The STARD Initiative and the Reporting of Studies of Diagnostic Accuracy
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
With the current public attention on medical tests (1), it is appropriate that we publish (2) this month, simultaneously with other journals,1 the first result of an international project to improve the reporting of studies of the diagnostic accuracy of medical tests. The report(2) on Standards for Reporting Diagnostic Accuracy (STARD) reflects a multidisciplinary effort, 3 years in the making, that involved close collaboration of scores of clinicians, clinical investigators, clinical chemists, radiologists, clinical microbiologists, methodologists, and others. I review here some of the evidence that studies of diagnostic accuracy of medical tests need improving and I suggest that the STARD report(2) is a step in the right direction. “Diagnostic accuracy” refers to the ability of a test to identify a condition of interest. In studies of diagnostic accuracy, the results of one or more tests are compared with a reference (“gold”) standard in a group of patients suspected of having the condition of interest. The term “accuracy” in this context thus refers to the amount of agreement between the studied test(s) and the reference standard. Studies of diagnostic accuracy are distinct from studies of analytical characteristics of a test, such as analytical accuracy, and distinct from studies of nonanalytical factors, such as within-person biological variation. Both of these types of studies provide essential information about tests, but they are not the focus here. Similarly, studies of diagnostic accuracy must be distinguished from studies of outcomes related to testing (such as improvements in health) and from studies of cost-effectiveness of testing. Quantitative understanding of the diagnostic accuracy of a test is critical both in deciding on its potential to improve outcomes and in assessing the results of a test in an individual patient. The term diagnostic accuracy is sometimes used in a broad sense of diagnosis (as above), but a good case can be made to use a more specific term when appropriate, e.g., prognostic accuracy for tests used in prognosis. There is need for improvement of these various types of studies of agreement between a test result and the relevant reference standard (gold standard), whether the reference standard is a current diagnosis or a state that is defined by subsequent events. In 1995, Reid et al. (3) documented the poor quality of studies of diagnostic accuracy. They examined the adherence to seven elementary standards of clinical epidemiology and reporting of results in 112 studies of diagnostic tests published in four major medical journals. More than one-half the studies were of tests performed in clinical laboratories. (Approximately one-third were radiologic.) None of the studies showed evidence of adherence to all seven standards of study design and reporting. The studies rarely provided such key information as the reproducibility of the examined test and whether the final diagnosis was made with or without knowledge of the results of the test being studied. Another report from Feinstein’s group (4) found similar problems in studies of genetic tests. In 1999, Lijmer et al. (5) demonstrated that such methodologic flaws mattered. They showed that published studies with these flaws were associated with more optimistic estimates of diagnostic accuracy than were studies without such flaws. It thus became obvious that reports of studies must include information about all potential threats to their validity. The inadequate reporting of studies of diagnostic accuracy has created an impasse for investigators attempting to do systematic reviews. Many published papers lack sufficient information even to calculate sensitivity-specificity pairs, which are needed to construct summary ROC curves (6). At a 1996 workshop on systematic reviewing of studies of diagnostic tests, Jon Deeks, Douglas Altman, and others identified for attendees additional problems with the primary studies that systematic reviewers encountered. Among these was the difficulty of assessing the extent to which results of a published study could be legitimately applied in a different setting. During the workshop, items that an editor should request from authors of primary studies became apparent. Concerned by the 1995 paper of Reid et al. (3), I had made a list of the seven standards that they studied and used it as a checklist when working with authors of reports submitted to Clinical Chemistry. The first manuscript to which this checklist was applied contained six of the seven items of information on the list. The missing item was the imprecision of the test—and this was a manuscript from an investigator in the field of clinical chemistry, a specialty for which assessment of imprecision of assays is a part of one’s being. The aphorism, “Mankind needs not so much to be educated as reminded”, came to mind. Other editors had become concerned with the quality of reporting of a different kind of clinical study, the randomize
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861
The STARD Statement for Reporting Studies of Diagnostic Accuracy: Explanation and Elaboration
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Moher, D., Rennie, D., de Vet, H. C. W., & Lijmer, J. G. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00012-w1 · Cited by 1,124
Self-citation
Cited by
Walsh, S. L. F., Calandriello, L., Silva, M., & Sverzellati, N. (2018) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(18)30286-8 · Cited by 390
The status of spectral EEG abnormality as a diagnostic test for schizophrenia
Boutros, N. N., Arfken, C., Galderisi, S., Warrick, J., Pratt, G., & Iacono, W. (2008) · Schizophrenia Research · doi:10.1016/j.schres.2007.11.020 · Cited by 322
Algorithms for digital image processing in diabetic retinopathy
Winder, R. J., Morrow, P. J., McRitchie, I. N., Bailie, J. R., & Hart, P. M. (2009) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2009.06.003 · Cited by 248
Hepcidin in Human Iron Disorders: Diagnostic Implications
Kroot, J. J., Tjalsma, H., Fleming, R. E., & Swinkels, D. W. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2009.140053 · Cited by 246
Immunoassays for Testosterone in Women: Better than a Guess?
Herold, D. A., & Fitzgerald, R. L. (2003) · Clinical Chemistry · doi:10.1373/49.8.1250 · Cited by 203
The US Food and Drug Administration perspective on cancer biomarker development
Gutman, S., & Kessler, L. G. (2006) · Nature Reviews Cancer · doi:10.1038/nrc1911 · Cited by 176
Circulating Biomarkers of Cognitive Decline and Dementia
Solfrizzi, V., D'Introno, A., Colacicco, A. M., Capurso, C., Todarello, O., Pellicani, V., Capurso, S. A., Pietrarossa, G., Santamato, V., Capurso, A., et al. (2006) · Clinica Chimica Acta · doi:10.1016/j.cca.2005.06.015 · Cited by 120
The DEX/CRH test for major depression: A potentially useful diagnostic test
Mokhtari, M., Arfken, C., & Boutros, N. (2013) · Psychiatry Research · doi:10.1016/j.psychres.2012.09.032 · Cited by 79
“, 2009), based on the previously published guidelines for deciding the clinical usefulness of diagnostic tests (Sackett, 1991) and the criteria of the Standards for Reporting of Diagnostic Accuracy (STARD) (Bruns, 2003; Bossuyt et al., 2003).”
Method
Metadata
- Authors
- Bruns, D. E.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-01-01
- Volume
- 49
- Issue
- 1
- Pages
- 19-20
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2055619791
- Cited by
- 36
- References
- 2
- FWCI
- 4.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.