Cited by 269Diabetes Management and ResearchSpectroscopy Techniques in Biomedical and Chemical ResearchNon-Invasive Vital Sign Monitoring

Current development in non-invasive glucose monitoring

Ferrante do Amaral, Carlos Eduardo, Wolf, Benhard·2008·Medical Engineering & Physics

Abstract

Painless control of blood glycemic levels could improve life quality of diabetes patients, enabling a better regulation of hyper- and hypoglycaemia episodes and thereby avoiding physiological complications. Although research groups have been trying for decades to separate non-invasive glucose information from interference compounds, none of the available commercial devices offers enough precision to replace lancet approaches. Many reviews have already been published on this topic, but the great amount of information available and the fast development of technologies require a continuous update in the research status. Besides the description of current in-vivo methods and the analysis of devices available commercially, one also explains treatment algorithms useful for multivariate analysis.

Integrity signals

Registry

Crossref · 10.1016/j.medengphy.2007.06.003

Cites

71 of 71 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Almost all invasive sensing devices have infection risks, discomfort, and analytical response problems related to the foreign body response.

    “Almost all invasive sensing devices are characterized by infection risks, discomfort, and analytical response issues related to the foreign body response (FBR).29–30”
  • Sweating, often linked to hypoglycemia, alters glucose extraction rate and causes erroneous iontophoretic readings.

    “Additionally, sweating, often associated with hypoglycemia, affects the rate of extraction of glucose and therefore causes erroneous results when readings must be most accurate.29–30”

Cites

Flagged first, then by citations

2 of the 73 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Ferrante do Amaral, C. E., & Wolf, B.
Affiliations
Technical University of Munich (DE)
Venue
Medical Engineering & Physics
Published
2007-10-18
Volume
30
Issue
5
Pages
541-549
ISSN
  • 1350-4533 (ISSN-L)
  • 1873-4030
OpenAlex
W1975209404
Cited by
269
References
73
Citations by year
2026: 6 · 2025: 9 · 2024: 11 · 2023: 16 · 2022: 18 · 2021: 19 · 2020: 16 · 2019: 19 · 2018: 18 · 2017: 25 · 2016: 20 · 2015: 17 · 2014: 12 · 2013: 14 · 2012: 17
FWCI
0.62
Type
journal article
Language
en
Open access
closed
Locations
  • Medical Engineering & Physics (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Deutscher Akademischer Austauschdienst
  • Heinz Nixdorf Stiftung
  • U.S. Food and Drug Administration
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
non-invasive glucose monitoring, diabetes mellitus, glycemic control, hypoglycemia, hyperglycemia, multivariate analysis, treatment algorithm
MeSH terms
Blood Glucose, Humans, Monitoring, Physiologic, Physics, Spectrum Analysis, Physical Phenomena

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review