Quantitative, Highly Sensitive Liquid Chromatography–Tandem Mass Spectrometry Method for Detection of Synthetic Corticosteroids
The DOI matches its Crossref record.
Abstract
Background: Measurements of serum or urine concentrations of synthetic glucocorticoids are useful for assessing suspected iatrogenic hypothalamic-pituitary-adrenal axis suppression and Cushing syndrome. We have developed a liquid chromatography–tandem mass spectrometry (LC-MS/MS) assay for the simultaneous quantitative analysis of beclomethasone dipropionate, betamethasone, budesonide, dexamethasone, fludrocortisone, flunisolide, fluorometholone, fluticasone propionate, megestrol acetate, methylprednisolone, prednisolone, prednisone, triamcinolone, and triamcinolone acetonide. Methods: Stable isotopes of cortisol-9,11,12,12-d4 and triamcinolone-d1 acetonide-d6 were added as internal standards to calibrators, controls, and unknown samples. After acetonitrile precipitation, these samples were extracted with methylene chloride, and the extracts were washed and dried. Reconstituted extract (15 μL) was injected on a reversed-phase column and analyzed by LC-MS/MS in positive-ion mode. Assay precision, accuracy, linearity, and sample stability were determined by use of enriched samples. Clinical validation included analysis of 8 serum and 20 urine samples from patients with undetectable cortisol concentrations and analysis of different types of tablets. Results: Functional assay sensitivity was as low as 0.6–1.6 nmol/L for all compounds except for triamcinolone (7.6 nmol/L). Interassay CVs were 3.0–20% for concentrations of 0.6–364 nmol/L for all analytes. Recoveries of all analytes (except triamcinolone in serum) were 82–138% at 19.2–693 nmol/L. All but one of the serum and urine samples from patients who were tested because of suppressed cortisol concentrations contained at least one synthetic steroid. Tablet analysis recovered 75% of the synthetic steroids in suspected drugs. Conclusions: LC-MS/MS allows simultaneous quantitative detection of various synthetic steroids in serum, plasma, urine, and tablets. This provides a valuable tool for evaluating the clinical effects of topical and systemic synthetic corticosteroids.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Maunsell, Z., Wright, D. J., & Rainbow, S. J. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.052936 · Cited by 382
Mass spectrometry and immunoassay: how to measure steroid hormones today and tomorrow
Taylor, A. E., Keevil, B., & Huhtaniemi, I. T. (2015) · European Journal of Endocrinology · doi:10.1530/eje-15-0338 · Cited by 320
Cortisol measurements in Cushing’s syndrome: immunoassay or mass spectrometry?
Casals, G., & Hanzu, F. A. (2020) · Annals of Laboratory Medicine · doi:10.3343/alm.2020.40.4.285 · Cited by 80
Herrero, P., Borrull, F., Pocurull, E., & Marcé, R. M. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.12.054 · Cited by 78
Metadata
- Authors
- Taylor, R. L., Grebe, S. K., & Singh, R. J.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-12-01
- Volume
- 50
- Issue
- 12
- Pages
- 2345-2352
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2170277712
- Cited by
- 114
- References
- 0
- FWCI
- 4.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative, Highly Sensitive Liquid Chromatography–Tandem Mass Spectrometry Method for Detection of Synthetic Corticosteroids. https://app.cochat.ai/papers/10.1373/clinchem.2004.033605
- The paper
- Taylor, R. L., Grebe, S. K., & Singh, R. J. (2004). Quantitative, Highly Sensitive Liquid Chromatography–Tandem Mass Spectrometry Method for Detection of Synthetic Corticosteroids. Clinical Chemistry. https://doi.org/10.1373/clinchem.2004.033605
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.