New Cutoffs for the Biochemical Diagnosis of Adrenal Insufficiency after ACTH Stimulation using Specific Cortisol Assays

Open access
Javorsky, Bradley R, Raff, Hershel, Carroll, Ty B, Algeciras-Schimnich, Alicia, Singh, Ravinder Jit, Colón-Franco, Jessica M, Findling, James W · 2021 · Journal of the Endocrine Society

The DOI matches its Crossref record; 37 of the 39 references it cites were found in a registry or an index; 9 of the 54 sources its claims cite were checked for support.

Abstract

Context: The normal cortisol response 30 or 60 minutes after cosyntropin (ACTH[1–24]) is considered to be ≥18 μg/dL (500 nmol/L). This threshold is based on older serum cortisol assays. Specific monoclonal antibody immunoassays or LC-MS/MS may have lower thresholds for a normal response. Objective: To calculate serum cortisol cutoff values for adrenocorticotropic hormone (ACTH) stimulation testing with newer specific cortisol assays. Methods: Retrospective analysis of ACTH stimulation tests performed in ambulatory and hospitalized patients suspected of adrenal insufficiency (AI). Serum samples were assayed for cortisol in parallel using Elecsys I and Elecsys II immunoassays, and when volume was available, by Access immunoassay and LC-MS/MS. Results: A total of 110 patients were evaluated. Using 18 μg/dL as the cortisol cutoff after ACTH stimulation, 14.5%, 29%, 22.4%, and 32% of patients had a biochemical diagnosis of AI using the Elecsys I, Elecsys II, Access, and LC-MS/MS assays, respectively. Deming regressions of serum cortisol were used to calculate new cortisol cutoffs based on the Elecsys I cutoff of 18 μg/dL. For 30-minute values, new cutoffs were 14.6 μg/dL for Elecsys II, 14.8 μg/dL for Access, and 14.5 μg/dL for LC-MS/MS. Baseline cortisol <2 μg/dL was predictive of subnormal stimulated cortisol values. Conclusion: To reduce false positive ACTH stimulation testing, we recommend a new serum cortisol cutoff of 14 to 15 μg/dL depending on the assay used (instead of the historical value of 18 μg/dL with older polyclonal antibody assays). Clinicians should be aware of the new cutoffs for the assays available to them when evaluating patients for AI.

Overview

CoChat Summary

TL;DR

In 110 patients suspected of adrenal insufficiency, newer specific cortisol assays gave lower ACTH-stimulated cortisol values than the older Elecsys I polyclonal assay, so the historical 18 μg/dL cutoff produced more biochemical AI diagnoses. The authors recommend assay-specific post-cosyntropin cutoffs of 14 to 15 μg/dL to reduce false-positive ACTH stimulation tests.

Key findings

  • Using the historical 18 μg/dL cutoff, biochemical AI was diagnosed in 14.5% with Elecsys I, 29% with Elecsys II, 22.4% with Access, and 32% with LC-MS/MS.
  • Deming regression from the Elecsys I 18 μg/dL cutoff yielded 30-minute cutoffs of 14.6 μg/dL for Elecsys II, 14.8 μg/dL for Access, and 14.5 μg/dL for LC-MS/MS; 60-minute cutoffs were 14.7, 14.5, and 13.7 μg/dL, respectively.
  • Baseline cortisol <2 μg/dL was predictive of subnormal stimulated cortisol values, while values between 2 and 8 μg/dL overlapped substantially between normal and subnormal responders.
  • Discordant CST results occurred in 8 of 110 patients (7.3%) across assays using new cutoffs; most abnormal values were close to the cutoff, and clinical review identified secondary AI in 3 of these 8.

Methods

  • Retrospective analysis of residual serum samples from 110 ambulatory and hospitalized patients undergoing cosyntropin stimulation testing for suspected adrenal insufficiency from January 8, 2017 to April 30, 2017.
  • Cosyntropin (250 mcg ACTH[1–24]) was given intravenously, with serum cortisol measured before injection and at 30 minutes; 60-minute samples were analyzed when ordered. Samples were run in parallel on Elecsys I and Elecsys II, and when volume allowed, on Beckman Access and LC-MS/MS.
  • Deming regression was used to calculate new cutoffs from Elecsys I, with Bland-Altman bias analysis, ROC analysis, repeated-measures ANOVA, Mann-Whitney, and chi-square tests.

Limitations

  • The paper states there was no independent endocrine test to determine whether patients truly had AI, and many patients lacked long-term follow-up to confirm chronic AI or sustained glucocorticoid need.
  • The paper states the cohort came from diverse clinical settings and did not include a healthy subject cohort, though prior healthy-subject studies using specific assays found similar lower thresholds.
  • The paper notes CST interpretation is limited without pre-test probability and may be affected by serum protein levels, concurrent medications, and proper timely execution; evident from the text, this was a retrospective single-protocol study using residual samples, with some assays having smaller sample numbers because of insufficient serum volume.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1210/jendso/bvab022

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1. Deming regressions of serum cortisol by Roche Elecsys II, Beckman Access, and LC-MS/MS, compared with Elecsys I. Cortisol cutoff values for the 30- and 60-minute samples after ACTH (cosyntropin) stimulation were calculated from patients with baseline cortisol <18 μg/dL (500 nmol/L) on the Elecsys I assay. Confidence limit lines are 95%.
Figure 1. Deming regressions of serum cortisol by Roche Elecsys II, Beckman Access, and LC-MS/MS, compared with Elecsys I. Cortisol cutoff values for the 30- and 60-minute samples after ACTH (cosyntropin) stimulation were calculated from patients with baseline cortisol <18 μg/dL (500 nmol/L) on the Elecsys I assay. Confidence limit lines are 95%.CC BY-NC-ND · PubMed Central
Figure 2. Bland-Altman Plots of serum cortisol by Roche Elecsys II, Beckman Access, and LC-MS/MS compared with Elecsys I. Cortisol cutoff values for the 30- and 60-minute samples after ACTH (cosyntropin) stimulation were calculated from patients with baseline cortisol <18 μg/dL (500 nmol/L) on the Elecsys I assay. N values are the same as in Fig. 1. Bland-Altman parameters are shown in each panel. For the baseline data, the bias of LC-MS/MS cortisol was greater than for Elecsys II (P = 0.019). There were no differences in bias for 30-minute post-ACTH (cosyntropin) results. For the 60-min post-ACTH (cosyntropin) data, bias of LC-MS/MS cortisol was greater than Elecsys II (P = 0.009) and Access (P < 0.001).
Figure 2. Bland-Altman Plots of serum cortisol by Roche Elecsys II, Beckman Access, and LC-MS/MS compared with Elecsys I. Cortisol cutoff values for the 30- and 60-minute samples after ACTH (cosyntropin) stimulation were calculated from patients with baseline cortisol <18 μg/dL (500 nmol/L) on the Elecsys I assay. N values are the same as in Fig. 1. Bland-Altman parameters are shown in each panel. For the baseline data, the bias of LC-MS/MS cortisol was greater than for Elecsys II (P = 0.019). There were no differences in bias for 30-minute post-ACTH (cosyntropin) results. For the 60-min post-ACTH (cosyntropin) data, bias of LC-MS/MS cortisol was greater than Elecsys II (P = 0.009) and Access (P < 0.001).CC BY-NC-ND · PubMed Central
Figure 3. Comparison of baseline, 30-minute, and 60-minute cortisol values after ACTH (cosyntropin) stimulation in only those patients with data for all 3 time points within each assay method (paired repeated measures). a, different from 0 minutes within method. b, different from Elecsys I within same time point. c, different from 30 minutes within method. Numbers in parenthesis are N values.
Figure 3. Comparison of baseline, 30-minute, and 60-minute cortisol values after ACTH (cosyntropin) stimulation in only those patients with data for all 3 time points within each assay method (paired repeated measures). a, different from 0 minutes within method. b, different from Elecsys I within same time point. c, different from 30 minutes within method. Numbers in parenthesis are N values.CC BY-NC-ND · PubMed Central
Figure 4. Box-whisker plots of comparison of patients with baseline cortisol values <8 μg/dL on Elecsys I separated by whether they had a normal or subnormal response to ACTH (cosyntropin) stimulation. New cortisol cutoff values were used to determine the adequacy of response (cortisol value above the cutoff at the 30- or 60-minute time points). P values refer to differences between normal and subnormal response within each method. Abbreviations: Nml, normal; Abn, abnormal. N values for Nml and Abn are 8 and 13, respectively, for Elecsys I and Elecsys II. N values for Nml and Abn are 6-7 and 9-10, respectively, for Access and LCMS (LC-MS/MS).
Figure 4. Box-whisker plots of comparison of patients with baseline cortisol values <8 μg/dL on Elecsys I separated by whether they had a normal or subnormal response to ACTH (cosyntropin) stimulation. New cortisol cutoff values were used to determine the adequacy of response (cortisol value above the cutoff at the 30- or 60-minute time points). P values refer to differences between normal and subnormal response within each method. Abbreviations: Nml, normal; Abn, abnormal. N values for Nml and Abn are 8 and 13, respectively, for Elecsys I and Elecsys II. N values for Nml and Abn are 6-7 and 9-10, respectively, for Access and LCMS (LC-MS/MS).CC BY-NC-ND · PubMed Central

Verification

Claims the paper makes

5 Valid · 3 Not valid · 16 Not checked · 62 Own results and interpretations

53 more claims

Create a free account to see all 86 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 16
  • It may state two separate claims as one. 12

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 37 references

Cited by

See all 171

Metadata

Authors
Javorsky, B. R., Raff, H., Carroll, T. B., Algeciras-Schimnich, A., Singh, R. J., Colón-Franco, J. M., & Findling, J. W.
Affiliations
  • Froedtert Hospital (US)
  • Medical College of Wisconsin (US)
  • Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN 55905, USA
  • Mayo Clinic (US)
Corresponding author
Javorsky, Bradley R
Venue
Journal of the Endocrine Society
Published
2021-02-18
Volume
5
Issue
4
Pages
bvab022-bvab022
ISSN
2472-1972 (ISSN-L)
OpenAlex
W3132722879
Cited by
171
References
39
Citations by year
2026: 29 · 2025: 38 · 2024: 37 · 2023: 32 · 2022: 24 · 2021: 11
FWCI
17.85
Type
journal article
Language
en
Open access
Locations
  • Journal of the Endocrine Society (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
Funders
Advocate Aurora Research Institute
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Adrenal Hormones and Disorders
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Life Sciences › Neuroscience › Behavioral Neuroscience › Stress Responses and Cortisol
Keywords
adrenal insufficiency, ACTH stimulation test, monoclonal antibody assay, false positives, baseline cortisol

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-07, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-07 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: New Cutoffs for the Biochemical Diagnosis of Adrenal Insufficiency after ACTH Stimulation using Specific Cortisol Assays. https://app.cochat.ai/papers/10.1210/jendso/bvab022
The paper
Javorsky, B. R., Raff, H., Carroll, T. B., Algeciras-Schimnich, A., Singh, R. J., Colón-Franco, J. M., & Findling, J. W. (2021). New Cutoffs for the Biochemical Diagnosis of Adrenal Insufficiency after ACTH Stimulation using Specific Cortisol Assays. Journal of the Endocrine Society. https://doi.org/10.1210/jendso/bvab022

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.