Economic evaluation of the one-hour rule-out and rule-in algorithm for acute myocardial infarction using the high-sensitivity cardiac troponin T assay in the emergency department
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The 1-hour (h) algorithm triages patients presenting with suspected acute myocardial infarction (AMI) to the emergency department (ED) towards "rule-out," "rule-in," or "observation," depending on baseline and 1-h levels of high-sensitivity cardiac troponin (hs-cTn). The economic consequences of applying the accelerated 1-h algorithm are unknown. METHODS AND FINDINGS: We performed a post-hoc economic analysis in a large, diagnostic, multicenter study of hs-cTnT using central adjudication of the final diagnosis by two independent cardiologists. Length of stay (LoS), resource utilization (RU), and predicted diagnostic accuracy of the 1-h algorithm compared to standard of care (SoC) in the ED were estimated. The ED LoS, RU, and accuracy of the 1-h algorithm was compared to that achieved by the SoC at ED discharge. Expert opinion was sought to characterize clinical implementation of the 1-h algorithm, which required blood draws at ED presentation and 1h, after which "rule-in" patients were transferred for coronary angiography, "rule-out" patients underwent outpatient stress testing, and "observation" patients received SoC. Unit costs were for the United Kingdom, Switzerland, and Germany. The sensitivity and specificity for the 1-h algorithm were 87% and 96%, respectively, compared to 69% and 98% for SoC. The mean ED LoS for the 1-h algorithm was 4.3h-it was 6.5h for SoC, which is a reduction of 33%. The 1-h algorithm was associated with reductions in RU, driven largely by the shorter LoS in the ED for patients with a diagnosis other than AMI. The estimated total costs per patient were £2,480 for the 1-h algorithm compared to £4,561 for SoC, a reduction of up to 46%. CONCLUSIONS: The analysis shows that the use of 1-h algorithm is associated with reduction in overall AMI diagnostic costs, provided it is carefully implemented in clinical practice. These results need to be prospectively validated in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Roffi, M., Patrono, C., Collet, J.-P., Mueller, C., Valgimigli, M., Andreotti, F., Bax, J. J., Borger, M. A., Brotons, C., Chew, D. P., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv320 · Cited by 8,261
Self-citation
Cited by
2023 ESC Guidelines for the management of acute coronary syndromes
Byrne, R. A., Rossello, X., Coughlan, J. J., Barbato, E., Berry, C., Chieffo, A., Claeys, M. J., Dan, G.-A., Dweck, M. R., Galbraith, M., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad191 · Cited by 5,333
Self-citationCollet, J.-P., Thiele, H., Barbato, E., Barthélémy, O., Bauersachs, J., Bhatt, D. L., Dendale, P., Dorobantu, M., Edvardsen, T., Folliguet, T., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa575 · Cited by 5,037
Self-citation2023 ESC Guidelines for the management of acute coronary syndromes
Byrne, R. A., Rossello, X., Coughlan, J. J., Barbato, E., Berry, C., Chieffo, A., Claeys, M. J., Dan, G.-A., Dweck, M. R., Galbraith, M., et al. (2024) · European Heart Journal: Acute Cardiovascular Care · doi:10.1093/ehjacc/zuad107 · Cited by 314
Self-citationClinical utility of magnetocardiography in cardiology for the detection of myocardial ischemia
Camm, A. J., Henderson, R., Brisinda, D., Body, R., Charles, R. G., Varcoe, B., & Fenici, R. (2019) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2019.07.009 · Cited by 42
Self-citation
Metadata
- Authors
- Ambavane, A., Lindahl, B., Giannitis, E., Roiz, J., Mendivil, J., Frankenstein, L., Body, R., Christ, M., Bingisser, R., Alquezar, A., Mueller, C., & for the TRAPID-AMI investigators
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2017-11-09
- Volume
- 12
- Issue
- 11
- Pages
- e0187662
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W4210411794
- Cited by
- 64
- References
- 1
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Economic evaluation of the one-hour rule-out and rule-in algorithm for acute myocardial infarction using the high-sensitivity cardiac troponin T assay in the emergency department. https://app.cochat.ai/papers/10.1371/journal.pone.0187662
- The paper
- Ambavane, A., Lindahl, B., Giannitis, E., Roiz, J., Mendivil, J., Frankenstein, L., Body, R., Christ, M., Bingisser, R., Alquezar, A., Mueller, C., & for the TRAPID-AMI investigators. (2017). Economic evaluation of the one-hour rule-out and rule-in algorithm for acute myocardial infarction using the high-sensitivity cardiac troponin T assay in the emergency department. PLOS ONE. https://doi.org/10.1371/journal.pone.0187662
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.