CoChat

Variability in the Relationship between Mean Plasma Glucose and HbA1c: Implications for the Assessment of Glycemic Control

Kilpatrick, Eric S, Rigby, Alan S, Atkin, Stephen L · 2007 · Clinical Chemistry
Cited by 96

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: Previous studies have shown a single linear relationship between mean plasma glucose (MPG) and hemoglobin A1c (HbA1c). We examined the relationship in different treatment groups of patients with type 1 diabetes participating in the Diabetes Control and Complications Trial (DCCT). Methods: Seven-point glucose profiles (premeal, postmeal, and bedtime) and HbA1c were measured quarterly during the DCCT. We studied measurements from (a) intensively treated patients at study commencement, (b) intensively treated patients after stabilization of their glycemia (from 6 months onward), and (c) conventionally treated patients from 6 months onward. Only complete glucose profile and HbA1c pairings were considered (n = 589, 11 483, and 11 855, respectively). Results: From 6 months into the trial, conventionally treated patients had consistently higher MPG concentrations than intensively treated patients at any given HbA1c value (mean difference, 1.6 mmol/L at 7% HbA1c, increasing to 2.8 mmol/L at 11% HbA1c). Similarly, at the same HbA1c, the MPG of intensively treated patients at baseline was higher than in the same individuals after 6 months of intensive treatment (1.2 mmol/L difference at 7% HbA1c, increasing to 4.6 mmol/L at 11% HbA1c). Conclusions: The relationship between MPG and HbA1c is not constant but differs depending on the glycemic control of the population being studied. Having lower mean glucose at the same HbA1c may help explain why intensive DCCT treatment appeared intrinsically linked to both increased hypoglycemia and decreased microvascular complications compared with conventional treatment. These findings may also have implications for expressing HbA1c as mean blood glucose equivalent.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2006.079756

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 96

Metadata

Authors
Kilpatrick, E. S., Rigby, A. S., & Atkin, S. L.
Venue
Clinical Chemistry
Published
2007-05-01
Volume
53
Issue
5
Pages
897-901
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2105677350
Cited by
96
References
3
FWCI
7.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Variability in the Relationship between Mean Plasma Glucose and HbA1c: Implications for the Assessment of Glycemic Control. https://app.cochat.ai/papers/10.1373/clinchem.2006.079756
The paper
Kilpatrick, E. S., Rigby, A. S., & Atkin, S. L. (2007). Variability in the Relationship between Mean Plasma Glucose and HbA1c: Implications for the Assessment of Glycemic Control. Clinical Chemistry. https://doi.org/10.1373/clinchem.2006.079756

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.