CoChat

[13C]Nandrolone Excretion in Trained Athletes: Interindividual Variability in Metabolism

Baume, Norbert, Avois, Lidia, Schweizer, Carine, Cardis, Christine, Dvorak, Jiri, Cauderay, Michel, Mangin, Patrice, Saugy, Martial · 2004 · Clinical Chemistry
Cited by 37

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: Nandrolone is one of the most abused anabolic steroids, and its use in doping is increasing, as revealed by numerous positive cases during recent years in various sports. Different authors have reported the possible natural production of nandrolone metabolites in humans, and some of these authors argued that exhaustive exercise could increase nandrolone production in the body or induce dehydration and consequently lead to an increase of nandrolone metabolites in urine. Methods: Volunteers (n = 22) ingested two 25-mg doses of [13C]nandrolone at 24-h intervals and collected urine specimens for 5 days. The labeled nandrolone metabolites 19-norandrosterone and 19-noretiocholanolone were identified and quantified by gas chromatography–mass spectrometry. Results: Interindividual variability was observed in nandrolone excretion patterns and kinetics, as well as for the noretiocholanolone:norandrosterone ratio. The amounts of nandrolone metabolites measured at the excretion peak varied between 1180 and 38 661 μg/L for norandrosterone and 576 and 12 328 μg/L for noretiocholanolone. At the end of the excretion period, the noretiocholanolone:norandrosterone ratio was sometimes >1. The analysis of numerous spot-urine samples allowed the determination of an acceptable correlation between urinary creatinine and specific gravity for placebo- and steroid-treated individuals: y = 0.0052ln(x) + 1.0178 (r2 = 0.8142) and y = 0.0068ln(x) + 1.0172 (r2 = 0.7730), respectively. Conclusions: The excretion kinetics and patterns of labeled nandrolone show interindividual variability. More investigations are currently underway to estimate the influence of exhaustive exercises on excretion of labeled nandrolone metabolites in urine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2003.022848

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Baume, N., Avois, L., Schweizer, C., Cardis, C., Dvorak, J., Cauderay, M., Mangin, P., & Saugy, M.
Venue
Clinical Chemistry
Published
2004-02-01
Volume
50
Issue
2
Pages
355-364
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1994642675
Cited by
37
References
2
FWCI
17.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.