Lupus Anticoagulant (LA) Testing: Performance of Clinical Laboratories Assessed by a National Survey Using Lyophilized Affinity-purified Immunoglobulin with LA Activity
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Background: Lupus anticoagulant (LA) screens are frequently ordered in the workup of thrombophilic patients or women with fetal loss. The sensitivity and specificity of LA detection vary depending on the choice of tests, cutoff values, and results interpretation. This variation is detrimental to patient management because persistent LA positivity in patients with a history of thrombosis is a requisite for long-term anticoagulation therapy. Numerous surveys have been performed to assess the state of the art for LA diagnosis. The control plasmas used in these surveys were from LA-positive or -negative patients or were normal plasmas with monoclonal antibodies against human β2-glycoprotein I (β2-GPI) added. Methods: A large number of laboratories were asked to test a common set of lyophilized plasmas for LA, including three normal plasmas, to which increasing amounts of affinity-purified IgG from a patient positive for anti-β2-GPI had been added, and three LA-negative plasmas: one normal, one with a coagulation deficiency, and one with heparin. Results: Overall, 69, 68, and 59 of 70 participants were able to detect LA in plasmas with high, intermediate, and low potency (sensitivity, 99%, 97%, and 84%). Conversely, 69, 50, and 53 of 70 were able to rule out LA in the normal, heparinized, and deficient plasma (specificity, 99%, 71%, and 76%). Conclusions: Sensitivity for LA detection is satisfactory, whereas specificity could be improved. Surveys for LA detection should be carried out on a regular basis because they may help improve performance. Plasmas containing graded amounts of affinity-purified human anti-β2-GPI may be used as a convenient source of well-characterized naturally occurring LA material.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brandt, J. T., Triplett, D. A., Alving, B., & Scharrer, I. (1995) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1649901 · Cited by 993
Galli, M., Luciani, D., Bertolini, G., & Barbui, T. (2003) · Blood · doi:10.1182/blood-2002-02-0441 · Cited by 972
Guidelines on the investigation and management of antiphospholipid syndrome
Keeling, D., Mackie, I., Moore, G. W., Greer, I. A., Greaves, M., & British Committee for Standards in Haematology (2012) · British Journal of Haematology · doi:10.1111/j.1365-2141.2012.09037.x · Cited by 740
Wahl, D., Guillemin, F., de Maistre, E., Perret, C., Lecompte, T., & Thibaut, G. (1997) · Lupus · doi:10.1177/096120339700600510 · Cited by 285
Rai, R. S., Regan, L., Clifford, K., Pickering, W., Dave, M., Mackie, I., McNally, T., & Cohen, H. (1995) · Human Reproduction · doi:10.1093/oxfordjournals.humrep.a136224 · Cited by 238
Biasiolo, A., Rampazzo, P., Brocco, T., & Pengo, V. (1999) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1614453 · Cited by 76
Self-citationJennings, I., Greaves, M., Mackie, I. J., Kitchen, S., Woods, T. A. L., Preston, F. E., & ation, O. B. O. T. U. N. E. Q. A. S. F. B. C. (2002) · British Journal of Haematology · doi:10.1046/j.1365-2141.2002.03821.x · Cited by 72 · cited 1×
“Proficiency testing programs should be carried out on a regular basis because these may help in improving performance, especially when they are implemented in combination with the dissemination of guidelines on laboratory procedures ( 13 ). In this respect, plasmas enriched with graded amounts of affinity-purified hum…”
Background
Cited by
MIYAKIS, S., LOCKSHIN, M. D., ATSUMI, T., BRANCH, D. W., BREY, R. L., CERVERA, R., DERKSEN, R. H. W. M., DE GROOT, P. G., KOIKE, T., MERONI, P. L., et al. (2006) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2006.01753.x · Cited by 7,203
Update of the guidelines for lupus anticoagulant detection
PENGO, V., TRIPODI, A., REBER, G., RAND, J. H., ORTEL, T. L., GALLI, M., & DE GROOT, P. G. (2009) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2009.03555.x · Cited by 1,197
Self-citationDevreese, K. M. J., de Groot, P. G., de Laat, B., Erkan, D., Favaloro, E. J., Mackie, I., Martinuzzo, M., Ortel, T. L., Pengo, V., Rand, J. H., et al. (2020) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.15047 · Cited by 467
Self-citationTripodi, A., Cohen, H., & Devreese, K. M. J. (2020) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.14846 · Cited by 169
Self-citation
Metadata
- Authors
- Tripodi, A., Biasiolo, A., Chantarangkul, V., & Pengo, V.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-10-01
- Volume
- 49
- Issue
- 10
- Pages
- 1608-1614
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2144746872
- Cited by
- 65
- References
- 7
- FWCI
- 2.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.