Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 187

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Nanodiagnostics: A New Frontier for Clinical Laboratory Medicine

Azzazy, Hassan ME, Mansour, Mai MH, Kazmierczak, Steven C · 2006 · Clinical Chemistry

Abstract

Background: The use of nanotechnologies for diagnostic applications shows great promise to meet the rigorous demands of the clinical laboratory for sensitivity and cost-effectiveness. New nanodiagnostic tools include quantum dots (QDs), gold nanoparticles, and cantilevers. QDs, which are the most promising nanostructures for diagnostic applications, are semiconductor nanocrystals characterized by high photostability, single-wavelength excitation, and size-tunable emission. QDs and magnetic nanoparticles can be used for barcoding of specific analytes. Gold and magnetic nanoparticles are key components of the bio-barcode assay, which has been proposed as a future alternative to the PCR. Methods: We examined articles published over the past 10 years investigating the use of QDs, gold nanoparticles, cantilevers, and other nanotechnologies in promising diagnostic applications. Results: Several nanodiagnostic assays have been developed, including a QD-based assay capable of detecting biotinylated prostate-specific antigen (PSA) at 0.38 ng/L, a bio-barcode assay capable of detecting 30 amol/L PSA in a 10-μL sample, and another able to detect 50 molecules of the Alzheimer marker amyloid β-derived diffusible ligand in 10 μL of cerebrospinal fluid. Conclusions: Nanodiagnostics promise increased sensitivity, multiplexing capabilities, and reduced cost for many diagnostic applications as well as intracellular imaging. Further work is needed to fully optimize these diagnostic nanotechnologies for clinical laboratory setting and to address the potential health and environmental risks related to QDs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2006.066654

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 187

Metadata

Authors
Azzazy, H. M., Mansour, M. M., & Kazmierczak, S. C.
Venue
Clinical Chemistry
Published
2006-07-01
Volume
52
Issue
7
Pages
1238-1246
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2074967496
Cited by
187
References
1
FWCI
6.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Nanodiagnostics: A New Frontier for Clinical Laboratory Medicine. https://app.cochat.ai/papers/10.1373/clinchem.2006.066654
The paper
Azzazy, H. M., Mansour, M. M., & Kazmierczak, S. C. (2006). Nanodiagnostics: A New Frontier for Clinical Laboratory Medicine. Clinical Chemistry. https://doi.org/10.1373/clinchem.2006.066654

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.