D., Baccini, M., Benvenuti, F., Iorio, A. D., & Ferrucci, L. (1999) · Aging Clinical and Experimental Research · doi:10.1007/bf03339802 · Cited by 146
Bohannon, R. W., & Walsh, S. M. (1992) · PubMed · Cited by 145
Strength testing using hand-held dynamometry
Kolber, M. J., & Cleland, J. A. (2005) · Physical Therapy Reviews · doi:10.1179/108331905x55730 · Cited by 143
Asymmetry in Quadriceps Rate of Force Development as a Functional Outcome Measure in TKA
Maffiuletti, N. A., Bizzini, M., Widler, K., & Munzinger, U. (2010) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-009-0978-4 · Cited by 128
Taylor, N. F., Dodd, K., & Graham, H. K. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(03)00379-4 · Cited by 119
Blazevich, A. J., Horne, S., Cannavan, D., Coleman, D. R., & Aagaard, P. (2008) · Muscle & Nerve · doi:10.1002/mus.21021 · Cited by 104
Vanpee, G., Segers, J., Mechelen, H. V., Wouters, P. J., den Berghe, G. V., Hermans, G., & Gosselink, R. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e31821f050b · Cited by 103
Gerrits, K. H. L., Beltman, M. J., Koppe, P. A., Konijnenbelt, H., Elich, P., HAAN, A. D., & Janssen, T. W. J. (2009) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2008.09.562 · Cited by 99
Interdevice Reliability and Validity Assessment of the Nicholas Hand-Held Dynamometer
Trudelle-Jackson, E. J., Jackson, A. W., Frankowski, C. M., et al. (1994) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.1994.20.6.302 · Cited by 87
A portable, easily performed muscle power test and its association with falls by elderly persons
Fleming, B. E., Wilson, D. R., & Pendergast, D. R. (1991) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/0003-9993(91)90006-5 · Cited by 80
Reliability of handheld dynamometry in assessment of hip strength in adult male football players
Fulcher, M. L., Hanna, C. M., & Elley, C. R. (2009) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2008.11.007 · Cited by 76
Associations between lower limb strength and gait velocity following stroke: A systematic review
Mentiplay, B. F., Adair, B., Bower, K. J., Williams, G. P., Tolé, G., & Clark, R. A. (2014) · Brain Injury · doi:10.3109/02699052.2014.995231 · Cited by 70
Self-citationRELIABILITY ASSESSMENT OF BALLISTIC JUMP SQUATS AND BENCH THROWS
Alemany, J. A., Pandorf, C. E., Montain, S. J., Castellani, J. W., Tuckow, A. P., & Nindl, B. C. (2005) · The Journal of Strength and Conditioning Research · doi:10.1519/14783.1 · Cited by 64
Neuromuscular performance of paretic versus non-paretic plantar flexors after stroke
Fimland, M. S., Moen, P. M. R., Hill, T., Gjellesvik, T. I., Tørhaug, T., Helgerud, J., & Hoff, J. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-1934-z · Cited by 61
Quadriceps rate of force development affects gait and function in people with knee osteoarthritis
Winters, J. D., & Rudolph, K. S. (2013) · European Journal of Applied Physiology · doi:10.1007/s00421-013-2759-8 · Cited by 50
Davies, C. T. M., White, M. J., & Young, K. (1983) · European Journal of Applied Physiology · doi:10.1007/bf00952535 · Cited by 46
Villadsen, A., Roos, E. M., Overgaard, S., & Holsgaard‐Larsen, A. (2012) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e3182465ed0 · Cited by 43
Hand-held dynamometry: A practicable alternative for obtaining objective measures of muscle strength
Bohannon, R. W. (2012) · Isokinetics and Exercise Science · doi:10.3233/ies-2012-0476 · Cited by 35
Poulsen, E., Christensen, H. W., Penny, J. Ø., Overgaard, S., Vach, W., & Hartvigsen, J. (2012) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-13-242 · Cited by 33
Kaminski, T. W., Perrin, D. H., Mattacola, C. G., et al. (1995) · Journal of Sport Rehabilitation · doi:10.1123/jsr.4.3.210 · Cited by 18
Richardson, J. A., Stratford, P. W., & Cripps, D. (1998) · Physiotherapy Theory and Practice · doi:10.3109/09593989809070043 · Cited by 17
Cited by
The Biological Measurements of Mindfulness-based Stress Reduction: A Systematic Review
Reive, C. (2019) · EXPLORE · doi:10.1016/j.explore.2019.01.001 · Cited by 63
Vellios, E. E., Pinnamaneni, S., Camp, C. L., & Dines, J. S. (2020) · Current Reviews in Musculoskeletal Medicine · doi:10.1007/s12178-020-09645-9 · Cited by 17
Metadata
- Authors
- Mentiplay, B. F., Perraton, L. G., Bower, K. J., Adair, B., Pua, Y.-H., Williams, G. P., McGaw, R., & Clark, R. A.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2015-10-28
- Volume
- 10
- Issue
- 10
- Pages
- e0140822
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W1836189084
- Cited by
- 601
- References
- 53
- FWCI
- 13.23
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.