The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
A portable prototype magnetometer to differentiate ischemic and non-ischemic heart disease in patients with chest pain
Open accessAbstract
BACKGROUND: Magnetocardiography (MCG) is a non-invasive technique used to measure and map cardiac magnetic fields. We describe the predictive performance of a portable prototype magnetometer designed for use in acute and routine clinical settings. We assessed the predictive ability of the measurements derived from the magnetometer for the ruling-out of healthy subjects and patients whose chest pain has a non-ischemic origin from those with ischemic heart disease (IHD). METHODS: MCG data were analyzed from a technical performance study, a pilot clinical study, and a young healthy reference group. Participants were grouped to enable differentiation of those with IHD versus non-IHD versus controls: Group A (70 IHD patients); Group B (69 controls); Group C (37 young healthy volunteers). Scans were recorded in an unshielded room. Between-group differences were explored using analysis of variance. The ability of 10 candidate MCG predictors to predict normal/abnormal cases was analyzed using logistic regression. Predictive performance was internally validated using repeated five-fold cross-validation. RESULTS: Three MCG predictors showed a significant difference between patients and age-matched controls (P<0.001); eight predictors showed a significant difference between patients and young healthy volunteers (P<0.001). Logistic regression comparing patients with controls yielded a specificity of 35.0%, sensitivity of 95.4%, and negative predictive value for the ruling-out of IHD of 97.8% (area under the curve 0.78). CONCLUSION: This analysis represents a preliminary indication that the portable magnetometer can help rule-out healthy subjects and patients whose chest pain has a non-ischemic origin from those with IHD.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“A first pilot clinical study (protocol NCT02359773, on ClinicalTrials.gov) had shown that the device provided high sensitivity (95.4%) and a negative predictive value (NPV) (97.7%) for the rule-out of healthy subjects and of patients whose chest pain was non-ischemic from those with ischemic heart disease (262).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [262]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Writing Committee Members, Antman, E. M., Anbe, D. T., Armstrong, P. W., Bates, E. R., Green, L. A., Hand, M., Hochman, J. S., Krumholz, H. M., Kushner, F. G., et al. (2004) · Circulation · doi:10.1161/01.cir.0000134791.68010.fa · Cited by 8,356
2014 AHA/ACC Guideline for the Management of Patients With Non–ST-Elevation Acute Coronary Syndromes
Amsterdam, E. A., Wenger, N. K., Brindis, R. G., Casey, D. E., Ganiats, T. G., Holmes, D. R., Jaffe, A. S., Jneid, H., Kelly, R. F., Kontos, M. C., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.09.017 · Cited by 3,595
Internal validation of predictive models
Steyerberg, E. W., Harrell, F. E., Borsboom, G. J. J. M., Eijkemans, M. J. C., Vergouwe, Y., & Habbema, J. D. F. (2001) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(01)00341-9 · Cited by 2,746
Missed Diagnoses of Acute Cardiac Ischemia in the Emergency Department
Pope, J. H., Aufderheide, T. P., Ruthazer, R., Woolard, R. H., Feldman, J. A., Beshansky, J. R., Griffith, J. L., & Selker, H. P. (2000) · New England Journal of Medicine · doi:10.1056/nejm200004203421603 · Cited by 1,794
Early versus delayed invasive intervention in acute coronary syndromes
Mehta, S. R., Granger, C. B., Boden, W. E., Steg, P. G., Bassand, J.-P., Faxon, D. P., Afzal, R., Chrolavicius, S., Jolly, S. S., Widimsky, P., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0807986 · Cited by 925
A prospective validation of the HEART score for chest pain patients at the emergency department
Backus, B. E., Six, A. J., Kelder, J. C., Bosschaert, M. A. R., Mast, E. G., Mosterd, A., Veldkamp, R. F., Wardeh, A. J., Tio, R., Braam, R., et al. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.01.255 · Cited by 581
Clinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174
High-sensitive cardiac troponin T.
Xu, R., Zhu, X.-F., Yang, Y., & Ye, P. (2013) · 老年心脏病学杂志:英文版 · doi:10.3969/j.issn.1671-5411.2013.01.015 · Cited by 149
Hänninen, H., Takala, P., Mäkijärvi, M., Montonen, J., Korhonen, P., Oikarinen, L., Nenonen, J., Katila, T., & Toivonen, L. (2000) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2000.tb00380.x · Cited by 74
Yamada, S., & Yamaguchi, I. (2005) · Internal Medicine · doi:10.2169/internalmedicine.44.1 · Cited by 72
Research works printed but not linked: 2
- H Hänninen, 2000, Detection and localization of myocardial ischemia by multichannel magnetocardiography, Int J Bioelectromagnetism, 2
- FE Harrell Jr, 2015, Binary logistic regression. In: Regression Modeling Strategies, Springer Series in Statistics, 219
Cited by
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Survey of Transfer Learning Approaches in the Machine Learning of Digital Health Sensing Data
Chato, L., & Regentova, E. E. (2023) · Journal of Personalized Medicine · doi:10.3390/jpm13121703 · Cited by 79
Magnetocardiography for the detection of myocardial ischemia
Her, A., Dischl, D., Kim, Y. H., Kim, S., & Shin, E. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1242215 · Cited by 67
“(23) Logistic regression model based on 10 parameters measuring depolarization (QR_MMR, QR_interval, QR_angle, RS_MMR, RS_interval, RS_angle, QR_peak, QR_pd, RS_peak, and RS_pd) with a cut-off of 0.”
BackgroundMethodClinical utility of magnetocardiography in cardiology for the detection of myocardial ischemia
Camm, A. J., Henderson, R., Brisinda, D., Body, R., Charles, R. G., Varcoe, B., & Fenici, R. (2019) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2019.07.009 · Cited by 42
“These devices can be operated at room temperature with or without EMS, and may be portable (novel miniaturized induction coils), enabling the use of the device at the patient's bedside [13].”
BackgroundInfluentialSelf-citationHan, X., Pang, J., Xu, D., Wang, R., Xie, F., Yang, Y., Sun, J., Li, Y., Li, R., Yin, X., et al. (2023) · Physiological Measurement · doi:10.1088/1361-6579/ad0f70 · Cited by 25
Metadata
- Authors
- Ghasemi-Roudsari, S., Al-Shimary, A., Varcoe, B., Byrom, R., Kearney, L., & Kearney, M.
- Affiliations
- University of Leeds (GB)
- Corresponding author
- Al-Shimary, Abbas
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2018-01-19
- Volume
- 13
- Issue
- 1
- Pages
- e0191241
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC5774725
- OpenAlex
- W2785393919
- Cited by
- 19
- References
- 23
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 2 · 2023: 5 · 2022: 1 · 2021: 2 · 2020: 2 · 2019: 1 · 2018: 1
- FWCI
- 1.14
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- White Rose Research Online (University of Leeds, The University of Sheffield, University of York) (acceptedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Figshare (submittedVersion, cc-by)
- Funders
- Medical Technologies Innovation & Knowledge Centre
- Engineering and Physical Sciences Research Council (GB) (EP/G032483/1, EP/I019103/1, and EP/J017620/1)
- Creavo Medical Technologies Ltd., UK (formerly Quantum Imaging Ltd., UK)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- magnetocardiography, portable magnetometer, ischemic heart disease, chest pain, cardiac magnetic field, diagnostic accuracy, non-ischemic heart disease, cardiac biomarkers
- MeSH terms
- Non-ST Elevated Myocardial Infarction, Aged, Chest Pain, Diagnosis, Differential, Female, Heart Diseases, Humans, Male, Middle Aged, Pilot Projects, Predictive Value of Tests, Logistic Models, Case-Control Studies, Myocardial Ischemia, Magnetocardiography, Acute Coronary Syndrome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A portable prototype magnetometer to differentiate ischemic and non-ischemic heart disease in patients with chest pain. https://app.cochat.ai/papers/10.1371/journal.pone.0191241
- The paper
- Ghasemi-Roudsari, S., Al-Shimary, A., Varcoe, B., Byrom, R., Kearney, L., & Kearney, M. (2018). A portable prototype magnetometer to differentiate ischemic and non-ischemic heart disease in patients with chest pain. PLoS ONE. https://doi.org/10.1371/journal.pone.0191241
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.