CoChat

Validation by a Mass Spectrometric Reference Method of Use of Boronate Affinity Chromatography to Measure Glycohemoglobin in the Presence of Hemoglobin S and C Traits

Little, Randie R, Vesper, Hubert, Rohlfing, Curt L, Ospina, Maria, Safar-Pour, Sekineh, Roberts, William L · 2005 · Clinical Chemistry
Cited by 56

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Glycohemoglobin (GHB) is routinely used both as an index of mean glycemia and as a measure of risk for the development and progression of diabetes complications (1)(2). Because the prevalence of diabetes is higher for non-Hispanic blacks than in non-Hispanic whites (3) and at least 10% of black Americans have either hemoglobin S (HbS) or HbC trait (4), it is probable that at least 150 000 Americans with diabetes have HbS or HbC trait. Previous studies have shown that some GHB methods yield inaccurate results with samples heterozygous for HbS or HbC (5)(6)(7)(8)(9). Many of these interference studies have used boronate affinity chromatography as a reference method based on the assumption that this method should not be influenced by the presence of Hb variants (10). Because measurement of GHB by boronate affinity chromatography is based on the structure of the glycated component (cis-diol component of GHB), rather than differences in charge, it has been assumed that glycated HbS and/or HbC are included in the glycated fraction and that GHB results obtained with boronate affinity methods, when these traits are present, are therefore equivalent to those obtained in homozygous HbA samples. However, there is no conclusive proof of this noninterference. Furthermore, recent comparisons between non-HPLC boronate affinity-based GHB methods and the CLC330 method have shown that these methods gave higher results for samples with HbC trait than the CLC330 (7)(8). Here we compare the CLC330 boronate affinity HPLC method (Primus Corporation) with the IFCC Mass Spectrometry (MS) Reference Method for HbA1c that is specific for HbA1c (11). The first step in the procedure for the IFCC reference method (specifically measuring the β-N-terminal hexapeptide) is the cleavage of hemoglobin with the proteolytic enzyme endoproteinase Glu-C at position 6 from the N-terminal end of the β-chain. Because both HbS and HbC contain substitutions at this position on the Hb chain, there should be no hexapeptide formed from this enzymatic digestion of either of these hemoglobins. As expected, this reference method has previously been shown to produce no signal at the position of the N-terminal hexapeptide when purified HbS and HbC were analyzed (11). Therefore, only HbA hexapeptide glycation is measured with this method, and the presence of these traits does not interfere with measurement of HbA1c. Assuming no difference in glycation rates for HbS and HbC vs HbA (12), the relationship between the IFCC MS method (which measures HbA1c in relation to total HbA) and the CLC330 affinity HPLC (which measures total GHB in relation to total Hb) method should therefore be the same regardless of whether the samples contain HbAS, HbAC, or HbAA. To confirm this hypothesis, we collected and analyzed 63 samples containing HbAA (n = 20), HbAS (n = 23), or HbAC (n = 20) by both the CLC330 HPLC and IFCC MS methods. This study was approved by the Institutional Review Board of the University of Utah Health Sciences Center. Statistical analyses were performed with SAS and Excel. IFCC MS results were converted to the currently reported National Glycohemoglobin Standardization Program/Diabetes Control and Complications Trial (NGSP/DCCT) equivalent HbA1c number scale (13) by use of a previously developed master equation (14) so that absolute differences in results between methods could be compared. Results from the CLC330 HPLC method were expressed as NGSP HbA1c equivalents. The relationships between the two methods for samples containing each of these traits were determined by linear regression analysis (Fig. 11 ). To determine whether the presence of HbS or HbC trait caused a statistically significant difference in results (vs HbAA), we performed an overall test of coincidence of least-squares linear regression lines (SAS Institute). As in previous studies, HbA1c concentrations of 6% (the upper limit of normal) and 9% were also used as clinical evaluation limits (7)(8)(9). The results show that the relationships between the two methods when GHB is measured in samples containing HbAS or HbAC are not statistically significantly different from the relationship in HbAA (P = 0.59 and 0.71 for HbS and HbC, respectively). After we subtracted the differences between the two methods in HbAA samples, the average differences between MS and boronate affinity were −0.03% and −0.15% GHB at 6% GHB and 0.23% and 0.04% GHB at 9% GHB for HbAS and HbAC, respectively. We conclude that CLC330 boronate affinity GHB results for samples heterozygous for HbS and HbC are comparable to those of the IFCC reference method, which has been shown to have no interference. These data support the contention that the CLC330 boronate affinity HPLC assay is not affected by the presence of HbS or HbC trait and is therefore an appropriate comparative method for the study of HbS and HbC interference with GHB methods. Relationship between HbA1c measured by the IFCC MS and CLC330 HPLC methods. Results are

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2004.043141

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 56

Metadata

Authors
Little, R. R., Vesper, H., Rohlfing, C. L., Ospina, M., Safar-Pour, S., & Roberts, W. L.
Venue
Clinical Chemistry
Published
2005-01-01
Volume
51
Issue
1
Pages
264-265
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2128212703
Cited by
56
References
6
FWCI
1.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.