HPLC Method for 25-Hydroxyvitamin D Measurement: Comparison with Contemporary Assays

Lensmeyer, Gary L, Wiebe, Donald A, Binkley, Neil, Drezner, Marc K·2006·Clinical Chemistry

Abstract

Background: The concentration of 25-hydroxyvitamin D [25(OH)D] in serum has been designated the functional indicator of vitamin D (VitD) nutritional status. Unfortunately, variability among 25(OH)D assays limits clinician ability to monitor VitD status, supplementation, and toxicity. Methods: We developed an HPLC method that selectively measures 25-hydroxyvitamin D2 [25(OH)D2] and D3 [25(OH)D3] and compared this assay with a liquid chromatography–tandem mass spectrometry (LC-MS/MS) method, a competitive protein-binding assay (CPBA) on the Nichols Advantage™ platform, and an RIA from Diasorin. Results: For the new HPLC assay, between-run CVs were 2.6%–4.9% for 25(OH)D3 and 3.2%–13% for 25(OH)D2; recoveries were 95%–102%; and the assay was linear from 5 μg/L to at least 200 μg/L. Comparison data were as follows: for HPLC vs LC-MS/MS, y = 1.01x − 4.82 μg/L (Sy|x = 4.93 μg/L; r = 0.996) for 25(OH)D3, and y = 0.902x − 0.566 μg/L (Sy|x = 2.56 μg/L; r = 0.9965 for 25(OH)D2; for HPLC vs Diasorin RIA, y = 0.709x − 5.86 μg/L (Sy|x = 7.35 μg/L; r = 0.7509); and for HPLC vs Nichols Advantage CPBA, y = 1.00x − 3.60 μg/L (Sy|x = 32.7 μg/L; r = 0.6823). Conclusions: The new HPLC method is reliable, robust, and has advantages compared with the Nichols Advantage CPBA and the Diasorin RIA. The Nichols Advantage CPBA overestimated or underestimated 25(OH)D concentrations predicated on the prevailing metabolite present in patients’ sera.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2005.064956

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 239

Metadata

Authors
Lensmeyer, G. L., Wiebe, D. A., Binkley, N., & Drezner, M. K.
Venue
Clinical Chemistry
Published
2006-06-01
Volume
52
Issue
6
Pages
1120-1126
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2111673931
Cited by
239
References
0
FWCI
10.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: HPLC Method for 25-Hydroxyvitamin D Measurement: Comparison with Contemporary Assays. https://app.cochat.ai/papers/10.1373/clinchem.2005.064956
The paper
Lensmeyer, G. L., Wiebe, D. A., Binkley, N., & Drezner, M. K. (2006). HPLC Method for 25-Hydroxyvitamin D Measurement: Comparison with Contemporary Assays. Clinical Chemistry. https://doi.org/10.1373/clinchem.2005.064956

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.