Validation of a light-scattering PM2.5 sensor monitor based on the long-term gravimetric measurements in field tests
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Portable direct-reading instruments by light-scattering method are increasingly used in airborne fine particulate matter (PM2.5) monitoring. However, there are limited calibration studies on such instruments by applying the gravimetric method as reference method in field tests. METHODS: An 8-month sampling was performed and 96 pairs of PM2.5 data by both the gravimetric method and the simultaneous light-scattering real-time monitoring (QT-50) were obtained from July, 2015 to February, 2016 in Shanghai. Temperature and relative humidity (RH) were recorded. Mann-Whitney U nonparametric test and Spearman correlation were used to investigate the differences between the two measurements. Multiple linear regression (MLR) model was applied to set up the calibration model for the light-scattering device. RESULTS: The average PM2.5 concentration (median) was 48.1μg/m3 (min-max 10.4-95.8μg/m3) by the gravimetric method and 58.1μg/m3 (19.2-315.9μg/m3) by the light-scattering method, respectively. By time trend analyses, they were significantly correlated with each other (Spearman correlation coefficient 0.889, P<0.01). By MLR, the calibration model for the light-scattering instrument was Y(calibrated) = 57.45 + 0.47 × X(the QT - 50 measurements) - 0.53 × RH - 0.41 × Temp with both RH and temperature adjusted. The 10-fold cross-validation R2 and the root mean squared error of the calibration model were 0.79 and 11.43 μg/m3, respectively. CONCLUSION: Light-scattering measurements of PM2.5 by QT-50 instrument overestimated the concentration levels and were affected by temperature and RH. The calibration model for QT-50 instrument was firstly set up against the gravimetric method with temperature and RH adjusted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wong, C.-M., Vichit-Vadakan, N., Kan, H., & Qian, Z. (2008) · Environmental Health Perspectives · doi:10.1289/ehp.11257 · Cited by 476
Self-citation
Cited by
Recent advances in sensor fault diagnosis: a review
Li, D., Wang, Y., Wang, J., Wang, C., & Duan, Y. (2020) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2020.111990 · Cited by 323
Direct and Indirect Effects of Indoor Particulate Matter on Blood Indicators Related to Anemia
Kwag, Y., Ye, S., Oh, J., Lee, D.-W., Yang, W., Kim, Y., & Ha, E. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph182412890 · Cited by 25
Effect of PM concentration on anemia blood indicators reduced by air purifiers
Kwag, Y., Oh, J., Yang, W., Kim, Y., Ha, E.-H., & Ye, S. (2023) · Chemosphere · doi:10.1016/j.chemosphere.2023.138131 · Cited by 11
Metadata
- Authors
- Shi, J., Chen, F., Cai, Y., Fan, S., Cai, J., Chen, R., Kan, H., Lu, Y., & Zhao, Z.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2017-11-09
- Volume
- 12
- Issue
- 11
- Pages
- e0185700
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2767701890
- Cited by
- 56
- References
- 1
- FWCI
- 1.81
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.