Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 324

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Proteomic Patterns in Biological Fluids: Do They Represent the Future of Cancer Diagnostics?

Diamandis, Eleftherios P·2003·Clinical Chemistry

Abstract

Writing on the future of cancer diagnostics, this author has predicted that multiparametric biomarker analysis, in combination with artificial neural networks and pattern recognition, will likely represent one of the most promising methodologies for diagnosing and monitoring cancer (1)(2). Over the last few years, we have witnessed publication of many reports dealing with proteomic patterns in biological fluids, and especially serum, by using the so-called “SELDI-TOF” technique (surface-enhanced laser desorption/ionization time-of-flight mass spectrometry), in combination with artificial intelligence (3)(4)(5)(6)(7). The reported sensitivities and specificities of this method for ovarian, prostate, and breast cancer diagnosis are clearly impressive, and they are superior to the sensitivities and specificities obtained with current serologic cancer biomarkers (8)(9)(10)(11)(12). In particular, these techniques appear to detect early as well as advanced disease with similar efficiency, making them candidate tools for cancer screening, an application that is not currently recommended, by utilizing the classical cancer biomarkers, e.g., CA125, carcinoembryonic antigen (CEA), and α-fetoprotein (AFP) (1). In addition to scientific journals, these reports have also been presented in international news media and have attracted public attention. Despite of some important shortcomings of these methodologies, criticism has been minimal (13)(14). It seems that the impressive bottom line (very high diagnostic sensitivity and specificity) overshadows potential problems. The recent publication of three reports, from two different research groups, on the use of this technology in the diagnosis of prostate cancer allows for comparison of the data and the methodology and for the presentation of some important questions that have not been adequately addressed. In the following paragraphs, I will focus on some critical questions and provide discussion that could form the basis for further investigations. I will concentrate only on prostate cancer, but the same questions are likely valid for ovarian and other cancers. Adam et al. (10) report 83% sensitivity at 97% specificity for prostate cancer detection, whereas Petricoin et al. (9) report 95% sensitivity at 78–83% specificity. Qu et al. (12) reported 97–100% sensitivity at 97–100% specificity. I consider these data roughly comparable, impressive, and clearly superior to the specificity obtained by prostate-specific antigen (PSA) testing (∼ 25%) at the same sensitivities (15). However, it is surprising that the two groups in three studies obtained these results using different methodologies and distinguishing peaks (Table 1 ). Adam et al. (10) and Qu et al.(12) (the same research group) used an IMAC-Cu metal-binding chip for serum adsorption after evaluating other types of chips, including hydrophobic, ionic, cationic, and metal binding. Petricoin et al. (9) found that a hydrophobic C-16 chip was superior. Furthermore, Adam et al. (10) used nine peaks at m/z ratios of 4475, 5074, 5382, 7024, 7820, 8141, 9149, 9507, and 9656, whereas Petricoin et al. (9) selected different peaks at m/z ratios of 2092, 2367, 2582, 3080, 4819, 5439, and 18220. Qu et al. (12) identified 12 major peaks at m/z ratios of 9656, 9720, 6542, 6797, 6949, 7024, 8067, 8356, 3963, 4080, 7885, and 6991 for differentiating noncancer from cancer and 9 peaks at m/z ratios of 7820, 4580, 7844, 4071, 7054, 5298, 3486, 6099, and 8943 for differentiating healthy individuals from patients with benign prostatic hyperplasia. It should be surprising that none of the peaks identified by Petricoin et al. (9) were identified by either Adam et al.(10) or Qu et al. (12)). Even more surprising is the fact that although Adam et al. (10) and Qu et al.(12) used the same chip for serum extraction and the same instrument for peak identification, their distinguishing peaks are very different. Notably, only two peaks are the same, at m/z ratios of 7024 and 9656 (Table 1 ). Another peak, at a m/z ratio of 7820, was identified by Adam et al. (10) as distinguishing for cancer vs noncancer patients and by Qu et al. (12) as distinguishing between healthy individuals and patients with benign prostatic hyperplasia, but not between noncancer and cancer patients. One (albeit very unlikely) explanation to this finding is that there must be thousands of potential distinguishing peaks in serum and that the chance of two groups finding the same peaks would be very low. Another, more likely explanation is that the methods for extracting these potential molecules from serum are very sensitive to the experimental details or to serum storage conditions, even if the same extraction devices are used. Comparison of three reports for prostate cancer diagnosis based on SELDI-TOF technology. m/z ratios were rounded to whole numbers for simplicity. m/z ratios in bold font represent those identified by Adam et al. (10) and Qu et al. (12) for differentiati

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/49.8.1272

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 324

Metadata

Authors
Diamandis, E. P.
Venue
Clinical Chemistry
Published
2003-08-01
Volume
49
Issue
8
Pages
1272-1275
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2102342618
Cited by
324
References
21
FWCI
21.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Proteomic Patterns in Biological Fluids: Do They Represent the Future of Cancer Diagnostics? https://app.cochat.ai/papers/10.1373/49.8.1272
The paper
Diamandis, E. P. (2003). Proteomic Patterns in Biological Fluids: Do They Represent the Future of Cancer Diagnostics? Clinical Chemistry. https://doi.org/10.1373/49.8.1272

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.