CoChat

Cross-reactive carbohydrate determinant interference in cellulose-based IgE allergy tests utilizing recombinant allergen components

Open access
Sinson, Edsel, Ocampo, Camille, Liao, Cindy, Nguyen, Steven, Dinh, Lauren, Rodems, Kelline, Whitters, Eric, Hamilton, Robert G. · 2020 · PLOS ONE
Cited by 34

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Cross-reactive carbohydrate determinant (CCD) structures found in plant and insect glycoproteins are commonly recognized by IgE antibodies as epitopes that can lead to extensive cross-reactivity and obscure in vitro diagnostic (IVD) serology results. With the introduction of component resolved diagnosis (CRD), recombinant non-glycosylated components have been utilized to mitigate the risk of CCD-specific IgE (sIgE) detection. However, a recent study has shown that CCD-sIgE may bind directly to the cellulose solid phase matrix used in certain in vitro diagnostic assays, eliminating the advantage of CRD over traditional extract-based testing. The aim of this study is to further investigate the prevalence of CCD-sIgE interference on a commonly-used in vitro sIgE automated platform which employs a cellulose-based matrix to immobilize CCD-free recombinant components. METHODS: Sera from patients sensitized to peanut, silver birch, and/or timothy grass were analyzed for CCD-sIgE reactivity on ImmunoCAP/Phadia and NOVEOS autoanalyzers against the MUXF3 carbohydrate component. Positive CCD-sIgE sera were further analyzed against non-glycosylated recombinant components bound to the ImmunoCAP solid phase in the absence and presence of a soluble CCD inhibitor. For comparison, sera were then analyzed on NOVEOS, a non-cellulose based automated sIgE assay. RESULTS: Sera from 35% of the sensitized population tested in this study were positive (≥0.35 kU/L) for CCD-sIgE. Of those positives, 17% resulted in CCD-sIgE-positive (false positive) results on ImmunoCAP using non-glycosylated allergosorbents that were negative on NOVEOS. Sera producing false-positive results on ImmunoCAP had varying levels of CCD-sIgE from 0.67 kU/L to 36.52 kU/L. The incidence of CCD interference was predominantly delimited to low-positive IgE results (0.35 kUA/L- 3.00 kUA/L). CONCLUSION: Falsely elevated diagnostic allergen-sIgE results can commonly occur due to the presence of CCD-sIgE using assays that employ a carbohydrate matrix-based allergosorbent. Even the use of non-glycosylated recombinant allergenic components coupled to cellulose matrices do not reduce their risk of detection. The risk of CCD interference that compromises quantitative IgE results can be mitigated by the addition of a soluble CCD inhibitor to positive CCD-sIgE containing sera or by alternatively using a non-cellulose based sIgE assay, such as the NOVEOS assay.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0231344

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 34

Metadata

Authors
Sinson, E., Ocampo, C., Liao, C., Nguyen, S., Dinh, L., Rodems, K., Whitters, E., & Hamilton, R. G.
Venue
PLOS ONE
Published
2020-04-23
Volume
15
Issue
4
Pages
e0231344
ISSN
1932-6203 (ISSN-L)
OpenAlex
W3019710878
Cited by
34
References
3
FWCI
2.50
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.