CoChat

Implementation of intermittent theta burst stimulation compared to conventional repetitive transcranial magnetic stimulation in patients with treatment resistant depression: A cost analysis

Open access
Mendlowitz, Andrew B., Shanbour, Alaa, Downar, Jonathan, Vila-Rodriguez, Fidel, Daskalakis, Zafiris J., Isaranuwatchai, Wanrudee, Blumberger, Daniel M. · 2019 · PLOS ONE
Cited by 51

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Repetitive transcranial magnetic stimulation (rTMS) is an evidence-based treatment for depression that is increasingly implemented in healthcare systems across the world. A new form of rTMS called intermittent theta burst stimulation (iTBS) can be delivered in 3 min and has demonstrated comparable effectiveness to the conventional 37.5 min 10Hz rTMS protocol in patients with depression. OBJECTIVES: To compare the direct treatment costs per course and per remission for iTBS compared to 10Hz rTMS treatment in depression. METHODS: We conducted a cost analysis from a healthcare system perspective using patient-level data from a large randomized non-inferiority trial (THREE-D). Depressed adults 18 to 65 received either 10Hz rTMS or iTBS treatment. Treatment costs were calculated using direct healthcare costs associated with equipment, coils, physician assessments and technician time over the course of treatment. Cost per remission was estimated using the proportion of patients achieving remission following treatment. Deterministic sensitivity analyses and non-parametric bootstrapping was used to estimate uncertainty. RESULTS: From a healthcare system perspective, the average cost per patient was USD$1,108 (SD 166) for a course of iTBS and $1,844 (SD 304) for 10Hz rTMS, with an incremental net savings of $735 (95% CI 688 to 783). The average cost per remission was $3,695 (SD 552) for iTBS and $6,146 (SD 1,015) for 10Hz rTMS, with an average incremental net savings of $2,451 (95% CI 2,293 to 2,610). CONCLUSIONS: The shorter session durations and treatment capacity increase associated with 3 min iTBS translate into significant cost-savings per patient and per remission when compared to 10Hz rTMS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0222546

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

Metadata

Authors
Mendlowitz, A. B., Shanbour, A., Downar, J., Vila-Rodriguez, F., Daskalakis, Z. J., Isaranuwatchai, W., & Blumberger, D. M.
Venue
PLOS ONE
Published
2019-09-12
Volume
14
Issue
9
Pages
e0222546
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2972928338
Cited by
51
References
20
FWCI
1.67
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.