Automated Assay for the Determination of Methylmalonic Acid, Total Homocysteine, and Related Amino Acids in Human Serum or Plasma by Means of Methylchloroformate Derivatization and Gas Chromatography–Mass Spectrometry
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: The combined measurement of methylmalonic acid (MMA) and total homocysteine (tHcy) in serum or plasma is useful in diagnosing and distinguishing between cobalamin and folate deficiencies. We developed and validated an isotope-dilution gas chromatography–mass spectrometry (GC-MS) method with automated sample workup for the determination of MMA, tHcy, and the related amino acids Met, total cysteine (tCys), Ser, and Gly in serum or plasma. Methods: Serum or plasma samples (100 μL) were treated with a reductant (dithioerythritol), deproteinized with ethanol, and derivatized and extracted in a single step by the addition of methylchloroformate and toluene. All liquid handling was performed in 96-well (1 mL) microtiter plates by a robotic workstation. The N(S)-methoxycarbonyl ethyl ester derivatives were analyzed by GC-MS in the selected-ion monitoring mode. Results: Detection limits (signal-to-noise ratio, 5:1) were between 0.03 μmol/L (MMA) and 10 μmol/L (Ser, tCys). The assay was linear to 100 μmol/L for MMA and tHcy and to 1000 μmol/L for Met, tCys, Ser, and Gly. The within-day CVs ranged from 0.7% to 3.6% (n = 20), and the between-day CVs from 2.1% to 8.1% (n = 20). The recovery was between 79% and 99% for the different analytes. Conclusion: This assay combines a simple and automated sample preparation with selective and sensitive GC-MS analysis and is well suited for the combined measurement of MMA, tHcy, and the related amino acids.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Altamura, C., Maes, M., Dai, J., & Meltzer, H. Y. (1995) · European Neuropsychopharmacology · doi:10.1016/0924-977x(95)00033-l · Cited by 193
Cited by
Aggregation-Induced Emission: Together We Shine, United We Soar!
Mei, J., Leung, N. L. C., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00263 · Cited by 8,270
Homocysteine Lowering and Cardiovascular Events after Acute Myocardial Infarction
Bønaa, K. H., Njølstad, I., Ueland, P. M., Schirmer, H., Tverdal, A., Steigen, T., Wang, H., Nordrehaug, J. E., Arnesen, E., & Rasmussen, K. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa055227 · Cited by 1,442
Self-citationBiomarkers of Nutrition for Development—Folate Review
Bailey, L. B., Stover, P. J., McNulty, H., Fenech, M. F., Gregory, J. F., Mills, J. L., Pfeiffer, C. M., Fazili, Z., Zhang, M., Ueland, P. M., et al. (2015) · The Journal of Nutrition · doi:10.3945/jn.114.206599 · Cited by 1,136
Self-citationFolic Acid for the Prevention of Colorectal Adenomas: A Randomized Clinical Trial
Cole, B. F., Baron, J. A., Sandler, R. S., Haile, R. W., Ahnen, D. J., Bresalier, R. S., McKeown-Eyssen, G., Summers, R. W., Rothstein, R. I., Burke, C. A., et al. (2007) · JAMA · doi:10.1001/jama.297.21.2351 · Cited by 929
Self-citationEbbing, M., Bleie, Ø., Ueland, P. M., Nordrehaug, J. E., Nilsen, D. W., Vollset, S. E., Refsum, H., Ringdal Pedersen, E. K., & Nygård, O. (2008) · JAMA · doi:10.1001/jama.300.7.795 · Cited by 411
Self-citationFluge, Ø., Mella, O., Bruland, O., Risa, K., Dyrstad, S. E., Alme, K., Rekeland, I. G., Sapkota, D., Røsland, G. V., Fosså, A., et al. (2016) · JCI Insight · doi:10.1172/jci.insight.89376 · Cited by 209
“The 20 standard amino acids were analyzed by robotic workstations using gas chromatography–tandem mass spectrometry (54, 55), with within and between day CVs of 2%–5%.”
MethodSelf-citationFredriksen, Å., Meyer, K., Ueland, P. M., Vollset, S. E., Grotmol, T., & Schneede, J. (2007) · Human Mutation · doi:10.1002/humu.20522 · Cited by 188
“Folate and vitamin B12 (cobalamin) were determined in serum, and tHcy, MMA, vitamin B2 (riboflavin), vitamin B6 (pyridoxal 5 0phosphate, PLP), choline, betaine, dimethylglycine (DMG), cystathionine, cysteine, methionine, and creatinine were determined in plasma, using published methods [Holm et al., 2003; Midttun et a…”
Self-citationEussen, S. J. P. M., de Groot, C. P. G. M., Joosten, L. W., Bloo, R. J., Clarke, R., Ueland, P. M., Schneede, J., Blom, H. J., Hoefnagels, W. H. L., & van Staveren, W. A. (2006) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/84.1.361 · Cited by 188
“Plasma tHcy concentrations were measured by using a method based on methylchloroformate derivatization and gas chromatography–mass spectrometry (33), and plasma holoTC was measured by using the AXIS-Shield radioimmunoassay method (34).”
MethodSelf-citationEussen, S. J., de Groot, L. C., Joosten, L. W., Bloo, R. J., Clarke, R., Ueland, P. M., Schneede, J., Blom, H. J., Hoefnagels, W. H., & van Staveren, W. A. (2006) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/84.2.361 · Cited by 179
Self-citationKvestad, I., Hysing, M., Shrestha, M., Ulak, M., Thorne-Lyman, A. L., Henjum, S., Ueland, P. M., Midttun, Ø., Fawzi, W., Chandyo, R. K., et al. (2017) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.116.144931 · Cited by 92
Self-citationBjørke-Monsen, A.-L., Torsvik, I., Sætran, H., Markestad, T., & Ueland, P. M. (2008) · PEDIATRICS · doi:10.1542/peds.2007-2716 · Cited by 66
Self-citationCatena, A., Muñoz-Machicao, J. A., Torres-Espínola, F. J., Martínez-Zaldívar, C., Diaz-Piedra, C., Gil, A., Haile, G., Györei, E., Molloy, A. M., Decsi, T., et al. (2016) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.115.109108 · Cited by 46
Components of one-carbon metabolism other than folate and colorectal cancer risk
Myte, R., Gylling, B., Schneede, J., Ueland, P. M., Häggström, J., Hultdin, J., Hallmans, G., Johansson, I., Palmqvist, R., & Van Guelpen, B. (2016) · Epidemiology · doi:10.1097/ede.0000000000000529 · Cited by 29
Self-citation
Metadata
- Authors
- Windelberg, A., Årseth, O., Kvalheim, G., & Ueland, P. M.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-11-01
- Volume
- 51
- Issue
- 11
- Pages
- 2103-2109
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2149340056
- Cited by
- 154
- References
- 1
- FWCI
- 4.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.