The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Improved HPLC Method for Carbohydrate-deficient Transferrin in Serum
Abstract
Background: There is need for a reference method for transferrin glycoforms in serum to which routine immunologic methods for the alcohol marker carbohydrate-deficient transferrin (CDT) can be traceable. We describe an improved HPLC method for transferrin glycoforms. Methods: Transferrin was iron-saturated by mixing the serum with ferric nitrilotriacetic acid, and lipoproteins were precipitated with dextran sulfate and calcium chloride. Separation of glycoforms was performed on a SOURCE 15Q anion-exchange column using salt gradient elution. Quantification relied on selective absorbance of the iron–transferrin complex at 470 nm. The relative amount of each glycoform was calculated as a percentage of the area under the curve, using baseline integration. Results: The HPLC system provided reproducible separation and quantification of the asialo-, monosialo-, disialo-, trisialo-, tetrasialo-, pentasialo-, and hexasialotransferrin glycoforms. Most importantly, disialo- and trisialotransferrin were almost baseline separated. The intra- and interassay CV for disialotransferrin were <5%. Serum and the pretreated samples were stable for at least 2 days at 22 or 4 °C. Sera from 132 healthy controls contained [mean (SD)] 1.16 (0.25)% disialotransferrin, 4.77 (1.36)% trisialotransferrin, 80.18 (2.01)% tetrasialotransferrin, and 13.88 (1.69)% pentasialo- + hexasialotransferrin. In some cases of a high (>6%) trisialotransferrin, monosialotransferrin was detected at <0.25%. Asialotransferrin was not detected in control sera, but was detected in 57% of chronic heavy drinkers and in 62% of sera with ≥2% disialotransferrin. Conclusions: The HPLC method fulfills the requirements of a preliminary reference method for CDT and should work for any combination of serum transferrin glycoforms. This method could also be useful for confirming positive CDT results by immunoassays in medico-legal cases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SAUNDERS, J. B., AASLAND, O. G., BABOR, T. F., DE LA FUENTE, J. R., & GRANT, M. (1993) · Addiction · doi:10.1111/j.1360-0443.1993.tb02093.x · Cited by 13,597
Cited by
ARADOTTIR, S., ASANOVSKA, G., GJERSS, S., HANSSON, P., & ALLING, C. (2006) · Alcohol and Alcoholism · doi:10.1093/alcalc/agl027 · Cited by 256
Anton, R. F., Latham, P., Voronin, K., Book, S., Hoffman, M., Prisciandaro, J., & Bristol, E. (2020) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2020.0249 · Cited by 186
Walther, L., de Bejczy, A., Löf, E., Hansson, T., Andersson, A., Guterstam, J., Hammarberg, A., Asanovska, G., Franck, J., Söderpalm, B., et al. (2015) · Alcoholism: Clinical and Experimental Research · doi:10.1111/acer.12883 · Cited by 112
Metadata
- Authors
- Helander, A., Husa, A., & Jeppsson, J.-O.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-11-01
- Volume
- 49
- Issue
- 11
- Pages
- 1881-1890
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2119736440
- Cited by
- 170
- References
- 1
- FWCI
- 1.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved HPLC Method for Carbohydrate-deficient Transferrin in Serum. https://app.cochat.ai/papers/10.1373/clinchem.2003.023341
- The paper
- Helander, A., Husa, A., & Jeppsson, J.-O. (2003). Improved HPLC Method for Carbohydrate-deficient Transferrin in Serum. Clinical Chemistry. https://doi.org/10.1373/clinchem.2003.023341
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.