Diagnostic Accuracy of Blood Lactate-to-Pyruvate Molar Ratio in the Differential Diagnosis of Congenital Lactic Acidosis
The DOI matches its Crossref record.
Abstract
Background: Although the blood lactate-to-pyruvate (L:P) molar ratio is used to distinguish between pyruvate dehydrogenase deficiency (PDH-D) and other causes of congenital lactic acidosis (CLA), its diagnostic accuracy for differentiating between these 2 types of CLA has not been evaluated formally. Methods: We conducted a retrospective study of all patients followed for mitochondrial diseases between 1985 and 2005 in a tertiary care pediatric hospital. Results: At the recommended cut point of ∼25, individual median L:P ratio demonstrated low sensitivity and specificity (77% and 91%, respectively) for differentiating between patients with enzymatically proven PDH-D (n = 11) and those with mitochondrial disease but normal pyruvate dehydrogenase (PDH) activity (non-PDH; n = 35). We observed a strong positive association between L:P ratio and blood lactate in non-PDH CLA, whereas this association was weak in PDH-D CLA. Consequently, patient classification based on median L:P ratio showed improved diagnostic accuracy at higher lactate concentrations: for lactate <2.5 mmol/L the area under the ROC curve was not statistically different from 0.5 (P = 0.3), whereas it was statistically different for lactate >2.5 mmol/L. In the 2.5 to 5.0 mmol/L lactate category, the sensitivity and specificity at an optimal cut point of 18.4 were 93% (95% CI, 77%–99%) and 71% (95% CI, 20%–96%), respectively; for lactate >5.0 mmol/L, with an optimal cut point of 25.8, sensitivity and specificity were 96% (95% CI, 77%–99%) and 100% (95% CI, 59%–100%), respectively. Conclusion: Usefulness of the L:P ratio for differentiating non-PDH and PDH-D types of CLA increases at higher lactate concentrations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Parikh, S., Goldstein, A., Koenig, M. K., Scaglia, F., Enns, G. M., Saneto, R., Anselm, I., Cohen, B. H., Falk, M. J., Greene, C., et al. (2015) · Genetics in Medicine · doi:10.1038/gim.2014.177 · Cited by 607
The in-depth evaluation of suspected mitochondrial disease
Haas, R. H., Parikh, S., Falk, M. J., Saneto, R. P., Wolf, N. I., Darin, N., Wong, L.-J., Cohen, B. H., & Naviaux, R. K. (2008) · Molecular Genetics and Metabolism · doi:10.1016/j.ymgme.2007.11.018 · Cited by 365
Mitochondrial medicine in the omics era
Rahman, J., & Rahman, S. (2018) · The Lancet · doi:10.1016/s0140-6736(18)30727-x · Cited by 283
Biagi, S., Ghimenti, S., Onor, M., & Bramanti, E. (2012) · Biomedical Chromatography · doi:10.1002/bmc.2713 · Cited by 110
Diagnosis of mitochondrial myopathies
Milone, M., & Wong, L.-J. (2013) · Molecular Genetics and Metabolism · doi:10.1016/j.ymgme.2013.07.007 · Cited by 89
Metadata
- Authors
- Debray, F.-G., Mitchell, G. A., Allard, P., Robinson, B. H., Hanley, J. A., & Lambert, M.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-05-01
- Volume
- 53
- Issue
- 5
- Pages
- 916-921
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2116261986
- Cited by
- 135
- References
- 0
- FWCI
- 2.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic Accuracy of Blood Lactate-to-Pyruvate Molar Ratio in the Differential Diagnosis of Congenital Lactic Acidosis. https://app.cochat.ai/papers/10.1373/clinchem.2006.081166
- The paper
- Debray, F.-G., Mitchell, G. A., Allard, P., Robinson, B. H., Hanley, J. A., & Lambert, M. (2007). Diagnostic Accuracy of Blood Lactate-to-Pyruvate Molar Ratio in the Differential Diagnosis of Congenital Lactic Acidosis. Clinical Chemistry. https://doi.org/10.1373/clinchem.2006.081166
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.