The DOI matches its Crossref record.
Why Commutability Matters
Abstract
A fundamental goal of laboratory medicine is that results for patients’ samples will be comparable independent of the medical laboratory that produced the results. Routine measurement procedures of acceptable analytical specificity that have calibration traceable to the same higher-order reference material or reference measurement procedure should produce numerical values for clinical samples that are comparable irrespective of time, place, or laboratory generating the result. The term “commutability” was first used to describe the ability of a reference or control material to have interassay properties comparable to the properties demonstrated by authentic clinical samples when measured by more than one analytical method (1)(2)(3). More recent metrologic documents expand the concept; they describe commutability as the equivalence of the mathematical relationships between the results of different measurement procedures for a reference material and for representative samples from healthy and diseased individuals (4)(5). A reference material is typically used to establish or verify the traceability of a measurement procedure to a value assigned to the material that represents the best estimate of the correct, or true, value. Concentration or activity values are assigned to reference materials by higher-order measurement procedures, when possible, or alternatively by a consensus process when reference measurement procedures are not available. When a reference material is intended to be measured by a routine clinical method, commutability must be validated among all of the methods that will use the material, including the reference measurement procedure when appropriate. Ultimately, a reference material is used to ensure that the results for clinical samples assayed by routine measurement procedures have numerical values that are equivalent, irrespective of the clinical routine method used for the measurement. When commutability of a reference material is not established, the results from routine methods cannot be legitimately compared with the assigned value to determine whether a bias exists in calibration, nor can the reference material be used as a calibrator. Observed biases are attributable either to the noncommutability of the reference material or to the differing specificities and calibration procedures of the methods examined. Without an assessment of the commutability of the material used in the method comparison, it is not possible to determine whether any observed biases are artifacts of the comparison, as a result of an inadequate material, or are genuine biases among the methods examined. Noncommutability of a reference material can be caused by a matrix alteration or by a nonnative analyte. A matrix effect or a matrix bias can be caused by differences in sample matrix between the reference material and the native clinical samples. The sample matrix includes all components of a material system except the analyte itself (4). A matrix effect is defined as the influence of a property of the sample, independent of the presence of the analyte, on the measurement and thereby on the value of the measurable quantity (4). Nonnative forms of the analyte, such as enzymes of nonhuman origin, conjugates with nonphysiologic molecules (e.g., ditaurobilirubin), or protein complexes modified during isolation from human sources, can produce a different measurement signal than expected for native forms of the analyte. Biases attributable to matrix effects and nonnative analytes have been reported for many reference and control materials used in laboratory medicine (1)(2)(3)(6)(7)(8)(9). Lack of specificity is a potential limitation for any analytical procedure, but it is of particular importance for immunoassays, in which antibody specificities (e.g., for various epitopes of an analyte) can differ among measurement procedures (9)(10). Nonspecificity for the analyte found in native clinical samples is a method limitation distinct from noncommutability influences, but it can be a confounding factor when the commutability of a reference material is being validated among methods. Calibration of measurement procedures with reference materials that are not commutable can cause poorer, rather than improved, agreement of results among methods for native clinical samples. Such a degradation in performance can occur when the observed bias is actually attributable to noncommutability of the material, rather than being a true calibration bias. Consequently, the traceability of the calibration to the reference system is not valid, and the net impact on results for native clinical samples cannot be predicted. In the February issue of this journal, Bunk and Welch (11) reported the characterization of a new certified reference material for human cardiac troponin I. The report provided characterization of the subunit composition of the troponin complex used in the material and a mass value assignment for the troponin I component th
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Clemmons, D. R. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.150631 · Cited by 353
Proficiency Testing/External Quality Assessment: Current Challenges and Future Directions
Miller, W. G., Jones, G. R., Horowitz, G. L., & Weykamp, C. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2011.168641 · Cited by 341
Self-citationMiller, W. G., Myers, G. L., Ashwood, E. R., Killeen, A. A., Wang, E., Ehlers, G. W., Hassemer, D., Lo, S. F., Seccombe, D., Siekmann, L., et al. (2008) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2008-132-838-sotait · Cited by 87
Self-citationTheodorsson, E., Magnusson, B., & Leito, I. (2014) · Bioanalysis · doi:10.4155/bio.14.249 · Cited by 73
Laboratory medicine best practice guideline: vitamins a, e and the carotenoids in blood.
(2014) · PubMed Central · Cited by 44
Metadata
- Authors
- Miller, W. G., Myers, G. L., & Rej, R.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-04-01
- Volume
- 52
- Issue
- 4
- Pages
- 553-554
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2124851063
- Cited by
- 178
- References
- 0
- FWCI
- 6.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Why Commutability Matters. https://app.cochat.ai/papers/10.1373/clinchem.2005.063511
- The paper
- Miller, W. G., Myers, G. L., & Rej, R. (2006). Why Commutability Matters. Clinical Chemistry. https://doi.org/10.1373/clinchem.2005.063511
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.