Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 162

The DOI matches its Crossref record.

Increased Concentrations of Cell-Free Plasma DNA after Exhaustive Exercise

Open access
Atamaniuk, Johanna, Vidotto, Claudia, Tschan, Harald, Bachl, Norbert, Stuhlmeier, Karl M, Müller, Mathias M · 2004 · Clinical Chemistry

Abstract

Physical exercise leads to temporary ischemia in muscles, followed by increased oxygen supply during recovery as a result of reperfusion. It is thought that the sudden influx of oxygen causes a calcium overload in cells, leading to an influx of inflammatory cells into reperfused tissue. This leads to the generation of reactive oxygen radicals and subsequent oxidative damage to DNA, proteins, and lipids. For example, increased oxidant production in the mitochondria of muscles during acute exercise, followed by reoxygenation, was shown to cause cellular damage (1). In addition, exercise may cause transient muscle damage, characterized by muscle soreness, muscle fiber disarrangement, muscle protein release into plasma, an acute immune response, and decreased muscle performance (2). Regional ATP depletion during reperfusion, disruptions in calcium homeostasis, and the presence of oxygen free radicals have all been implicated in the etiology of muscle fiber damage and necrosis. Furthermore, postexercise lymphocytopenia (2) is well documented and attributed to the exit of lymphocytes from the vascular compartment (3). Other studies have reported exercise-induced DNA damage in leukocytes and raised the question of a possible link to apoptosis (3). This effect is thought to be caused by reactive oxygen species, which are released from peripheral monocytes. The aim of this study was to investigate the effects of physical activity, in particular muscle damage and oxidative stress, during and after a half-marathon race and the subsequent recovery period; we also wanted to measure whether oxidative stress attributable to reoxygenation may be a relevant factor in cellular damage. Cell-free plasma DNA concentrations were used as a sensitive tool for quantification of cellular damage and compared with the conventional measurements of myoglobin and uric acid in blood samples. In this study, blood samples from half-marathon runners were taken before the race, immediately after the race, and 2 h after the race. We tested a group of 25 healthy half-marathon runners (12 males and 13 females; age range, 28–56 years). The participants had been training at least 2–8 h per week for 2 years. Blood samples (EDTA plasma and serum) were taken before the race, immediately after the race, and 2 h after the race. These timing intervals were designated as groups 1, 2, and 3. After centrifugation, plasma and serum were separated and immediately frozen at −20 °C until further processing. DNA was isolated from 800 μL of plasma by use of a DNA Isolation reagent set (Roche), according to the described protocol. After isolation, DNA was eluted in 50 μL of elution buffer. Staining with Vistra Green and measurement of cell-free plasma DNA were done on a LightCycler real-time PCR system (Roche) by fluorescent signal detection according to the following protocol: Human placental DNA calibrators (Sigma) were dissolved in Tris-EDTA buffer (1 mmol/L Tris-HCl, 1 mmol/L EDTA, pH 8.0; Sigma) to create a calibration curve ranging from 100 to 5000 pg/μL. Calibrator or sample (5 μL) was pipetted into precooled capillary tubes. Vistra Green nucleic acid gel stain (stock solution in dimethyl sulfoxide; Amersham Bioscience) was diluted 1:1000 in Tris-EDTA buffer, and 5 μL of this dilution was added to each sample or calibrator. After centrifugation (0.8g for 30 s), the emitted fluorescent signals from samples and calibrators were measured in the LightCycler at 530 nm. The cell-free plasma DNA concentrations were reported in pg/μL or recalculated to genome equivalents. Repeated measurements of 500 pg/μL DNA calibrators yielded an analytical imprecision (CV) of 3.1%. For myoglobin measurements, we used an immunofluorescence assay (Brahms; Kryptor Analytical System); the assay imprecision (CV) was 2.8% (mean concentration, 46.1 mg/L). Serum uric acid was measured using an enzymatic colorimetric method (Roche, Germany); the assay imprecision (CV) was 1.2% (mean concentration, 42.6 mg/L). Data were analyzed with STATISTICA for Windows, Ver. 6.0. Descriptive data are reported as the mean (SD). Statistical significance was determined by the Wilcoxon matched-pairs test for nonparametric variables. Statistical significance was defined as P <0.05. The maximum serum uric acid in the resting state was 69 mg/L [mean (SD), 43.6 (10.6) mg/L]. Immediately after the race, uric acid was significantly increased [maximum, 84 mg/L; mean (SD), 53.5 (12.5) mg/L; P <0.0001], and it remained significantly increased 2 h after the race [maximum, 83 mg/L; mean (SD), 54.7 (12.4) mg/L; P for comparison with baseline <0.0001]. Before the race, the mean (SD) serum myoglobin was 44.3 (12.59) μg/L (maximum, 87 μg/L). Immediately after the race, serum myoglobin was significantly increased [maximum, 2503 μg/L; mean (SD), 533.48 (540.45) μg/L; P <0.0001]. After a 2-h recovery period, mean (SD) serum myoglobin was 631.08 (500.86) μg/L, and the maximum was 1984 μg/L (P <0.001). In the resting state

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2004.034553

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Atamaniuk, J., Vidotto, C., Tschan, H., Bachl, N., Stuhlmeier, K. M., & Müller, M. M.
Venue
Clinical Chemistry
Published
2004-09-01
Volume
50
Issue
9
Pages
1668-1670
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2123582374
Cited by
162
References
0
FWCI
4.09
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.