CoChat

Liquid Chromatography–Tandem Mass Spectrometry Analysis of Urinary Free Cortisol

Open access
Kushnir, Mark M, Rockwood, Alan L, Nelson, Gordon J, Terry, Alan H, Meikle, A Wayne · 2003 · Clinical Chemistry
Cited by 70

The DOI matches its Crossref record.

Abstract

For the analysis of urinary free cortisol (UFC), liquid chromatography (LC), LC-mass spectrometry (LC-MS), and liquid chromatography-tandem MS (LC-MS/MS) offer better specificity and accuracy of result than immunoassay-based methods (1). The high specificity of LC-MS/MS provides simplification of sample preparation, reduced costs, increased sample throughput, and a low rate of sample interference. Published approaches to LC-MS/MS analysis of UFC use either sample extraction (1) or direct sample injection (2). The direct methods reduce the labor requirements and decrease the potential for human error. We have developed a direct sample injection method similar to one published by Nassar et al. (2). The primary changes in the proposed method are the use of a guard cartridge for trapping cortisol as part of an online purification strategy and the use of step gradient rather than isocratic LC conditions. Both electrospray ionization (ESI) and atmospheric pressure ionization (APCI) are well suited for LC-MS/MS. We used APCI because preliminary experiments demonstrated a two- to threefold increase in sensitivity compared with ESI. Better sensitivity for cortisol with an APCI interface compared with ESI can be explained by the poor ionization of cortisol in solution. Cortisol and ammonium formate were purchased from Sigma, and d4-cortisol was purchased from Cambridge Isotope Laboratories. Methanol (HPLC grade) was purchased from Fisher Scientific. Patient samples were analyzed for cortisol within 1–3 days after collection. All studies with samples from humans were approved by the Institutional Review Board of the University of Utah. Sample preparation for the method was performed as follows. A 500-μL aliquot of centrifuged urine sample and 100 μL of the working internal standard (IS; d4-cortisol, 0.5 mg/L) were added to autosampler vials, and the vials were vortex-mixed. A PE series 200 HPLC system (Perkin-Elmer Analytical Instruments) was equipped with a Luna C18 column [50 × 2.0 mm (i.d.); 5 μm particles; Phenomenex]. Sample trapping and purification was performed online with a C18 guard cartridge (Phenomenex). Urine with IS was injected with mobile phase consisting of methanol–5 mmol/L ammonium formate (7:93 by volume). The cartridge was washed for 0.5 min to remove hydrophilic constituents. After 0.5 min, the mobile phase composition was changed by step gradient to 55:45 methanol–5 mmol/L ammonium formate, and the column effluent was directed to the LC column connected to a MS interface. The column temperature was 40 °C, the injection volume was 200 μL, and the injection interval was 8 min. The autosampler syringe wash solvent was methanol–water (80:20 by volume) containing 8 mmol/L trifluoroacetic acid. An API 2000 (Applied Biosystems/MDS SCIEX) tandem mass spectrometer was used in the positive-ion mode with an APCI interface. Quantitative analysis was performed in the multiple-reaction monitoring mode, and the transitions monitored were m/z 363→121 and 363→97 for cortisol and m/z 367→121 and 367→97 for d4-cortisol. Quantification was performed based on the m/z 121 product ion, whereas the m/z 97 product ion was used for confirmation of cortisol and d4-cortisol identity. The collision gas was nitrogen with a collision cell pressure of 1.1 Pa. The APCI needle current was 2.0 μA, the orifice voltage was 60 V, and the collision energy was 24 V for the m/z 363→121 and 367→121 transitions and 52 V for the m/z 363→97 and 367→97 transitions. Quantitative data analysis was performed with TurboQuanTM (Applied Biosystems/MDS SCIEX) software. The calibrators were prepared at 10, 50, 100, and 200 μg/L in a solution prepared by dissolving 16 mmol of potassium hydrogen phosphate, 5 mmol of sodium dihydrogen phosphate, 60 mmol of sodium chloride, 340 mmol of urea, and 9 mmol of creatinine in 1 L of deionized water. The 50 μg/L calibrator was used to establish a qualitative intensity ratio of the product ion fragments for cortisol and d4-cortisol. For cortisol, the ratio was the intensity of the m/z 363→97 transition divided by the intensity of the m/z 363→121 transition. For d4-cortisol, the ratio was the intensity of the m/z 367→97 transition divided by the intensity of the m/z 367→121 transition. The acceptability limits for qualitative ion intensity ratio for the controls and test samples were set at ±40% of the values established with the calibrator. Monitoring of at least two MS/MS transitions allows detection of interferences. A ratio above the allowable upper limit indicated interference at the m/z 363→121 transition, in which case quantification was performed using the m/z 363→97 transition. Within-run imprecision of triplicate analyses of human urine samples supplemented with cortisol to concentrations of 10, 43, and 75 μg/L was <5.8%, between-run imprecision for the samples analyzed over 5 days was <6.5%, and total imprecision was <8.5%. The limit of quantification (2 μg/L) was determined as the lowest concentratio

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/49.6.965

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 70

Metadata

Authors
Kushnir, M. M., Rockwood, A. L., Nelson, G. J., Terry, A. H., & Meikle, A. W.
Venue
Clinical Chemistry
Published
2003-06-01
Volume
49
Issue
6
Pages
965-967
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2032149805
Cited by
70
References
0
FWCI
1.82
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Liquid Chromatography–Tandem Mass Spectrometry Analysis of Urinary Free Cortisol. https://app.cochat.ai/papers/10.1373/49.6.965
The paper
Kushnir, M. M., Rockwood, A. L., Nelson, G. J., Terry, A. H., & Meikle, A. W. (2003). Liquid Chromatography–Tandem Mass Spectrometry Analysis of Urinary Free Cortisol. Clinical Chemistry. https://doi.org/10.1373/49.6.965

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.