Macro Thyrotropin-IgG Complex Causes Factitious Increases in Thyroid-Stimulating Hormone Screening Tests in a Neonate and Mother
Open accessThe DOI matches its Crossref record.
Abstract
We read with interest the case reported by Newman et al. (1) of factitious neonatal hyperthyrotropinemia, and we noted that the authors were unable to identify the maternally transmitted interfering substance. We report a similar case in which we demonstrated that the interference was caused by the presence of a macro thyrotropin-IgG complex (macroTSH). Routine neonatal screening performed 7 days after an uncomplicated delivery in a full-term infant revealed a blood spot thyroid-stimulating hormone (TSH) of 213 mIU/L (Perkin-Elmer DELFIA assay, reference range <10 mIU/L). The neonate was clinically euthyroid, and repeat serum thyroid function tests at 10 days (Roche Elecsys) confirmed the increased serum TSH (826 mIU/L, reference interval 0.27–4.20 mIU/L) but showed a free thyroxine (FT4) concentration within the reference interval, at 17.2 pmol/L (reference interval 12.0–22.0 pmol/L). The mother was also clinically euthyroid, and her thyroid function tests also showed increased TSH (308 mIU/L, reference interval 0.27–4.20 mU/L) and an FT4 of 13.5 pmol/L, within the reference interval of 12.0–22.0 pmol/L, both measured with the Roche Elecsys. The discrepant thyroid function test results and the absence of clinical symptoms prompted investigations for interference in the TSH assay. In the mother’s serum TSH, results varied with different assays (reference intervals are in parentheses); Bayer Centaur, 4.0 mIU/L (0.35–5.5 mIU/L); DPC Immulite, 16 mIU/L (0.4–4.0 mIU/L); Roche Elecsys, 308 mIU/L (0.27–4.2 mIU/L), and Delfia 146mIU/L (0.4–4.0 mIU/L). With the Immulite and Delfia assays, TSH values did not dilute linearly (other systems were not tested). A 5-fold dilution of maternal serum in TSH-free diluent (provided by the manufacturers) increased estimated serum TSH concentration to 58.1 and 225 mIU/L, respectively. With the Elecsys assay, adsorption with protein G-Sepharose (Sigma) removed 99.6% (routine <1%) of the TSH immunoreactivity, indicating interference involving an IgG antibody. Gel filtration chromatography of serum from the mother and infant, performed with a 40-cm Sephacryl S-300 column (Pharmacia), showed that the majority of the TSH immunoreactivity in the Elecsys assay eluted in a peak with molecular mass consistent with a TSH-IgG complex (Fig. 11 ). This peak was not present on chromatography of serum after adsorption with protein G-Sepharose. Incubation of maternal serum with serum from a patient with hypothyroidism and increased TSH, followed by chromatography, showed an increase in the concentration of macroTSH (Fig. 11 ), confirming the presence of excess anti-TSH antibodies. Serum TSH in the neonate remained increased (>100 mIU/L) at 3 months of age, but an accurate result after dilution was not obtained. It is possible that the macroTSH in the neonate resulted from maternal transmission of the anti-TSH antibody, but the mother refused further investigations on herself and the infant, and we were not able to determine whether the macroTSH persisted. In conclusion, we report a case in which macroTSH caused a false-positive screening test result for congenital hypothyroidism. In their case report, Newman et al. (1) emphasized that increased serum TSH results detected in screening programs for neonatal hypothyroidism should be confirmed with repeat TSH and FT4 measurements and investigation of discrepant results. It has also been recommended that maternal thyroid function tests be carried out in these cases (2). MacroTSH has been described in a mother and her neonates by Tamaki et al. (3), and we report our case to raise awareness of this particular form of assay interference and to illustrate the value of gel filtration chromatography in identifying interference from macro forms of peptide hormones (4)(5)(6) and in distinguishing this form of interference from that caused by heterophile antibodies. Gel filtration chromatography of serum TSH. Gel filtration chromatography of serum TSH in a control patient with increased TSH caused by hypothyroidism, Δ−Δ; in the neonate, ○−○; and in the mother before, •−• and after incubation with serum from a control with increased TSH, ▴−▴. The peak elution volumes for endogenous serum prolactin, albumin, and IgG are shown as markers of molecular mass.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Interferences With Thyroid Function Immunoassays: Clinical Implications and Detection Algorithm
Favresse, J., Burlacu, M.-C., Maiter, D., & Gruson, D. (2018) · Endocrine Reviews · doi:10.1210/er.2018-00119 · Cited by 258
What should be done when thyroid function tests do not make sense?: Atypical thyroid function tests
Gurnell, M., Halsall, D. J., & Chatterjee, V. K. (2011) · Clinical Endocrinology · doi:10.1111/j.1365-2265.2011.04023.x · Cited by 88
Self-citationMacro-Thyrotropin: A Case Report and Review of Literature
Loh, T. P., Kao, S. L., Halsall, D. J., Toh, S.-A. E. S., Chan, E., Ho, S. C., Tai, E. S., & Khoo, C. M. (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2011-3490 · Cited by 84
“The Roche and Perkin-Elmer DELFIA assays are more sensitive to macro-TSH interference (reporting higher spuriously elevated TSH results) (19–22), whereas the Advia Centaur assay is least sensitive to such interference (reporting lower spuriously elevated TSH results) (2, 4, 21, 22).”
BackgroundMethodSelf-citation
Metadata
- Authors
- Halsall, D. J., Fahie-Wilson, M. N., Hall, S. K., Barker, P., Anderson, J., Gama, R., & Chatterjee, V. K.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-10-01
- Volume
- 52
- Issue
- 10
- Pages
- 1968-1969
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2127650821
- Cited by
- 43
- References
- 0
- FWCI
- 1.21
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Macro Thyrotropin-IgG Complex Causes Factitious Increases in Thyroid-Stimulating Hormone Screening Tests in a Neonate and Mother. https://app.cochat.ai/papers/10.1373/clinchem.2006.071050
- The paper
- Halsall, D. J., Fahie-Wilson, M. N., Hall, S. K., Barker, P., Anderson, J., Gama, R., & Chatterjee, V. K. (2006). Macro Thyrotropin-IgG Complex Causes Factitious Increases in Thyroid-Stimulating Hormone Screening Tests in a Neonate and Mother. Clinical Chemistry. https://doi.org/10.1373/clinchem.2006.071050
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.