ROC Curves in Clinical Chemistry: Uses, Misuses, and Possible Solutions
Abstract
Background: ROC curves have become the standard for describing and comparing the accuracy of diagnostic tests. Not surprisingly, ROC curves are used often by clinical chemists. Our aims were to observe how the accuracy of clinical laboratory diagnostic tests is assessed, compared, and reported in the literature; to identify common problems with the use of ROC curves; and to offer some possible solutions. Methods: We reviewed every original work using ROC curves and published in Clinical Chemistry in 2001 or 2002. For each article we recorded phase of the research, prospective or retrospective design, sample size, presence/absence of confidence intervals (CIs), nature of the statistical analysis, and major analysis problems. Results: Of 58 articles, 31% were phase I (exploratory), 50% were phase II (challenge), and 19% were phase III (advanced) studies. The studies increased in sample size from phase I to III and showed a progression in the use of prospective designs. Most phase I studies were powered to assess diagnostic tests with ROC areas ≥0.70. Thirty-eight percent of studies failed to include CIs for diagnostic test accuracy or the CIs were constructed inappropriately. Thirty-three percent of studies provided insufficient analysis for comparing diagnostic tests. Other problems included dichotomization of the gold standard scale and inappropriate analysis of the equivalence of two diagnostic tests. Conclusion: We identify available software and make some suggestions for sample size determination, testing for equivalence in diagnostic accuracy, and alternatives to a dichotomous classification of a continuous-scale gold standard. More methodologic research is needed in areas specific to clinical chemistry.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The sample size is sufficient to reject the null hypothesis.
“The sample size is sufficient to reject the null hypothesis24.”
From Integrated algorithm combining plasma biomarkers and cognitive assessments accurately predicts brain β-amyloid pathology (2023) · cites this paper as [24]
Cites
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Protein biomarker discovery and validation: the long and uncertain path to clinical utility
Rifai, N., Gillette, M. A., & Carr, S. A. (2006) · Nature Biotechnology · doi:10.1038/nbt1235 · Cited by 1,867 · see citing works
Understanding diagnostic tests 3: receiver operating characteristic curves
Akobeng, A. K. (2007) · Acta Paediatrica · doi:10.1111/j.1651-2227.2006.00178.x · Cited by 1,882 · see citing works
Screening and comorbidity of clinical levels of fear of cancer recurrence
Simard, S., & Savard, J. (2015) · Journal of Cancer Survivorship · doi:10.1007/s11764-015-0424-4 · Cited by 329 · see citing works
Vali, Y., Lee, J., Boursier, J., Petta, S., Wonders, K., Tiniakos, D., Bedossa, P., Geier, A., Francque, S., Allison, M., et al. (2023) · The Lancet Gastroenterology & Hepatology · doi:10.1016/s2468-1253(23)00017-1 · Cited by 224 · see citing works
Verbakel, J. Y., Steyerberg, E. W., Uno, H., De Cock, B., Wynants, L., Collins, G. S., & Van Calster, B. (2020) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2020.01.028 · Cited by 138 · see citing works
Caveats and pitfalls of ROC analysis in clinical microarray research (and how to avoid them)
Berrar, D., & Flach, P. (2012) · Briefings in Bioinformatics · doi:10.1093/bib/bbr008 · Cited by 136 · see citing works
Accuracy of citrulline, I-FABP and d-lactate in the diagnosis of acute mesenteric ischemia
Nuzzo, A., Guedj, K., Curac, S., Hercend, C., Bendavid, C., Gault, N., Tran-Dinh, A., Ronot, M., Nicoletti, A., Bouhnik, Y., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-98012-w · Cited by 67 · see citing works
Pan, F., Huang, Y., Cai, X., Wang, Y., Guan, Y., Deng, J., Yang, D., Zhu, J., Zhao, Y., Xie, F., et al. (2023) · Communications Medicine · doi:10.1038/s43856-023-00295-9 · Cited by 27 · see citing works
“The sample size is suf fi cient to reject the null hypothesis 24 .”
- Authors
- Obuchowski, N. A., Lieber, M. L., & Wians, F. H.
- Affiliations
- Cleveland Clinic (US)
- The University of Texas Southwestern Medical Center (US)
- Corresponding author
- Obuchowski, Nancy A
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-07-01
- Volume
- 50
- Issue
- 7
- Pages
- 1118-1125
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2112670427
- Cited by
- 358
- References
- 1
- Citations by year
- 2026: 15 · 2025: 21 · 2024: 21 · 2023: 20 · 2022: 18 · 2021: 18 · 2020: 23 · 2019: 19 · 2018: 16 · 2017: 26 · 2016: 22 · 2015: 15 · 2014: 12 · 2013: 13 · 2012: 16
- FWCI
- 3.09
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model (vor)
- Locations
- Clinical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
- Keywords
- ROC curve, diagnostic accuracy, laboratory diagnosis, confidence intervals, sample size determination, equivalence testing, diagnostic test comparison
- MeSH terms
- Chemistry, Clinical, Humans, Periodicals as Topic, ROC Curve
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review