CoChat

Effect of Sample Collection Tubes on Cerebrospinal Fluid Concentrations of Tau Proteins and Amyloid β Peptides

Lewczuk, Piotr, Beck, Georg, Esselmann, Hermann, Bruckmoser, Ralf, Zimmermann, Rüdiger, Fiszer, Magdalena, Bibl, Mirko, Maler, Juan Manuel, Kornhuber, Johannes, Wiltfang, Jens · 2006 · Clinical Chemistry
Cited by 143

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Tau protein and its phosphorylated forms, and amyloid β peptides ending at amino acid 42 (Aβ42) are used as cerebrospinal fluid (CSF) biomarkers of Alzheimer disease (AD) (1)(2)(3)(4)(5)(6)(7)(8). Because preanalytical factors may affect results (4)(9)(10), we measured these biomarkers in CSF samples in collection tubes made of different materials. After approval by the Ethics Committee of the University of Erlangen-Nuremberg, patients and/or their closest relatives gave written informed consent. CSF was obtained from patients (n = 20; mean age, 66 years; 9 women and 11 men) with various neuropsychiatric diseases, including dementias (n = 9), mild cognitive impairment (n = 8), recurrent depression (n = 1), bipolar disorder (n = 1), and emotionally unstable personality (n = 1). We included only CSF samples showing no or only minor contamination with erythrocytes (<150/μL), no intrathecal humoral or cellular immune response, and normal or only slightly disturbed blood–CSF barrier as measured by albumin quotient. After collecting 4–5 mL of CSF for routine analyses, we transferred four 0.5-mL fractions directly into 4 test tubes in this order: (a), polycarbonate (PC; Sarstedt; cat. no. 60.9922.936); (b), a copolymer of polystyrene and acrylonitrile [modified polystyrene (PX); Sarstedt; cat. no. 60.9924.952]; (c), polystyrene (PS; Sarstedt; cat. no. 62.553.542PS); and (d), polypropylene (PP; Sarstedt; cat. no. 62.554.502PP). Fractions were centrifuged simultaneously (1600g for 15 min at room temperature) immediately after the spinal puncture and were frozen at −80 °C within 30–40 min. The material was never thawed and refrozen.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2005.058776

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 143

Metadata

Authors
Lewczuk, P., Beck, G., Esselmann, H., Bruckmoser, R., Zimmermann, R., Fiszer, M., Bibl, M., Maler, J. M., Kornhuber, J., & Wiltfang, J.
Venue
Clinical Chemistry
Published
2006-02-01
Volume
52
Issue
2
Pages
332-334
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1983874275
Cited by
143
References
4
FWCI
4.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.