Evaluation of Transient Elastography, Acoustic Radiation Force Impulse Imaging (ARFI), and Enhanced Liver Function (ELF) Score for Detection of Fibrosis in Morbidly Obese Patients
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Liver fibrosis induced by non-alcoholic fatty liver disease causes peri-interventional complications in morbidly obese patients. We determined the performance of transient elastography (TE), acoustic radiation force impulse (ARFI) imaging, and enhanced liver fibrosis (ELF) score for fibrosis detection in bariatric patients. PATIENTS AND METHODS: 41 patients (median BMI 47 kg/m2) underwent 14-day low-energy diets to improve conditions prior to bariatric surgery (day 0). TE (M and XL probe), ARFI, and ELF score were performed on days -15 and -1 and compared with intraoperative liver biopsies (NAS staging). RESULTS: Valid TE and ARFI results at day -15 and -1 were obtained in 49%/88% and 51%/90% of cases, respectively. High skin-to-liver-capsule distances correlated with invalid TE measurements. Fibrosis of liver biopsies was staged as F1 and F3 in n = 40 and n = 1 individuals. However, variations (median/range at d-15/-1) of TE (4.6/2.6-75 and 6.7/2.9-21.3 kPa) and ARFI (2.1/0.7-3.7 and 2.0/0.7-3.8 m/s) were high and associated with overestimation of fibrosis. The ELF score correctly classified 87.5% of patients. CONCLUSION: In bariatric patients, performance of TE and ARFI was poor and did not improve after weight loss. The ELF score correctly classified the majority of cases and should be further evaluated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wong, V. W.-S., Vergniol, J., Wong, G. L.-H., Foucher, J., Chan, H. L.-Y., Le Bail, B., Choi, P. C.-L., Kowo, M., Chan, A. W.-H., Merrouche, W., et al. (2010) · Hepatology · doi:10.1002/hep.23312 · Cited by 1,322 · cited 1×
“Alternatively, non-invasive ultrasound techniques may be applied, which, however, are also limited by anthropometry of severely obese patients [1, 26, 27].”
Determination of reliability criteria for liver stiffness evaluation by transient elastography
Boursier, J., Zarski, J.-P., de Ledinghen, V., Rousselet, M.-C., Sturm, N., Lebail, B., Fouchard-Hubert, I., Gallois, Y., Oberti, F., Bertrais, S., et al. (2013) · Hepatology · doi:10.1002/hep.25993 · Cited by 662 · cited 1×
“1 kPa) were excluded from further analysis [21].”
Background
Cited by
Dietrich, C., Bamber, J., Berzigotti, A., Bota, S., Cantisani, V., Castera, L., Cosgrove, D., Ferraioli, G., Friedrich-Rust, M., Gilja, O., et al. (2017) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0043-103952 · Cited by 1,011
Self-citationMózes, F. E., Lee, J. A., Selvaraj, E. A., Jayaswal, A. N. A., Trauner, M., Boursier, J., Fournier, C., Staufer, K., Stauber, R. E., Bugianesi, E., et al. (2022) · Gut · doi:10.1136/gutjnl-2021-324243 · Cited by 556
Self-citationWong, V. W., Chan, W., Chitturi, S., Chawla, Y., Dan, Y. Y., Duseja, A., Fan, J., Goh, K., Hamaguchi, M., Hashimoto, E., et al. (2018) · Journal of Gastroenterology and Hepatology · doi:10.1111/jgh.13857 · Cited by 506
Selvaraj, E. A., Mózes, F. E., Jayaswal, A. N. A., Zafarmand, M. H., Vali, Y., Lee, J. A., Levick, C. K., Young, L. A. J., Palaniyappan, N., Liu, C.-H., et al. (2021) · Journal of Hepatology · doi:10.1016/j.jhep.2021.04.044 · Cited by 376
“…32±6 65 >1 6 (>2 years) Cui 2016 (USA)[84] SC, P, CS Biopsyproven NAFLD 125 49±15 46 32±7 26 1 1 FierbinteanuBraticevici 2013 (Romania)[90] SC, P, CS Biopsyproven NAFLD Simple steatosis: 21 47 40 29 - 1 (25 years) - NASH: 43 51 47 30 Joo 2018 (South Korea)[91] SC, P, CS Biopsyproven NAFLD 315 55…”
MethodVali, Y., Lee, J., Boursier, J., Spijker, R., Löffler, J., Verheij, J., Brosnan, M. J., Böcskei, Z., Anstee, Q. M., Bossuyt, P. M., et al. (2020) · Journal of Hepatology · doi:10.1016/j.jhep.2020.03.036 · Cited by 302
“We also assessed the effect of the test-biopsy time interval by removing studies with a long time interval between test and liver biopsy (mean: >12 months).(26,34) Heterogeneity was assessed based on visual assessment of forest plots and ROC curves.”
MethodResult
Metadata
- Authors
- Karlas, T., Dietrich, A., Peter, V., Wittekind, C., Lichtinghagen, R., Garnov, N., Linder, N., Schaudinn, A., Busse, H., Prettin, C., Keim, V., Tröltzsch, M., Schütz, T., & Wiegand, J.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2015-11-03
- Volume
- 10
- Issue
- 11
- Pages
- e0141649
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2125629104
- Cited by
- 64
- References
- 2
- FWCI
- 2.98
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of Transient Elastography, Acoustic Radiation Force Impulse Imaging (ARFI), and Enhanced Liver Function (ELF) Score for Detection of Fibrosis in Morbidly Obese Patients. https://app.cochat.ai/papers/10.1371/journal.pone.0141649
- The paper
- Karlas, T., Dietrich, A., Peter, V., Wittekind, C., Lichtinghagen, R., Garnov, N., Linder, N., Schaudinn, A., Busse, H., Prettin, C., Keim, V., Tröltzsch, M., Schütz, T., & Wiegand, J. (2015). Evaluation of Transient Elastography, Acoustic Radiation Force Impulse Imaging (ARFI), and Enhanced Liver Function (ELF) Score for Detection of Fibrosis in Morbidly Obese Patients. PLOS ONE. https://doi.org/10.1371/journal.pone.0141649
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.