Preanalytic Error Tracking in a Laboratory Medicine Department: Results of a 1-Year Experience
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Remarkable advances in technology, automation, and testing procedures have produced radical changes in laboratory organization, granting major precision and accuracy of test results. Nevertheless, errors occurring within the whole testing process still influence the quality of laboratory performance. There is heterogeneous information on the error rate within the whole laboratory testing process (from 0.1% to 9.3%) (1). Moreover, the frequencies and types of mistakes differ between one facility and another and between one time period and another (2). Process analysis has demonstrated that laboratory errors occur primarily in the preanalytic phase, influencing patient outcomes and costs (1)(2)(3). Compliance with systems of quality management, such as certification and accreditation, requires accurate procedures for identifying the processes that are more susceptible to errors (4). The Laboratory Medicine Department of the University Hospital of Verona is a laboratory service providing stat and routine tests for clinical chemistry, hematology, coagulation, and immunology, serving an area with a population of 270 000 inhabitants. The laboratory serves a hospital with 750 beds and specialized care units. Inpatient phlebotomies are performed by clinical department staff, whereas blood specimens from outpatients are collected on site by laboratory personnel. After implementation of the new ISO accreditation guidelines, since October 2004 the laboratory staff has been trained to identify and systematically record each error encountered within the global testing process, particularly preanalytic mistakes. Venous blood samples for routine clinical chemistry (lithium heparin gel tubes), hematologic (EDTA tubes), coagulation (buffered sodium citrate tubes), electrophoresis, specific protein, and immunology testing (serum gel tubes) were considered unsuitable according to the following accepted criteria (5)(6): inappropriate volume (excess or deficit in the volume required to perform the analysis), wrong or missing patient identification, inappropriate container, visible hemolysis after centrifugation, clotting, and contamination from infusion route. The laboratory staff was provided with a notebook in which numbers of tubes and errors were recorded daily, and the quality referent of our laboratory systematically discussed and reviewed data on a weekly basis. From October 2004 to September 2005, a total of 423 075 routine venous blood specimens (71 922 from outpatients; 17%) were received in the 5 more representative sections of our laboratory (130 806 for clinical chemistry testing, 113 699 for hematologic testing, 61 301 for coagulation testing, 59 403 for electrophoresis and specific protein testing, and 57 866 for immunology testing). According to the above specified criteria, 3154 (0.74%) preanalytic errors were identified and recorded in the 1-year observational period (Table 11 ). Errors were related to samples in which they were relevant. In agreement with earlier data (1)(7), we observed a significant difference in the error rate between inpatients and outpatients (0.82% vs 0.37%; χ2 test, P <0.001). The most common mistakes could be traced to incorrect procedures for sample collection, including hemolysis and clotting. The prevalences of other types of errors were rather different between specimens collected from inpatients and outpatients. In particular, insufficient volume was a prevailing cause of unsuitable specimens for inpatient samples, whereas the prevalence of inappropriate containers was particularly high for outpatient specimens. Current data on laboratory error rates are mixed (1). In a survey on outpatient phlebotomy success, most unsuitable samples resulted from hemolysis (18.1%), insufficient quantity (16.0%), and clotting (13.4%) (5). These data are comparable to those provided by additional investigations, which confirm that problems directly related to specimen collection are the first causes of preanalytic errors, especially hemolyzed, clotted, insufficient, and incorrect samples (1)(7)(8)(9). This investigation represents a logical extension of previous analyses focused on laboratory errors identified after collection of clinically questionable results in stat departments for a shorter period of time (2)(8) or involving limited areas of laboratory testing, such as clinical chemistry (7) and hematology(9). Additionally, we included a systematic approach for error identification, extending the analysis to either inpatient or outpatient specimens for routine laboratory testing. Results were finally related to the total number of specimens received, rather than to the tests ordered. Nevertheless, the substantial difficulty in linking preanalytic quality improvements to patient outcome might be a drawback of this investigation (4)(10). The magnitude of medical errors requires the introduction of comprehensive reporting systems, encompassing mistakes that fall within the whole diagnostic proces
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bonini, P., Plebani, M., Ceriotti, F., & Rubboli, F. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.5.691 · Cited by 850
Cited by
Elimination of the venous stasis error for routine coagulation testing by transillumination
Lima-Oliveira, G., Salvagno, G. L., Lippi, G., Montagnana, M., Scartezini, M., Picheth, G., & Guidi, G. C. (2011) · Clinica Chimica Acta · doi:10.1016/j.cca.2011.04.008 · Cited by 38
Self-citationInfluence of primary sample mixing on routine coagulation testing
Lippi, G., Salvagno, G. L., Montagnana, M., & Guidi, G. C. (2007) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0b013e32828621a0 · Cited by 18
Self-citationBostic, G., Thompson, R., Atanasoski, S., Canlas, C., Ye, H., Kolins, M., & Smith, M. D. (2015) · Laboratory Medicine · doi:10.1309/lma4wyn3xfukelbd · Cited by 14
Metadata
- Authors
- Lippi, G., Bassi, A., Brocco, G., Montagnana, M., Salvagno, G. L., & Guidi, G. C.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-07-01
- Volume
- 52
- Issue
- 7
- Pages
- 1442-1443
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2144213167
- Cited by
- 114
- References
- 1
- FWCI
- 4.12
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.