Cited by 358Meta-analysis and systematic reviewsStatistical Methods in EpidemiologyClinical Laboratory Practices and Quality Control

ROC Curves in Clinical Chemistry: Uses, Misuses, and Possible Solutions

Obuchowski, Nancy A, Lieber, Michael L, Wians, Frank H·2004·Clinical Chemistry

Abstract

Background: ROC curves have become the standard for describing and comparing the accuracy of diagnostic tests. Not surprisingly, ROC curves are used often by clinical chemists. Our aims were to observe how the accuracy of clinical laboratory diagnostic tests is assessed, compared, and reported in the literature; to identify common problems with the use of ROC curves; and to offer some possible solutions. Methods: We reviewed every original work using ROC curves and published in Clinical Chemistry in 2001 or 2002. For each article we recorded phase of the research, prospective or retrospective design, sample size, presence/absence of confidence intervals (CIs), nature of the statistical analysis, and major analysis problems. Results: Of 58 articles, 31% were phase I (exploratory), 50% were phase II (challenge), and 19% were phase III (advanced) studies. The studies increased in sample size from phase I to III and showed a progression in the use of prospective designs. Most phase I studies were powered to assess diagnostic tests with ROC areas ≥0.70. Thirty-eight percent of studies failed to include CIs for diagnostic test accuracy or the CIs were constructed inappropriately. Thirty-three percent of studies provided insufficient analysis for comparing diagnostic tests. Other problems included dichotomization of the gold standard scale and inappropriate analysis of the equivalence of two diagnostic tests. Conclusion: We identify available software and make some suggestions for sample size determination, testing for equivalence in diagnostic accuracy, and alternatives to a dichotomous classification of a continuous-scale gold standard. More methodologic research is needed in areas specific to clinical chemistry.

Integrity signals

Registry

Crossref · 10.1373/clinchem.2004.031823

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Obuchowski, N. A., Lieber, M. L., & Wians, F. H.
Affiliations
  • Cleveland Clinic (US)
  • The University of Texas Southwestern Medical Center (US)
Corresponding author
Obuchowski, Nancy A
Venue
Clinical Chemistry
Published
2004-07-01
Volume
50
Issue
7
Pages
1118-1125
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2112670427
Cited by
358
References
1
Citations by year
2026: 15 · 2025: 21 · 2024: 21 · 2023: 20 · 2022: 18 · 2021: 18 · 2020: 23 · 2019: 19 · 2018: 16 · 2017: 26 · 2016: 22 · 2015: 15 · 2014: 12 · 2013: 13 · 2012: 16
FWCI
3.09
Type
journal article
Language
en
Open access
closed
Locations
  • Clinical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
  • Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
Keywords
ROC curve, diagnostic accuracy, laboratory diagnosis, confidence intervals, sample size determination, equivalence testing, diagnostic test comparison
MeSH terms
Chemistry, Clinical, Humans, Periodicals as Topic, ROC Curve

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review