CoChat

Diagnostic performance of basal cortisol level at 0900-1300h in adrenal insufficiency

Open access

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: An ACTH stimulation test is the standard diagnostic test for adrenal insufficiency (AI). We aimed to investigate the diagnostic performance between serum morning (0800 h) cortisol and serum basal (0900-1300 h) cortisol levels and determine the proper cut-off point to facilitate AI diagnosis to reduce the number of tests. METHODS: A six-year retrospective study was performed in a tertiary care medical center. We identified 416 patients who had undergone either low (LDT) or high dose (HDT) ACTH stimulation outpatient tests. AI was defined as a peak serum cortisol level of <500 nmol/L at 30 or 60 minutes after LDT or HDT. The associations between AI and serum basal and morning cortisol levels were demonstrated by logistic regression model. Diagnostic performance was evaluated by ROC analysis. RESULTS: Of the 416 patients, 93 (22.4%) were categorized as having AI. The adjusted area under the curve (AUC) for the basal cortisol level for the diagnosis of AI was significantly higher than that for the morning cortisol (0.82 vs 0.69, p <0.001) level. The proposed cut-off values for the basal cortisol were <85 nmol/L (specificity 99.7%) and >350 nmol/L(sensitivity 98.9%). By using these proposed cut-off points, approximately 30% of the ACTH stimulation tests could be eliminated. CONCLUSION: The serum basal cortisol level with the proposed cut-off points were considered as an alternative option for diagnosis of AI. Utilizing the serum basal cortisol level can facilitate AI diagnosis as it is convenient, is not a time-specific test and has a high diagnostic performance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0225255

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig 1 Box plot graph of serum basal cortisol, serum morning cortisol, 30 and 60-minutes cortisol after ACTH stimulation test categorized by adrenal insufficiency status.
Fig 1 Box plot graph of serum basal cortisol, serum morning cortisol, 30 and 60-minutes cortisol after ACTH stimulation test categorized by adrenal insufficiency status.CC BY · PubMed Central
Fig 2 Covariate-adjusted AUCs of 0800 h serum morning cortisol and basal cortisol levels for the diagnosis of AI (adjusted for age, sex, serum albumin level, cholesterol level, creatinine level and ACTH dose).
Fig 2 Covariate-adjusted AUCs of 0800 h serum morning cortisol and basal cortisol levels for the diagnosis of AI (adjusted for age, sex, serum albumin level, cholesterol level, creatinine level and ACTH dose).CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 43

Metadata

Authors
Manosroi, W., Phimphilai, M., Khorana, J., & Atthakomol, P.
Affiliations
Chiang Mai University (TH)
Corresponding author
Manosroi, Worapaka
Venue
PLoS ONE
Published
2019-11-18
Volume
14
Issue
11
Pages
e0225255
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2986837945
Cited by
41
References
21
Citations by year
2026: 3 · 2025: 6 · 2024: 6 · 2023: 7 · 2022: 6 · 2021: 7 · 2020: 6
FWCI
3.85
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Greater South Information System
Funders
  • Chiang Mai University
  • Faculty of Medicine, Chiang Mai University
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Adrenal Hormones and Disorders
  • Life Sciences › Neuroscience › Behavioral Neuroscience › Stress Responses and Cortisol
  • Health Sciences › Medicine › Nephrology › Electrolyte and hormonal disorders
Keywords
adrenal insufficiency, basal cortisol, morning cortisol, ACTH stimulation test, diagnostic thresholds, diagnostic accuracy, serum cortisol
MeSH terms
Adolescent, Adrenal Insufficiency, Adrenocorticotropic Hormone, Adult, Aged, Aged, 80 and over, Female, Humans, Male, Middle Aged, Reference Values, Retrospective Studies, Time Factors, Biomarkers, Area Under Curve, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic performance of basal cortisol level at 0900-1300h in adrenal insufficiency. https://app.cochat.ai/papers/10.1371/journal.pone.0225255
The paper
Manosroi, W., Phimphilai, M., Khorana, J., & Atthakomol, P. (2019). Diagnostic performance of basal cortisol level at 0900-1300h in adrenal insufficiency. PLoS ONE. https://doi.org/10.1371/journal.pone.0225255

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.