Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 175

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Technical and Diagnostic Performance of 6 Assays for the Measurement of Citrullinated Protein/Peptide Antibodies in the Diagnosis of Rheumatoid Arthritis

Open access
Coenen, Dries, Verschueren, Patrick, Westhovens, René, Bossuyt, Xavier · 2007 · Clinical Chemistry

Abstract

Background: Several anticitrullinated protein/peptide antibodies (ACPA) assays have been reported to be of diagnostic value for rheumatoid arthritis (RA). We evaluated the technical performance and diagnostic accuracy of 6 ELISAs for the detection of antibodies to citrullinated protein/peptide antigens. Methods: ACPA were determined in 298 serum samples using 6 commercially available ACPA assays. One hundred two samples were from RA patients, including patients with early and established RA, and 196 were from controls, including patients with psoriatic arthritis, connective tissue diseases, organ-specific autoimmune diseases, and a group of consecutive patients for whom a rheumatologist ordered anticyclic citrullinated peptide (CCP) antibodies. The ELISA reagent sets under study were Citrullinated Protein Antibodies (Genesis), Anti-MCV (Orgentec), Immunoscan RA (Euro-Diagnostica), Anti-CCP IgG ELISA (Euroimmun), EliA™ CCP (Phadia), and Quanta Lite™ CCP3 IgG ELISA (Inova). Technical performance (imprecision, linearity, correlation, and agreement) and diagnostic accuracy (sensitivity and specificity) were compared. Results: Variable technical performance was noted among the different ACPA assays, with some assays displaying poor reproducibility and bad linearity. ACPA results were well correlated among assays with the same antigen specificity, but the numerical values reported for each assay differed widely. Using cutoff values proposed by the manufacturer, diagnostic sensitivities ranged between 69.6% and 77.5% and specificities between 87.8% and 96.4%. The areas under the ROC curves were comparable among the different assays. Conclusions: Overall diagnostic performance of ACPA assays is comparable among the different assays, but standardization is needed. For some assays, analytical characteristics could be improved.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2006.078063

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 175

Metadata

Authors
Coenen, D., Verschueren, P., Westhovens, R., & Bossuyt, X.
Venue
Clinical Chemistry
Published
2007-03-01
Volume
53
Issue
3
Pages
498-504
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2153299884
Cited by
175
References
2
FWCI
10.76
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Technical and Diagnostic Performance of 6 Assays for the Measurement of Citrullinated Protein/Peptide Antibodies in the Diagnosis of Rheumatoid Arthritis. https://app.cochat.ai/papers/10.1373/clinchem.2006.078063
The paper
Coenen, D., Verschueren, P., Westhovens, R., & Bossuyt, X. (2007). Technical and Diagnostic Performance of 6 Assays for the Measurement of Citrullinated Protein/Peptide Antibodies in the Diagnosis of Rheumatoid Arthritis. Clinical Chemistry. https://doi.org/10.1373/clinchem.2006.078063

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.