Toward Standardization of Cardiac Troponin I Measurements Part II: Assessing Commutability of Candidate Reference Materials and Harmonization of Cardiac Troponin I Assays
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Cardiac tropoin I (cTnI) measurements show an approximately 20- to 40-fold difference between assays, and better standardization and harmonization are needed. Toward this goal, the AACC cTnI Standardization Committee collaborated with the National Institute of Standards and Technology (NIST) in an earlier study to select 2 candidate reference materials (cRMs). METHODS: Two troponin cRMs, a troponin C-troponin I-troponin T (CIT) complex from human heart tissue and a CIT complex from recombinant technology, were supplied to NIST for assessment of composition and purity, and cTnI value assignment. These cRMs and 6 cTnI-positive human serum pools were shipped to manufacturers of 15 cTnI assays. Commutability of the materials was examined by determining the numerical relationship for the cRM preparations between each manufacturer-specified field method and each of the other 14 field methods. These relationships were then compared with the corresponding numerical relationships for the human serum pools. Harmonization of methods was accomplished by determining regression parameters relative to the analytical system yielding values closest to the median for each serum pool. These regression parameters were used to recalculate pool values to harmonize the assays. Interassay CVs before and after harmonization were determined. RESULTS: Characterization of the CIT and CI cRMs showed that these materials were of specified composition. The proportion of cTnI methods that demonstrated commutability for the CIT cRM was 45%; for the CI cRM, 39% of methods demonstrated commutability. Interassay cTnI variability for the field methods ranged from 82% to 97%, median 88%. After harmonization, variability of the serum pools for the cTnI methods was decreased to between 9.0% and 23%, median 15.5%. CONCLUSIONS: The proportion of methods demonstrating commutability was too low for use as a common calibrator for the cTnI field methods. However a simple strategy using serum pools can improve harmonization of field cTnI methods by more than 5-fold. The CIT cRM was selected by the AACC cTnI standardization committee, and a new lot has been classified as the cTnI certified reference material Standard Reference Material 2921 by NIST.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Passing, H., & Bablok, W. (1983) · cclm · doi:10.1515/cclm.1983.21.11.709 · Cited by 1,513 · cited 1×
“The black fill represents variability of the field methods; the grey fill represents variability after alignment of the field methods with the common comparison method (16); the open fill represents variability after calibration of the methods with cRMCIT.”
MethodLabugger, R., Organ, L., Collier, C., Atar, D., & Van Eyk, J. E. (2000) · Circulation · doi:10.1161/01.cir.102.11.1221 · Cited by 315
Degradation of cardiac troponin I: implication for reliable immunodetection
Katrukha, A. G., Bereznikova, A. V., Filatov, V. L., Esakova, T. V., Kolosova, O. V., Pettersson, K., Lövgren, T., Bulargina, T. V., Trifonov, I. R., Gratsiansky, N. A., et al. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.12.2433 · Cited by 232 · cited 3×
“The nature of cTnI complicates analytical (immunoassay) measurement because the molecule may be found as binary and ternary complexes and free, oxidized, reduced, and phosphorylated forms (9, 10).”
BackgroundInfluential
Cited by
for the IOF-IFCC Bone Marker Standards Working Group, Vasikaran, S., Eastell, R., Bruyère, O., Foldes, A. J., Garnero, P., Griesmacher, A., McClung, M., Morris, H. A., Silverman, S., et al. (2011) · Osteoporosis International · doi:10.1007/s00198-010-1501-1 · Cited by 1,212
“However a considerable body of knowledge has been developed on these issues in recent years [156].”
BackgroundRecommendations for the use of cardiac troponin measurement in acute cardiac care
Thygesen, K., Mair, J., Katus, H., Plebani, M., Venge, P., Collinson, P., Lindahl, B., Giannitsis, E., Hasin, Y., Galvani, M., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq251 · Cited by 628
Wu, A. H. B., Christenson, R. H., Greene, D. N., Jaffe, A. S., Kavsak, P. A., Ordonez-Llanos, J., & Apple, F. S. (2018) · Clinical Chemistry · doi:10.1373/clinchem.2017.277186 · Cited by 450
Self-citationNACB Writing Group Members, Apple, F. S., Jesse, R. L., Newby, L. K., Wu, A. H. B., & Christenson, R. H. (2007) · Circulation · doi:10.1161/circulationaha.107.182881 · Cited by 300
Self-citationNACB WRITING GROUP MEMBERS, Apple, F. S., Jesse, R. L., Newby, L. K., Wu, A. H. B., Christenson, R. H., NACB COMMITTEE MEMBERS, Christenson, R. H., Apple, F. S., Cannon, C. P., et al. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.084715 · Cited by 258
Self-citation
Metadata
- Authors
- Christenson, R. H.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-09-01
- Volume
- 52
- Issue
- 9
- Pages
- 1685-1692
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2170594234
- Cited by
- 94
- References
- 3
- FWCI
- 6.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.