CoChat

3D multi-view convolutional neural networks for lung nodule classification

Open access

The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.

Abstract

The 3D convolutional neural network (CNN) is able to make full use of the spatial 3D context information of lung nodules, and the multi-view strategy has been shown to be useful for improving the performance of 2D CNN in classifying lung nodules. In this paper, we explore the classification of lung nodules using the 3D multi-view convolutional neural networks (MV-CNN) with both chain architecture and directed acyclic graph architecture, including 3D Inception and 3D Inception-ResNet. All networks employ the multi-view-one-network strategy. We conduct a binary classification (benign and malignant) and a ternary classification (benign, primary malignant and metastatic malignant) on Computed Tomography (CT) images from Lung Image Database Consortium and Image Database Resource Initiative database (LIDC-IDRI). All results are obtained via 10-fold cross validation. As regards the MV-CNN with chain architecture, results show that the performance of 3D MV-CNN surpasses that of 2D MV-CNN by a significant margin. Finally, a 3D Inception network achieved an error rate of 4.59% for the binary classification and 7.70% for the ternary classification, both of which represent superior results for the corresponding task. We compare the multi-view-one-network strategy with the one-view-one-network strategy. The results reveal that the multi-view-one-network strategy can achieve a lower error rate than the one-view-one-network strategy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0188290

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig 1 CT examples with lung nodules in different categories. They are benign (left), primary malignant (middle) and metastatic malignant (right), alone with 3 different view areas including 40×40, 50×50 and 60×60.
Fig 1 CT examples with lung nodules in different categories. They are benign (left), primary malignant (middle) and metastatic malignant (right), alone with 3 different view areas including 40×40, 50×50 and 60×60.CC BY · PubMed Central
Fig 2 Two kinds of the multi-view strategy. The one-view-one-network strategy (top) employs a separate network for images from each view (cropping size), while the multi-view-one-network strategy (bottom) uses one network for all views.
Fig 2 Two kinds of the multi-view strategy. The one-view-one-network strategy (top) employs a separate network for images from each view (cropping size), while the multi-view-one-network strategy (bottom) uses one network for all views.CC BY · PubMed Central
Fig 3 The architectures of the 3D single view CNN (SV-CNN) (top) and 3D MV-CNN (bottom).
Fig 3 The architectures of the 3D single view CNN (SV-CNN) (top) and 3D MV-CNN (bottom).CC BY · PubMed Central
Fig 4 The overall architecture of the 3D multi-view Inception network (left). This architecture applies to Inception1 and Inception2. The output sizes of each layer for the binary classification (middle) and the ternary classification (right) are different, which are also shown in this figure. Note that the output of each layer is a 5D tensor as described in the previous section. The details of the Inception module are shown in Fig 5.
Fig 4 The overall architecture of the 3D multi-view Inception network (left). This architecture applies to Inception1 and Inception2. The output sizes of each layer for the binary classification (middle) and the ternary classification (right) are different, which are also shown in this figure. Note that the output of each layer is a 5D tensor as described in the previous section. The details of the Inception module are shown in Fig 5.CC BY · PubMed Central
Fig 5 The detail of the Inception module in Fig 4: 3D Inception1 (left) and 3D Inception2 (right).
Fig 5 The detail of the Inception module in Fig 4: 3D Inception1 (left) and 3D Inception2 (right).CC BY · PubMed Central
Fig 6 The overall architecture of the Inception-ResNet network.
Fig 6 The overall architecture of the Inception-ResNet network.CC BY · PubMed Central
Fig 7 The process of generating 3D volume data.
Fig 7 The process of generating 3D volume data.CC BY · PubMed Central
Fig 8 The error rate of the 3D SV-CNN (top) and 3D MV-CNN (bottom) with chain architecture for the binary classification. From left to right, there are the error rates of Softmax, CNN1, CNN2 and CNN3, respectively.
Fig 8 The error rate of the 3D SV-CNN (top) and 3D MV-CNN (bottom) with chain architecture for the binary classification. From left to right, there are the error rates of Softmax, CNN1, CNN2 and CNN3, respectively.CC BY · PubMed Central
Fig 9 The error rate of the 3D SV-CNN (top) and 3D MV-CNN (bottom) with chain architecture for the ternary classification. From left to right, there are the error rates of Softmax, CNN1, CNN2 and CNN3, respectively.
Fig 9 The error rate of the 3D SV-CNN (top) and 3D MV-CNN (bottom) with chain architecture for the ternary classification. From left to right, there are the error rates of Softmax, CNN1, CNN2 and CNN3, respectively.CC BY · PubMed Central
Fig 10 The ROC curves of MV-softmax, 3D MV-CNN1 and 3D MV-inception1.
Fig 10 The ROC curves of MV-softmax, 3D MV-CNN1 and 3D MV-inception1.CC BY · PubMed Central
Fig 11 The number of parameters vs. training time and validation error rate for the binary classification (left) and the ternary classification (right). The area of the circles represents the corresponding validation error rate.
Fig 11 The number of parameters vs. training time and validation error rate for the binary classification (left) and the ternary classification (right). The area of the circles represents the corresponding validation error rate.CC BY · PubMed Central
Fig 12 The result of grid search for the binary (left) and ternary (right) classification.
Fig 12 The result of grid search for the binary (left) and ternary (right) classification.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 40 references

Cited by

See all 202

Metadata

Authors
Kang, G., Liu, K., Hou, B., & Zhang, N.
Affiliations
Beijing University of Posts and Telecommunications (CN)
Corresponding author
Liu, Kui
Venue
PLOS ONE
Published
2017-11-16
Volume
12
Issue
11
Pages
e0188290
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2770853452
Cited by
191
References
38
Citations by year
2026: 15 · 2025: 12 · 2024: 17 · 2023: 22 · 2022: 21 · 2021: 40 · 2020: 26 · 2019: 28 · 2018: 10
FWCI
10.44
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • National Natural Science Foundation of China (61471064)
  • National High Technology Research and Development Program of China (2015AA01A709)
Topics
  • Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
Keywords
lung nodule classification, 3D convolutional neural networks, chain architecture, benign versus malignant nodules, LIDC-IDRI, CT images
MeSH terms
Algorithms, Solitary Pulmonary Nodule, Humans, Lung Neoplasms, Tomography, X-Ray Computed, Neural Networks, Computer

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 3D multi-view convolutional neural networks for lung nodule classification. https://app.cochat.ai/papers/10.1371/journal.pone.0188290
The paper
Kang, G., Liu, K., Hou, B., & Zhang, N. (2017). 3D multi-view convolutional neural networks for lung nodule classification. PLOS ONE. https://doi.org/10.1371/journal.pone.0188290

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.