Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 265

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Diagnostic Performance of Quantitative κ and λ Free Light Chain Assays in Clinical Practice

Katzmann, Jerry A, Abraham, Roshini S, Dispenzieri, Angela, Lust, John A, Kyle, Robert A·2005·Clinical Chemistry

Abstract

Background: The quantitative assay for free light chains (FLCs) is a recently introduced commercial test reported to be sensitive and specific for detecting FLC diseases such as primary systemic amyloidosis (AL), light chain deposition disease (LCDD), nonsecretory multiple myeloma (NSMM), and light chain multiple myeloma. We evaluated its diagnostic performance in clinical practice. Methods: All FLC clinical test results generated in 2003 were abstracted from the Laboratory Information System. Diagnoses were obtained from the Dysproteinemia database and the patient medical history. Results: In 2003, we received samples for FLC assays from 1020 Mayo Clinic patients. The majority of these patients (88%) had bone marrow-derived monoclonal plasma cell disorders (PCDs). The 121 patients who did not have monoclonal gammopathy all had FLC κ/λ ratios within the range of values obtained for a reference population in our laboratory. Among the patients with monoclonal gammopathies were patients with multiple myeloma (330), AL (269), monoclonal gammopathy of undetermined significance (114), smoldering multiple myeloma (72), plasmacytoma (22), NSMM (20), macroglobulinemia (9), LCDD (7), and a variety of other PCDs. Among the 110 AL patients who had not been previously treated and who had a FLC assay performed within 120 days of diagnosis, the FLC κ/λ ratio was positive in 91% compared with 69% for serum immunofixation electrophoresis (IFE) and 83% for urine IFE. The combination of serum IFE and serum FLC assay detected an abnormal result in 99% (109 of 110) of patients with AL. Conclusion: The performance of the FLC assay in this analysis of clinical laboratory data is consistent with results from published retrospective validation studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2004.046870

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 265

Metadata

Authors
Katzmann, J. A., Abraham, R. S., Dispenzieri, A., Lust, J. A., & Kyle, R. A.
Venue
Clinical Chemistry
Published
2005-05-01
Volume
51
Issue
5
Pages
878-881
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2047565570
Cited by
265
References
8
FWCI
10.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic Performance of Quantitative κ and λ Free Light Chain Assays in Clinical Practice. https://app.cochat.ai/papers/10.1373/clinchem.2004.046870
The paper
Katzmann, J. A., Abraham, R. S., Dispenzieri, A., Lust, J. A., & Kyle, R. A. (2005). Diagnostic Performance of Quantitative κ and λ Free Light Chain Assays in Clinical Practice. Clinical Chemistry. https://doi.org/10.1373/clinchem.2004.046870

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.