Corneal confocal microscopy is a rapid reproducible ophthalmic technique for quantifying corneal nerve abnormalities
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PURPOSE: To assess the effect of applying a protocol for image selection and the number of images required for adequate quantification of corneal nerve pathology using in vivo corneal confocal microscopy (IVCCM). METHODS: IVCCM was performed in 35 participants by a single examiner. For each participant, 4 observers used a standardized protocol to select 6 central corneal nerve images to assess the inter-observer variability. Furthermore, images were selected by a single observer on two occasions to assess intra-observer variability and the effect of sample size was assessed by comparing 6 with 12 images. Corneal nerve fiber density (CNFD), branch density (CNBD) and length (CNFL) were quantified using fully automated software. The data were compared using the intra class correlation coefficient (ICC) and Bland-Altman agreement plots for all experiments. RESULTS: The ICC values for CNFD, CNBD and CNFL were 0.93 (P<0.0001), 0.96 (P<0.0001) and 0.95 (P<0.0001) for inter-observer variability and 0.95 (P<0.0001), 0.97 (P<0.001) and 0.97 (P<0.0001) for intra-observer variability. For sample size variability, ICC values were 0.94 (P<0.0001), 0.95 (P<0.0001), and 0.96 (P<0.0001) for CNFD, CNBD and CNFL. Bland-Altman plots showed excellent agreement for all parameters. CONCLUSIONS: This study shows that implementing a standardized protocol to select IVCCM images results in high intra and inter-observer reproducibility for all corneal nerve parameters and 6 images are adequate for analysis. IVCCM could therefore be deployed in large multicenter clinical trials with confidence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Azmi, S., Ferdousi, M., Petropoulos, I. N., Ponirakis, G., Alam, U., Fadavi, H., Asghar, O., Marshall, A., Atkinson, A. J., Jones, W., et al. (2015) · Diabetes Care · doi:10.2337/dc14-2733 · Cited by 148
Self-citation
Cited by
Selvarajah, D., Kar, D., Khunti, K., Davies, M. J., Scott, A. R., Walker, J., & Tesfaye, S. (2019) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(19)30081-6 · Cited by 556
Diabetic Peripheral Neuropathy: Epidemiology, Diagnosis, and Pharmacotherapy
Iqbal, Z., Azmi, S., Yadav, R., Ferdousi, M., Kumar, M., Cuthbertson, D. J., Lim, J., Malik, R. A., & Alam, U. (2018) · Clinical Therapeutics · doi:10.1016/j.clinthera.2018.04.001 · Cited by 487
Self-citationTFOS DEWS III: Diagnostic Methodology
Wolffsohn, J. S., Benítez-Del-Castillo, J. M., Loya-Garcia, D., Inomata, T., Iyer, G., Liang, L., Pult, H., Sabater, A. L., Starr, C. E., Vehof, J., et al. (2025) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2025.05.033 · Cited by 221
Diagnosing small fiber neuropathy in clinical practice: a deep phenotyping study
Egenolf, N., Altenschildesche, C. M. Z., Kreß, L., Eggermann, K., Namer, B., Gross, F., Klitsch, A., Malzacher, T., Kampik, D., Malik, R. A., et al. (2021) · Therapeutic Advances in Neurological Disorders · doi:10.1177/17562864211004318 · Cited by 72
Self-citationPreston, F. G., Meng, Y., Burgess, J., Ferdousi, M., Azmi, S., Petropoulos, I. N., Kaye, S., Malik, R. A., Zheng, Y., & Alam, U. (2022) · Diabetologia · doi:10.1007/s00125-021-05617-x · Cited by 70
“However, quantitative analysis of the subbasal nerve plexus requires reliable extraction of image features [14], and although manual segmentation of corneal nerve fibres is sensitive [15] and reproducible [16], it is operator-dependent and laborious.”
BackgroundSelf-citation
Metadata
- Authors
- Kalteniece, A., Ferdousi, M., Adam, S., Schofield, J., Azmi, S., Petropoulos, I., Soran, H., & Malik, R. A.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2017-08-17
- Volume
- 12
- Issue
- 8
- Pages
- e0183040
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2747293504
- Cited by
- 139
- References
- 2
- FWCI
- 9.66
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Corneal confocal microscopy is a rapid reproducible ophthalmic technique for quantifying corneal nerve abnormalities. https://app.cochat.ai/papers/10.1371/journal.pone.0183040
- The paper
- Kalteniece, A., Ferdousi, M., Adam, S., Schofield, J., Azmi, S., Petropoulos, I., Soran, H., & Malik, R. A. (2017). Corneal confocal microscopy is a rapid reproducible ophthalmic technique for quantifying corneal nerve abnormalities. PLOS ONE. https://doi.org/10.1371/journal.pone.0183040
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.