Noninvasive Measurement of Glucose by Metabolic Heat Conformation Method
The DOI matches its Crossref record.
Abstract
Background: We developed a method, called the metabolic heat conformation (MHC) method, for the noninvasive measurement of blood glucose. The MHC method involves the measurement of physiologic indices related to metabolic heat generation and local oxygen supply, which correspond to the glucose concentration in the local blood supply. Methods: We used noninvasive thermal and optical sensors on the fingertip of an individual to measure thermal generation, blood flow rate, hemoglobin (Hb) concentration, and oxyhemoglobin concentration. The calibration model incorporates mathematical procedures to convert signals from the sensor pickup to final glucose concentrations. The mathematical procedures are multivariate statistical analyses, involving values from sensor signals, polynomials from various values, regression analyses of individual patients, and cluster analyses of patient groups. The glucose value is calculated for each patient measurement, applying one of the clusters by discriminant analysis. Results: Regression analysis was performed to compare the noninvasive method with the hexokinase method, using 127 data points (109 data points from diabetic patients, 18 data points from nondiabetic patients) with glucose concentrations ranging from 3.0 to 22.5 mmol/L (54–405 mg/dL). The correlation coefficient (r) was 0.91. Reproducibility was measured for healthy fasting persons; the CV was 6% at 5.56 mmol/L (100 mg/dL). Conclusions: These data provide preliminary evidence that the MHC method can be used to estimate blood glucose concentrations noninvasively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent advances in electrochemical glucose biosensors: a review
Chen, C., Xie, Q., Yang, D., Xiao, H., Fu, Y., Tan, Y., & Yao, S. (2013) · RSC Advances · doi:10.1039/c2ra22351a · Cited by 807
Villena Gonzales, W., Mobashsher, A., & Abbosh, A. (2019) · Sensors · doi:10.3390/s19040800 · Cited by 772
Non-invasive glucose monitoring technology in diabetes management: A review
Vashist, S. K. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.043 · Cited by 575
Skin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring
Chen, Y., Lu, S., Zhang, S., Li, Y., Qu, Z., Chen, Y., Lu, B., Wang, X., & Feng, X. (2017) · Science Advances · doi:10.1126/sciadv.1701629 · Cited by 467
Current development in non-invasive glucose monitoring
Ferrante do Amaral, C. E., & Wolf, B. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.06.003 · Cited by 269
Metadata
- Authors
- Cho, O. K., Kim, Y. O., Mitsumaki, H., & Kuwa, K.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-10-01
- Volume
- 50
- Issue
- 10
- Pages
- 1894-1898
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2163850005
- Cited by
- 104
- References
- 0
- FWCI
- 1.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive Measurement of Glucose by Metabolic Heat Conformation Method. https://app.cochat.ai/papers/10.1373/clinchem.2004.036954
- The paper
- Cho, O. K., Kim, Y. O., Mitsumaki, H., & Kuwa, K. (2004). Noninvasive Measurement of Glucose by Metabolic Heat Conformation Method. Clinical Chemistry. https://doi.org/10.1373/clinchem.2004.036954
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.