Single and Serial Fetal Biometry to Detect Preterm and Term Small- and Large-for-Gestational-Age Neonates: A Longitudinal Cohort Study
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: To assess the value of single and serial fetal biometry for the prediction of small- (SGA) and large-for-gestational-age (LGA) neonates delivered preterm or at term. METHODS: A cohort study of 3,971 women with singleton pregnancies was conducted from the first trimester until delivery with 3,440 pregnancies (17,334 scans) meeting the following inclusion criteria: 1) delivery of a live neonate after 33 gestational weeks and 2) two or more ultrasound examinations with fetal biometry parameters obtained at ≤36 weeks. Primary outcomes were SGA (<5th centile) and LGA (>95th centile) at birth based on INTERGROWTH-21st gender-specific standards. Fetus-specific estimated fetal weight (EFW) trajectories were calculated by linear mixed-effects models using data up to a fixed gestational age (GA) cutoff (28, 32, or 36 weeks) for fetuses having two or more measurements before the GA cutoff and not already delivered. A screen test positive for single biometry was based on Z-scores of EFW at the last scan before each GA cut-off so that the false positive rate (FPR) was 10%. Similarly, a screen test positive for the longitudinal analysis was based on the projected (extrapolated) EFW at 40 weeks from all available measurements before each cutoff for each fetus. RESULTS: Fetal abdominal and head circumference measurements, as well as birth weights in the Detroit population, matched well to the INTERGROWTH-21st standards, yet this was not the case for biparietal diameter (BPD) and femur length (FL) (up to 9% and 10% discrepancy for mean and confidence intervals, respectively), mainly due to differences in the measurement technique. Single biometry based on EFW at the last scan at ≤32 weeks (GA IQR: 27.4-30.9 weeks) had a sensitivity of 50% and 53% (FPR = 10%) to detect preterm and term SGA and LGA neonates, respectively (AUC of 82% both). For the detection of LGA using data up to 32- and 36-week cutoffs, single biometry analysis had higher sensitivity than longitudinal analysis (52% vs 46% and 62% vs 52%, respectively; both p<0.05). Restricting the analysis to subjects with the last observation taken within two weeks from the cutoff, the sensitivity for detection of LGA, but not SGA, increased to 65% and 72% for single biometry at the 32- and 36-week cutoffs, respectively. SGA screening performance was higher for preterm (<37 weeks) than for term cases (73% vs 46% sensitivity; p<0.05) for single biometry at ≤32 weeks. CONCLUSIONS: When growth abnormalities are defined based on birth weight, growth velocity (captured in the longitudinal analysis) does not provide additional information when compared to the last measurement for predicting SGA and LGA neonates, with both approaches detecting one-half of the neonates (FPR = 10%) from data collected at ≤32 weeks. Unlike for SGA, LGA detection can be improved if ultrasound scans are scheduled as close as possible to the gestational-age cutoff when a decision regarding the clinical management of the patient needs to be made. Screening performance for SGA is higher for neonates that will be delivered preterm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Villar, J., Ismail, L. C., Victora, C. G., Ohuma, E. O., Bertino, E., Altman, D. G., Lambert, A., Papageorghiou, A. T., Carvalho, M., Jaffer, Y. A., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(14)60932-6 · Cited by 2,281
In utero analysis of fetal growth: a sonographic weight standard
Hadlock, F. P., Harrist, R. B., & Martinez-Poyer, J. (1991) · Radiology · doi:10.1148/radiology.181.1.1887021 · Cited by 1,281
Practice guidelines for performance of the routine mid-trimester fetal ultrasound scan
Salomon, L. J., Alfirevic, Z., Berghella, V., Bilardo, C., Hernandez‐Andrade, E., Johnsen, S. L., Kalache, K., Leung, K. ‐., Malinger, G., Munoz, H., et al. (2011) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.8831 · Cited by 1,006
Self-citationPapageorghiou, A. T., Ohuma, E. O., Altman, D. G., Todros, T., Ismail, L. C., Lambert, A., Jaffer, Y. A., Bertino, E., Gravett, M. G., Purwar, M., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(14)61490-2 · Cited by 870
Racial/ethnic standards for fetal growth: the NICHD Fetal Growth Studies
Buck Louis, G. M., Grewal, J., Albert, P. S., Sciscione, A., Wing, D. A., Grobman, W. A., Newman, R. B., Wapner, R., D’Alton, M. E., Skupski, D., et al. (2015) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2015.08.032 · Cited by 532
Unterscheider, J., Daly, S., Geary, M. P., Kennelly, M. M., McAuliffe, F. M., O'Donoghue, K., Hunter, A., Morrison, J. J., Burke, G., Dicker, P., et al. (2013) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2013.02.007 · Cited by 464
Unterscheider, J., O’Donoghue, K., Daly, S., Geary, M. P., Kennelly, M. M., McAuliffe, F. M., Hunter, A., Morrison, J. J., Burke, G., Dicker, P., et al. (2014) · BMC Pregnancy and Childbirth · doi:10.1186/1471-2393-14-63 · Cited by 172
Cited by
ISUOG Practice Guidelines: ultrasound assessment of fetal biometry and growth
Salomon, L. J., Alfirevic, Z., Da Silva Costa, F., Deter, R. L., Figueras, F., Ghi, T., Glanc, P., Khalil, A., Lee, W., Napolitano, R., et al. (2019) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.20272 · Cited by 704
Diagnosis and surveillance of late-onset fetal growth restriction
Figueras, F., Caradeux, J., Crispi, F., Eixarch, E., Peguero, A., & Gratacos, E. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.12.003 · Cited by 300
Madden, J. V., Flatley, C. J., & Kumar, S. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2018.02.008 · Cited by 133
“found that there was no difference in SGA detection rates when single biometry was compared with serial measurements, with only modest impact on screening performance when maternal risk factors including diabetes mellitus and hypertension were accounted for.(21)”
ResultCaradeux, J., Martinez-Portilla, R. J., Peguero, A., Sotiriadis, A., & Figueras, F. (2019) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2018.09.043 · Cited by 122
Fetal growth velocity and body proportion in the assessment of growth
Hiersch, L., & Melamed, N. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.12.014 · Cited by 100
Metadata
- Authors
- Tarca, A. L., Hernandez-Andrade, E., Ahn, H., Garcia, M., Xu, Z., Korzeniewski, S. J., Saker, H., Chaiworapongsa, T., Hassan, S. S., Yeo, L., & Romero, R.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2016-11-01
- Volume
- 11
- Issue
- 11
- Pages
- e0164161
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2547021782
- Cited by
- 58
- References
- 7
- FWCI
- 10.28
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single and Serial Fetal Biometry to Detect Preterm and Term Small- and Large-for-Gestational-Age Neonates: A Longitudinal Cohort Study. https://app.cochat.ai/papers/10.1371/journal.pone.0164161
- The paper
- Tarca, A. L., Hernandez-Andrade, E., Ahn, H., Garcia, M., Xu, Z., Korzeniewski, S. J., Saker, H., Chaiworapongsa, T., Hassan, S. S., Yeo, L., & Romero, R. (2016). Single and Serial Fetal Biometry to Detect Preterm and Term Small- and Large-for-Gestational-Age Neonates: A Longitudinal Cohort Study. PLOS ONE. https://doi.org/10.1371/journal.pone.0164161
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.