Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 160

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Instrumental and Non-Instrumental Evaluation of 4-Meter Walking Speed in Older Individuals

Open access
Maggio, Marcello, Ceda, Gian Paolo, Ticinesi, Andrea, De Vita, Francesca, Gelmini, Giovanni, Costantino, Cosimo, Meschi, Tiziana, Kressig, Reto W., Cesari, Matteo, Fabi, Massimo, Lauretani, Fulvio · 2016 · PLOS ONE

Abstract

BACKGROUND: Manual measurement of 4-meter gait speed by a stopwatch is the gold standard test for functional assessment in older adults. However, the accuracy of this technique may be biased by several factors, including intra- and inter-operator variability. Instrumental techniques of measurement using accelerometers may have a higher accuracy. Studies addressing the concordance between these two techniques are missing. The aim of the present community-based observational study was to compare manual and instrumental measurements of 4-meter gait speed in older individuals and to assess their relationship with other indicators of physical performance. METHODS: One-hundred seventy-two (69 men, 103 women) non-disabled community-dwellers aged ≥65 years were enrolled. They underwent a comprehensive geriatric assessment including physical function by Short Physical Performance Battery (SPPB), hand grip strength, and 6-minute walking test (6MWT). Timed usual walking speed on a 4-meter course was assessed by using both a stopwatch (4-meter manual measurement, 4-MM) and a tri-axial accelerometer (4-meter automatic measurement, 4-MA). Correlations between these performance measures were evaluated separately in men and women by partial correlation coefficients. RESULTS: In both genders, 4-MA was associated with 4-MM (men r = 0.62, p<0.001; women r = 0.73, p<0.001), handgrip strength (men r = 0.40, p = 0.005; women r = 0.29, p = 0.001) and 6MWT (men r = 0.50, p = 0.0004; women r = 0.22, p = 0.048). 4-MM was associated with handgrip strength and 6MWT in both men and women. Considering gait speed <0.6 m/s as diagnostic of dismobility syndrome, the two methods of assessment disagreed, with a different categorization of subjects, in 19% of men and 23% of women. The use of accelerometer resulted in 29 (13 M, 16 F) additional diagnoses of dismobility, compared with the 4-MM. CONCLUSIONS: In an older population, the concordance of gait speeds manually or instrumentally assessed is not optimal. The results suggest that manual measures might lead to misclassification of a substantial number of subjects. However, longitudinal studies using standardized and validated procedures aimed at the comparison of different techniques are needed before recommending the use of accelerometers in comprehensive geriatric assessment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0153583

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 160

Metadata

Authors
Maggio, M., Ceda, G. P., Ticinesi, A., De Vita, F., Gelmini, G., Costantino, C., Meschi, T., Kressig, R. W., Cesari, M., Fabi, M., & Lauretani, F.
Venue
PLOS ONE
Published
2016-04-14
Volume
11
Issue
4
Pages
e0153583
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2336987540
Cited by
160
References
6
FWCI
24.61
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Instrumental and Non-Instrumental Evaluation of 4-Meter Walking Speed in Older Individuals. https://app.cochat.ai/papers/10.1371/journal.pone.0153583
The paper
Maggio, M., Ceda, G. P., Ticinesi, A., De Vita, F., Gelmini, G., Costantino, C., Meschi, T., Kressig, R. W., Cesari, M., Fabi, M., & Lauretani, F. (2016). Instrumental and Non-Instrumental Evaluation of 4-Meter Walking Speed in Older Individuals. PLOS ONE. https://doi.org/10.1371/journal.pone.0153583

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.