Performance Characteristics of Six Third-Generation Assays for Thyroid-Stimulating Hormone
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: Thyroid-stimulating hormone (TSH) is used to detect primary hypo- and hyperthyroidism. Current guidelines for TSH assays recommend a functional sensitivity of ≤0.02 mIU/L. The protocol for determining the functional sensitivity of TSH assays specifies analyses of serum samples with two reagent lots over a 6- to 8-week period. Methods: We determined the functional sensitivities of the Access 2, ADVIA Centaur, ARCHITECT i2000, E170, IMMULITE 2000, and Vitros ECi automated methods, using seven serum pools and two reagent lots for each method. Results: The observed functional sensitivities were as follows: Access 2, <0.020 mIU/L; ADVIA Centaur, 0.039 mIU/L; ARCHITECT i2000, <0.005 mIU/L; Elecsys E170, 0.011 mIU/L; IMMULITE 2000, 0.014 mIU/L; Vitros ECi, 0.004 mIU/L. However, there were large differences between some method means for the seven serum pools. For the pool with the lowest TSH concentration, mean results were as follows: Access 2, 0.0203 mIU/L; ADVIA Centaur, 0.0085 mIU/L; ARCHITECT i2000, 0.0049 mIU/L; E170, 0.0098 mIU/L; IMMULITE 2000, 0.0077 mIU/L; Vitros ECi, 0.0014 mIU/L. Method-comparison studies using samples with TSH concentrations >0.2 mIU/L also showed method differences. The ARCHITECT i2000 method was the most precise at low TSH concentrations. Conclusions: TSH methods do not provide comparable results for serum pools with TSH concentrations <0.2 mIU/L or for patient results across the analytic measurement range. Further investigation into the cause of these differences and additional harmonization efforts are required.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laboratory Support for the Diagnosis and Monitoring of Thyroid Disease
(2003) · Thyroid · doi:10.1089/105072503321086962 · Cited by 1,212
Cited by
The fundamental flaws of immunoassays and potential solutions using tandem mass spectrometry
Hoofnagle, A. N., & Wener, M. H. (2009) · Journal of Immunological Methods · doi:10.1016/j.jim.2009.06.003 · Cited by 561
Microfluidic Chips for Point‐of‐Care Immunodiagnostics
Gervais, L., de Rooij, N., & Delamarche, E. (2011) · Advanced Materials · doi:10.1002/adma.201100464 · Cited by 491
Spencer, C. A., Hollowell, J. G., Kazarosyan, M., & Braverman, L. E. (2007) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2007-0287 · Cited by 227
“Although current TSH immunometric assays are all standardized against the same International Reference Preparation, significant variability may reflect differences in monoclonal antibody specificity for different circulating TSH isoforms (5).”
BackgroundIs there a need to redefine the upper normal limit of TSH?
Brabant, G., Beck-Peccoz, P., Jarzab, B., Laurberg, P., Orgiazzi, J., Szabolcs, I., Weetman, A. P., & Wiersinga, W. M. (2006) · European Journal of Endocrinology · doi:10.1530/eje.1.02136 · Cited by 211
Kapelari, K., Kirchlechner, C., Högler, W., Schweitzer, K., Virgolini, I., & Moncayo, R. (2008) · BMC Endocrine Disorders · doi:10.1186/1472-6823-8-15 · Cited by 203
Metadata
- Authors
- Rawlins, M. L., & Roberts, W. L.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-12-01
- Volume
- 50
- Issue
- 12
- Pages
- 2338-2344
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2129680415
- Cited by
- 98
- References
- 1
- FWCI
- 2.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance Characteristics of Six Third-Generation Assays for Thyroid-Stimulating Hormone. https://app.cochat.ai/papers/10.1373/clinchem.2004.039156
- The paper
- Rawlins, M. L., & Roberts, W. L. (2004). Performance Characteristics of Six Third-Generation Assays for Thyroid-Stimulating Hormone. Clinical Chemistry. https://doi.org/10.1373/clinchem.2004.039156
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.