CoChat

Increased Osteoclast Activity in the Presence of Increased Homocysteine Concentrations

Herrmann, Markus, Widmann, Thomas, Colaianni, Graziana, Colucci, Silvia, Zallone, Alberta, Herrmann, Wolfgang · 2005 · Clinical Chemistry
Cited by 126

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: Increased plasma homocysteine (HCY) may be an independent risk factor for osteoporotic fractures and therefore may also adversely affect bone metabolism. We analyzed the effect of HCY on human osteoclast (OC) activity. Methods: We cultured peripheral blood mononuclear cells from 17 healthy male donors [median (SD) age, 30 (5) years] for 20 days with 25 μg/L macrophage-colony-stimulating factor (days 0–11), 20 μg/L receptor-activator of nuclear factor-κB ligand (days 6–20), and 4 different concentrations of HCY (0, 10, 50, and 100 μmol/L; days 0–20). For control purposes, cysteine and glutathione were tested in equimolar concentrations. OCs were identified as large, multinucleated cells with tartrate-resistant acid phosphatase (TRAP) activity and surface vitronectin receptors. We quantified OC activity by measuring TRAP activity. We analyzed cathepsin K (CP-K) activity in 9 donor samples and estimated the dentine-resorbing activity on standard dentine slices in 3 samples. Results: After 20 days of culture, most cells were fully differentiated OCs. TRAP activity increased with increasing HCY concentrations (P <0.001). HCY concentrations of 10, 50, and 100 μmol/L stimulated TRAP activity by 20%, 15%, and 42%. Additionally, HCY stimulated CP-K activity (P = 0.005): in the presence of 100 μmol/L HCY, CP-K activity was ∼38% higher than in controls (P = 0.002). Bone-resorbing activity was significantly increased in cultures with 50 and 100 μmol/L HCY. Cysteine and glutathione significantly decreased TRAP and CP-K activity. Conclusions: Increased HCY concentrations specifically stimulate OC activity in vitro, suggesting a mechanistic role of HCY for bone resorption. Future studies clarifying the mechanistic role of increased HCY concentrations in osteoporosis could have interesting therapeutic implications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2005.053363

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

1 retracted

Cited by

See all 126

Metadata

Authors
Herrmann, M., Widmann, T., Colaianni, G., Colucci, S., Zallone, A., & Herrmann, W.
Venue
Clinical Chemistry
Published
2005-12-01
Volume
51
Issue
12
Pages
2348-2353
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2104090398
Cited by
126
References
3
FWCI
3.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.